Question about Optimus Heating & Cooling

Open Question

Alarm on will not go off and heater will not come on

Posted by on

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Error code e63


E63
Intervention of auto-reset thermostat on the heater unit.

Possible fault Thermostat faulty (replace heater unit); Heater unit faulty; Wiring faulty; Electronic board faulty.

Machine Status/Action Disconnects the power supply to the heater unit. If the problem does not re-occur, the alarm is memorized and the cycle continues. If, after several attempts to restore power, the fault persists, alarm E62 is generated.

stolen right from google results

Jul 29, 2016 | Washing Machines

1 Answer

I dusted the bottom of my heater and now the alarm light comes on and the heater want come on.


unplug it and leave it unplugged for over 24 hours then try plugging it in again. if that doesn't do anything then you have knocked off, broken or damaged a sensor that allows the heater to function properly.

Dec 30, 2014 | Heating & Cooling

1 Answer

Why is my dryer beeping and showing E60?


24386410-hf2jxxovvq5cn05mugly0fcq-2-0.jpg

The last alarm code memorized can be displayed even if the appliance is in normal operating mode (e.g. while the drying programme is being performed): - Press (start/pause) and first option button simultaneously for at least 5 seconds: the display shows the last alarm.The alarm sequence continues to flash as long as the two buttons are held down.
The appliance continues the cycle while the alarm codes are being displayed. If the appliance is in programme selection mode, the options previously selected are stored in memory.

E60 is family fault code but after reading last alarm you will see exactly fault code (E61; E62; E63)

E61 - Insufficient heating (maximum time exceeded)
  • Heater unit faulty
  • Wiring faulty
  • NTC sensor incorrectly calibrated/out of position
  • Electronic board faulty
E62 - Power reley to heater unit faulty
  • Heater unit faulty
  • Wiring faulty
  • Electronic board faulty
E63 - Intervention of auto-reset thermostat on the heater unit
  • Thermostat faulty (replace heater unit)
  • Heater unit faulty
  • Wiring faulty
  • Electronic board faulty

Dado

May 10, 2014 | AEG T57800 Electric Dryer

1 Answer

Williams wall heater setting off co2 alarm


Then it may well need a service or check the alarm

Jan 01, 2014 | Williams (5009622) Ceramic Gas Wall...

1 Answer

When i turn the heater on it makes the alarm go off. what could be the problem


If its putting out carbon monoxide the heater is bad. Turn it off and call a heating company.

Nov 27, 2013 | Heating & Cooling

1 Answer

Alarm 01


Were you ever able to figure this problem out? I am getting the same thing and can't find anyone who knows anything about them.

Mar 11, 2013 | New Comfort ES1500 Energy Efficient...

1 Answer

Why does my Kozy World natural gas wall heater set off fire alarm system?


Most new heaters give off a smell or some light smoke which needs to be burnt off the first time it is used it may smoke , this may be why your alarm is going off , run it with a window open to remove smell etc .

Feb 12, 2013 | Heating & Cooling

4 Answers

Alarm light staying on.


I have the same problem. I removed the center panel on the back of the dish and found a fuse inside a white insulating sleeve. The fuse is open, preventing the current from reaching the heating coils. On the fuse it says 121 C. and 15 A.; I assume that it is designed to blow if the temp. of the dish exceeds 121 centigrade or the current exceeds 15 Amps. I don't see any reason to believe that either has happened so I suspect that these fuses just spontaneously fail. Now I just need to find a source for new ones. I wouldn't recommend jumping the fuse as it could lead to a fire.

Feb 22, 2008 | Heating & Cooling

3 Answers

When the alarm on the Patton Electric Heater sounds, whay does one do to fix that?


This heater was the determined cause of my total loss house fire. I thought the company would atleast help me find some where else to live, they seem to care. But, as of lately they are doing nothing.
I am told this heater-(prh11- 2008 model- purchased at walmart for about $27.00)
- Had wiring that wasn't up to standards
-1/10,000 units cause fires
-something wrong with the heating element-stops working
- wouldn't stand level
-heating coils
-fires like mine have happened to a few other people
This came directly from a person at Jarden corporation(aka patton-sunbeam)

Jan 05, 2008 | Patton Electric Patton PUH680-U Electric...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

26 people viewed this question

Ask a Question

Usually answered in minutes!

Top Optimus Heating & Cooling Experts

Mack Baxter

Level 3 Expert

381 Answers

L Pfaff
L Pfaff

Level 3 Expert

11573 Answers

kakima

Level 3 Expert

102366 Answers

Are you an Optimus Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...