Question about LG LSC183VMA Split System Air Conditioner

Open Question

Lg mco7ahr code ch 32 - LG LSC183VMA Split System Air Conditioner

Posted by Anonymous on

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What does the code on the screen mean flashes between ch and 05 ?


CH 5 on these units indicates a communications error between the indoor and outdoor units. Generally, it will require a replacement outdoor board assembly to repair it. Lookup LG parts on the internet or ring them for your nearest Agent or parts. 800 243-0000

Oct 15, 2016 | LG Art Cool LA181CNW Split System Air...

1 Answer

LG air conditioner model number LMN095HVT units keep on flashing with error code CH 46 and with no response at all. How can I fix it? Thanks for your help in advance!


ERROR CH46:
Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor.

Sep 01, 2015 | LG Heating & Cooling

1 Answer

CH-10 error code in LG a/c.Modal-LBUC609RSA5


RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8

Dec 24, 2014 | LG Heating & Cooling

1 Answer

I have an LG mini split system, when I turn the unit on with the remote a code flashes on the wall unit 32 CH


do you have the owners manual? this is a fault code never worked on an LG mostly fujistu samsung

Oct 21, 2013 | Heating & Cooling

1 Answer

Lg dehumidifier ch 67 error


Thanks for the post by Posted by Bill L on Jul 14, 2012.
I decided to take a chance and order the new Sensor assembly $20.50 and install it in my LG LD651EBL Dehumidifier which was giving me ch 67 errors. Wala, it worked, the error code is gone and the dehumidifier is now working perfectly! Thanks

Jul 14, 2012 | LG LD651EBL Dehumidifier

2 Answers

LG dehumidifier LD451EGL with error code CH67


After cleaning the filter, i had to unplug the unit to clear the ch 67 error code before the unit would run again.

Apr 16, 2012 | LG Dehumidifiers

1 Answer

I have an LG ducted air conditioner and have an CH32 error. Can anyone tell me what this is? Thanks


CH-32 compressor discharge temperature too high. If over 105°C, check refrigerant charge.

Check and rectify the followings:
If over charged-release some gas./If less rpm of fan motor-replace capacitor./Condenser block-Clean it.

Jan 02, 2011 | LG Heating & Cooling

1 Answer

Lg ductless air conditioner is coming up with code ch 5


Communication between indoor PC and outdoor PC missed. Check that all connecting cables are good.

May 02, 2009 | LG Art Cool LA121CNP wall/window Air...

2 Answers

Ch 01


Change the sensor assembly and all will be fine, about $30 from Appliance Factory Parts on line store, about an hour to do, all that is needed is Phillips screw driver to take unit apart.

Nov 10, 2008 | LG LHD45EL Dehumidifier

Not finding what you are looking for?
LG LSC183VMA Split System Air Conditioner Logo

Related Topics:

32 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...