Question about Intermatic & Indoor/Outdoor Rain Tight Timer

1 Answer

T101 clock motor goes bad after 1 year for 4 years i

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Intermatic Master
  • 5,245 Answers

Clean up timer with compressed air, and a bit of WD40.
http://waterheatertimer.org/Photos-of-WH40-timer.html#remove-dial
Call Intermatic... most things have 1 year limited warranty... most clock motors last more than 10-20 years.

Gene
h

Posted on Nov 23, 2013

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My Intermatic T101 has power going to it and the clock works normally. But when the clock trips the switching lever to ON or I manually turn it to on, it does not put out power. Is there any sort of fuse...


There is no fuse inside the T101.
If timer clock motor is working correctly, then 120Volt circuit is fine up to the timer.
Unknown if this is new installation , or old installation that stopped working.
Wiring might be bad, such that line and load wires are reversed.
Or light bulb might be bad.
Copy following links to help narrow down problem:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html
http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timers.html

Dec 13, 2011 | Intermatic T101 - 24 Hr. Dial Time Switch...

1 Answer

I need installation or wiring diagram for Timer Intermatic T101


Copy following link for 120Volt T101 timer wiring options:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Nov 29, 2011 | Home

1 Answer

Timer not working on 4000 series, think its 4014 single pole single switch for pool pump. pump turns on when manually turn switch on but timer does not move. I feel the normal resistance and can move the...


1) If circuit breaker is not tripped or shorted, then timer clock motor has probably gone bad.

2) Some places still sell paragon timers, depending on model number.
But model number given is for 240Volt timer.

3) The clock motor is not available that I can find.
Paragon is no longer making the 4000 series timers or parts
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

4) Model number given does not match wiring terminals shown in manual.
4014 is DPST 240Volt timer with 4 wiring terminals labeled 1 2 3 4.
http://waterheatertimer.org/pdf/Paragon-4000-series.pdf

5) Paragon 4000 series timer with terminals 1 2 3 is 120Volt timer.

6) Replace 120Volt timer with Intermatic T101 indoor timer or T101R outdoor timer.
Crossover wiring:
Paragon terminal 1 goes to Intermatic terminal 1
Paragon terminal 2 goes to Intermatic terminal 2
Paragon terminals 3 goes to Intermatic terminal A
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

7) Take a moment and rate answer:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Aug 29, 2011 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

My Tork 1101 24 hr timer has stopped working. I hear it running, but the clock will not turn. I have to turn it on and off manually for my pool pump. This happened 2 years ago, then the following year...


You might need $45 clock motor for for Tork 1101 120Volt.
http://www.frontierlighting.com/product.jsp?part=10431&process=search&show=&&gdftrk=gdfV22514_a_7c834_a_7c3267_a_7c10431

Open following link to identify timer and see replacement clock motor and trippers:
http://waterheatertimer.org/Tork-timers-and-manuals.html#1101

Intermatic crossover shows T101 timer replaces 120Volt Tork 1101.
Amazon sells new Intermatic timer for $45 with super shipping
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

Crossover wiring from Tork to Intermatic:
Black wire on Tork L and 1 connect to Intermatic terminal 1
White wires on Tork X connect to Intermatic terminal A
Black wire on Tork 2 connects to Intermatic terminal 2
http://waterheatertimer.org/How-to-wire-T104-Intermatuic-timer.html#T101

Add a comment for more help

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Jun 04, 2011 | Vacuums

1 Answer

Not keeping correct time


You posted under Paragon 4001-00 120Volt SPST timer

1) If timer is not keeping correct time, generally you need to buy new clock motor.
However Paragon is no longer making timers and parts, except for defrost timers.
4001-00 is not defrost timer.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000

2) You probably need to replace timer
Intermatic cross reference shows T101 timer is correct replacement.
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx

3) Amazon sells T101 for $43.
This price is a lot lower than trying to find somebody who has specific Paragon clock motor
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

4) Grainger and many other places sell T100 series replacement trippers and motors.
No worry about defunct product

5) Wiring for T101 appears below:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Cross-over wiring is as follows:
Paragon terminal 1 goes to T101 terminal 1
Paragon terminal 2 goes to T101 terminal 2
Paragon terminal 3 goes to T101 terminal A

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Jan 27, 2011 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

1 year old t101m timer stopped working. The manual on/off works but mechanical clock doesn't. Is there an easy fix or should I just repalce?


T101 dial is not working so the 125V clock motor needs to be replaced:
Grainger sells 125V T100 series clock motor:
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search

Timer mechanism releases from box with metal spring located inside top of box.
Clock motor is attached with 2 star screws.
Notice clock motor has plastic gears, but timer has metal gears.
Metal gears on timer mechanism last for many years.

Notice also that clock motor wires connect to terminals A and 1.
After installing new motor, tighten screws very tight against copper wire.

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, fixya expert speaks with you over phone while you work on timer.

Jan 05, 2011 | RTO Intermatic T101M Timer Mechanism Only...

1 Answer

The dial on the intermatic water heater timer is not rotating on it's own and is easy to turn in either direction-without pulling it out and setting the time. The unit is only 1 year old..Can I replace the...


You can replace clock motor on many Intermatic timers:
Snap mechanism loose using metal spring top inside box.
Tip mechanism out and get clock motor number off motor.
Google search specific clock motor number.

Aplus sells many clock motor:
http://www.aplussupply.com/intermatic/timermotors.htm
Electric supply online sells clock motors
http://www.electricsupplyonline.com/prod/intermatic-motors.php

Grainger carries inexpensive clock motors for T101, T103, T104 timers.
http://www.grainger.com/Grainger/timer-accessories/timers/electrical/ecatalog/N-8hi
T101 and T103 use 125v motor
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search
T104 uses 240v motor
http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK2?Pid=search

Dec 01, 2010 | Intermatic & Indoor/Outdoor Rain Tight...

1 Answer

Model T104P wiring instructions for 110volt motor


T104 timer is for 240 Volt circuits. It has internal 240V clock motor. Clock terminals and timer terminals are connected, so there is no way this timer can control 110V circuit.
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html

T101 timer is for 110V circuit.
T101 has 110V clock motor
Both white neutral wires = terminal A.
Black hot wire from breaker box = terminal 1
Black wire to load = terminal 2.
Grounds = green screw
Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;}
T103 timer is for 110V circuit
T103 has 110V clock motor
Both white neutral wires = terminal A.
Black hot wire from breaker box = terminal 3
Black hot wire to load = terminal 4
Grounds = green screw

T1905 timer is for 110V circuit.
T1905 has 110V clock motor
Both white neutrals = Clock terminal
Black hot from breaker = COM
Black to load = NO [load comes on when timer turns on]

Sep 21, 2010 | Intermatic & Indoor/Outdoor Rain Tight...

Not finding what you are looking for?
Intermatic & Indoor/Outdoor Rain Tight Timer  Logo

Related Topics:

25 people viewed this question

Ask a Question

Usually answered in minutes!

Top Intermatic Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5245 Answers

Jay Finke
Jay Finke

Level 3 Expert

1363 Answers

Hippy_dd

Level 2 Expert

112 Answers

Are you an Intermatic Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...