Question about Greenlee Dm-20 Digital Multimeter

1 Answer

How to set meter to micro amps

How to test micro amps

Posted by Anonymous on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 2,113 Answers

I see the greek letter micro where your dial says 2,000 (micro) amps. 2,000 micro amps = .002 amps your 200 mA setting = .2 amps

Posted on Nov 26, 2013

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

WHY DOES TOP ICEMAKER FAN KEEP FREEZING


The fan usually stops working due to ice obstruction when the defrost terminator has gone out and u get ice build up? u can check the terminator with a multi meter for continuity but do not check at room temperature. stick the terminator in cup of ice water for 20 minutes then check it for continuity, should be closed when cold and open at room temperature.
May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS .

check the cold control thermostat with a meter for both OHMS and volts ( VOLTS is a live test with fridge plugged in so be careful) It must show 110 volts. An open or thermostat that reads infinity will not allow the proper cooling and defrosting cycles to operate and may in fact stop anything from happening as if there is no power to the unit?
ALSO CHECK THE AIR FLOW VENT SYSTEM At times it can get stuck to far closed or open. Some units feature a digital electric adjusting vent system while others are manually set. Check for any ice build up or other obstruction in the vent damper, see if u can manually open or close it. Some times when u have the settings set to the highest it closes off one area while allowing to much cold air flow to the other area!







Apr 08, 2015 | Refrigerators

1 Answer

How to get out of the cooling off mode


check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Mar 30, 2015 | Whirlpool Refrigerators

1 Answer

Defrost button is not working what can i do?


May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS .
Lastly check the cold control thermostat with a meter for both OHMS and volts ( VOLTS is a live test with fridge plugged in so be careful)

ALSO CHECK THE AIR FLOW VENT SYSTEM

Feb 21, 2015 | Samsung Refrigerators

1 Answer

Reset the defrost timer


to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..


Dec 17, 2014 | Kenmore Refrigerators

1 Answer

Kenmore refrigerator freezing 106.56534400


no fan or air circulation:

AT TIMES The fan usually stops working due to ice obstruction when the defrost terminator has gone out and u get ice build up? u can check the terminator with a multi meter for continuity but do not check at room temperature. stick the terminator in cup of ice water for 20 minutes then check it for continuity, should be closed when cold and open at room temperature.
May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS .

Lastly check the cold control thermostat with a meter for both OHMS and volts ( VOLTS is a live test with fridge plugged in so be careful) It must show 110 volts. An open or thermostat that reads infinity will not allow the proper cooling and defrosting cycles to operate and may in fact stop anything from happening as if there is no power to the unit?

ALSO CHECK THE AIR FLOW VENT SYSTEM At times it can get stuck to far closed or open. Some units feature a digital electric adjusting vent system while others are manually set. Check for any ice build up or other obstruction in the vent damper, see if u can manually open or close it. Some times when u have the settings set to the highest it closes off one area while allowing to much cold air flow to the other area!










Aug 17, 2014 | Kenmore Refrigerators

1 Answer

How do i start a manual defrost for a RF267


the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Jun 25, 2014 | Samsung Refrigerators

1 Answer

Samsung forced defrost


the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Jun 25, 2014 | Samsung RS2556 Side by Side Refrigerator

1 Answer

How do I defrost my samsung rf215


May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS .

Apr 26, 2014 | Samsung Refrigerators

1 Answer

I have a 2008 Ford Ranger with a good battery, good connections, good alternator, etc. I have been trying to,figure out why the battery is draining overnight only. This happened twice and both times


Switch your Digital Multi meter to DC AMPs. Amps is usually indicated by an "A" on the Multi meter Switch. AC is usually shown as a "~" symbol and DC shown as a "-" symbol. You usually have to move the multi meter positive lead to a separate socket on the multi meter to check for amps. Sometimes there are 2 sockets, (a high range and a low range). Always test on the highest setting first. For example: High setting on your multi meter may be 10 Amp. Test on the 10 Amp setting first, then if the current drawn is less than your Multi meter's (low setting) move to that setting and keep testing. For example: On my multi meter the low setting is 0.3 Amps. Also indicated as 300mA (mA x 1000 = A).

Remove the battery's positive cable.

Connect the multi meter's positive probe to the battery's positive post while simultaneously holding the negative probe from the multi meter up in the air, to keep it away from anything metallic.

Place the negative probe of the multi meter on the end of the removed positive cable to complete the circuit.

That's right, you're putting a negative on a positive, but its ok, because if the drain is severe enough, you're most likely to blow a fuse or two, which will identify the problem area.

Above I said to remove the positive battery cable because that is the way I do it. You can do the same test with the negative battery cable removed. In fact for you that may be a better way to do the test, because there would be no way for any electrical issues to occur by accidently grounding the negative probe from the multi meter. i hope you understand what I'm saying here.

Mar 27, 2014 | 2008 Ford Ranger

1 Answer

Roper Microwave (mhe14xmq dec. 2003) trips breaker...


you might have to reset your your power settings on the micro.

Sep 21, 2008 | Roper MHE14XKB Microwave Oven

Not finding what you are looking for?
Greenlee Dm-20 Digital Multimeter Logo

Related Topics:

83 people viewed this question

Ask a Question

Usually answered in minutes!

Top Greenlee Measuring Tools & Sensors Experts

Vuk B

Level 3 Expert

678 Answers

Brad Brown

Level 3 Expert

15478 Answers

Tom Chichester

Level 3 Expert

33326 Answers

Are you a Greenlee Measuring Tool and Sensor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...