Question about Kipor Electrical Supplies

Open Question

Kipor generator P-05 error

Hi there I have a diesel kipor generator and it gave me error code p-05. Only a week ago it was running fine and nothing changed between then and now. On the owners manual it says that it can be the starter motor, but my generator is still relatively new. Can it be a fuse or something else that is relatively obvious? Regards Markus

Posted by on

  • Markus Otto
    Markus Otto Nov 27, 2013

    Thank you for your responses so far. It is a KDE19STA model. I have now checked all the fuses (all fine) and the oil level (also fine). On the underloading comment, I tried to put more load on it but it still does not want to start. After several attempts to start is, it suddenly moved (started to start for a split second, engine moved). Now every +- 5th attemp does the same? My first thought was that the battery does not have enough power to start the engine? Can this be true or what else can be the problem? Can I just use my car's battery as a test?

  • Markus Otto
    Markus Otto Nov 28, 2013

    Thank you for your responses so far. It is a KDE19STA model. I have now checked all the fuses (all fine) and the oil level (also fine). On the underloading comment, I tried to put more load on it but it still does not want to start. After several attempts to start is, it suddenly moved (started to start for a split second, engine moved). Now every +- 5th attemp does the same? My first thought was that the battery does not have enough power to start the engine? Can this be true or what else can be the problem? Can I just use my car's battery as a test?

×

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

CarlGehrke
  • 169 Answers

SOURCE: Problem with a kipor 12 ta generator

Hi,
I just guessing here but it could mean that the oil pressure is too low.
I'd check the oil level first, then look for the oil pressure switch and temporarily disconnect it.

Regards,
Carl

Posted on Feb 23, 2009

  • 342 Answers

SOURCE: Iam looking to download a manual for a Kipor KDE

looks very similar to the kde 6700 ta

Posted on Apr 04, 2010

  • 5603 Answers

SOURCE: My kipor KGE 1000Ti starts fine but after several

You may be UNDERLOADING the generator and it may be unstable with such a light load... see if it might behave running a heavier load... put a 100 watt light on it as a test,

Posted on Jul 25, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My kipor 7000 diesel generator is burning avr. Replaced avr don't last beyond few days. Can someone tell me cause


You need to run these tests in the video to see the state of the alternator. How to test your Electricity Generator AVR Brushes and Alternator on... With this info we can assist you further. :)

The Generator Guru Team

Jan 11, 2017 | Kipor Electrical Supplies

1 Answer

My Kipor KDE16STA3 shows p03 error after 15 min runing and shuts down after 3 sec.The voltage drops to 30,40 whta's happening?


[PDF]DIESEL GENERATING SET

www.kipor.com/upload/spec2011053011590766.pdf
3/KDE16STA3/ ..... P-03 Undervoltage: Indicating voltage higher (lower), the generator will self- braking. P-04 Generator ... KDE16STA3 KDE19STA KDE19STA3.

[PDF]2

www.kipor.com/upload/spec2011061109073968.pdf
P-03. Decrease load less than the related load, turn on the breaker. P-04. Replace the fuse of the same type. Check the circuit and inserter. Replace the starting ...

Oct 31, 2015 | Kipor Electrical Supplies

1 Answer

Why unit keeps shutting down after it starts.


Your question is general without specific details. Any one of many things will cause your generator engine to stop running.

Is this question about a Kipor KDE5000TA? If so, your generator is powered by a diesel engine. There are safety shut downs built into the generator to protect the generator head and engine. Do you have any fault codes showing on your control panel display screen? (Trouble codes P-01 through P-05 will be displayed if there's a detected fault)

If you have no fault codes, then you likely have a fuel problem. Do the obvious:
  1. Visually check the fuel level in your tank. DO NOT rely on your fuel gauge. It may be stuck or otherwise not working.
  2. If you have fuel, check your fuel filter. It may be clogged. If your fuel filter is good, you may have water contamination.
  3. Drain your tank and refill with fresh #2 diesel fuel. I use "Diesel 911" with a biocide to prevent water contamination and bacteria growth in my fuel.
  4. Make certain your fuel oil supply and return lines are clear, not leaking, and the fittings are tight.
I know I'm shotgunning, peppering the target. However, I don't have enough information to zero in on a specific area where the problem could be. Good luck!

Apr 26, 2015 | Kipor Generator Diesel Kde5000ta

1 Answer

Kipor ig6000 overload alarm


most warning and alarm's are set less than what the manufacture rating is. it's a safety feature without it we would overload all our stuff

Sep 23, 2012 | Kipor Electrical Supplies

1 Answer

Problem with a kipor 12 ta generator


Hi,
I just guessing here but it could mean that the oil pressure is too low.
I'd check the oil level first, then look for the oil pressure switch and temporarily disconnect it.

Regards,
Carl

Feb 19, 2009 | Kipor Electrical Supplies

Not finding what you are looking for?
Electrical Supplies Logo

Related Topics:

550 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kipor Electrical Supplies Experts

jhnolson

Level 3 Expert

822 Answers

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

joe_jochoa

Level 1 Expert

22 Answers

Are you a Kipor Electrical Supply Expert? Answer questions, earn points and help others