Question about Pentair PUREX MINIMAX HEATER; THERMOSTAT, 60 CAPILLARY - 072022

Open Question

I have a purex triton 400 minimax plus indicator lights

Indicator lights show power and TSAT, AUX,BUT PRESSURE LIGHT AND HEAT LED ARE NOT WORKING HEATER WILL NOT TURN ON . COULDS THIS BE THE PRESSURE SWITCH

Posted by Anonymous on

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 246 Answers

SOURCE: minimax 400 heater not operational

what is ok on the water pressure? th heater need from 40 to 60 gpm in order to work properly clean the filter and let me know

Posted on Sep 11, 2009

  • 990 Answers

SOURCE: We need to know the BTU's of our older Purex

The 400 stands for 400'000 btu's

Posted on Nov 28, 2009

  • 990 Answers

SOURCE: Purex Triton Minimax 400 pool/spa heater not igniting

This sounds like you have a problem with your pilot. You can check this with a small mirror to see if their is a spark when you turn it on. If you have any soot build up on the pilot that will stop the spark and keep it from lighting also. If you have a short on your pilot wire this could be the problem also. I hope this helps, good luck.

Posted on Dec 12, 2009

  • 366 Answers

SOURCE: Purex Triton MiniMax Plus 400

if you have incoming power, you may have a bad transformer. those systems run on 24-28v. you can check from yellow wire to yellow wire coming off the transformer to see if you have anything coming out. must check wires coming out of the transformer to each other, it won't register if you check each one individually to ground. hope this helps...

Posted on Aug 18, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Purex triton minimax plus 400


You can call Pentair or go to their website: www.pentairpool.com

Then click on the "Find a Pentair Dealer Near You"
I saw about a dozen or so heater service centers in the Dallas area.

Oct 30, 2013 | Pool & Spa

1 Answer

Triton Purex minimax 400


dan i belive you have a faulty thermastat switch

Apr 01, 2012 | Pentair MiniMax CH Natural Gas Pool...

1 Answer

Purex Triton MiniMax Plus 400 power light is not turning on nor is unit. Checked for power going to unit and no fuses appear to be blown. Thoughts on what might be the issue? Thanks, Dan


if you have incoming power, you may have a bad transformer. those systems run on 24-28v. you can check from yellow wire to yellow wire coming off the transformer to see if you have anything coming out. must check wires coming out of the transformer to each other, it won't register if you check each one individually to ground. hope this helps...

Aug 11, 2011 | Pentair Minimax NT Heater

2 Answers

Purex triton powermax 400- gas ignites for a moment and then shuts off - basically cycles on and off for the spa. any idea to the problem?


This is usually either the Thermal Overload Cutoff (an inline fuse to prevent overheating) which costs $13.50 through poolcenter.com, or it is that you are not getting enough water pressure through the heater. There are sensors that will shut down the heater if there is not enough water flow. Is your filter clean so enough pressure/flow is happening?

Feb 15, 2010 | Pentair PUREX MINIMAX HEATER; THERMOSTAT,...

1 Answer

Triton minimax 400 pool heater won't ignite


Make sure the gas valve is set to on and thermostats are set properly. Check the pressure switch and high limits for continuity.Check wires for signs of damage, etc..

Jun 27, 2009 | Pentair PUREX MINIMAX HEATER; THERMOSTAT,...

1 Answer

Purex Triton Minimax 400 pool/spa heater not igniting


This sounds like you have a problem with your pilot. You can check this with a small mirror to see if their is a spark when you turn it on. If you have any soot build up on the pilot that will stop the spark and keep it from lighting also. If you have a short on your pilot wire this could be the problem also. I hope this helps, good luck.

Jun 05, 2009 | Pentair PUREX MINIMAX HEATER; THERMOSTAT,...

Not finding what you are looking for?
Pentair PUREX MINIMAX HEATER; THERMOSTAT, 60 CAPILLARY - 072022 Logo

Related Topics:

42 people viewed this question

Ask a Question

Usually answered in minutes!

Top Pentair Pool & Spa Experts

Pj Kiley
Pj Kiley

Level 1 Expert

21 Answers

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Pentair Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...