If its gas need engine info because it could be a couple of issues

Posted on Dec 30, 2013

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What does "hard start" mean


The compressor is having trouble starting. You can wire in a hard start kit to help the compressor start. Its easy the hard start has two wires one goes to Common on the capcitor and the othe goes to the HERM terminal on the capacitor.

Jul 19, 2011 | Heating & Cooling

2 Answers

My ac central air is blowing air but not cold


Problem #1:Outdoor condensing fan motor has stopped running. This problem could be caused by a bad motor run capacitor. If your motor capacitor is not the problem, then more than likely you need a new motor. Is the fan blade tight, stiff or hard to turn? If the fan blade is hard to turn then you probably need a new motor. Problem #2: Air conditioner compressor will not start. When power is applied to the air conditioning outdoor unit the fan starts, but you hear a sound like the compressor is trying to start, "UGGG"..., for about 5 to 10 seconds and then all you hear is the outdoor condenser fan run. The compressor is locked and will not start. What is happening is the compressor is trying to start, but because the compressor motor is locked it tries to start for a few seconds and then because of the high amperage being drawn goes off on internal overload. The internal overload protects the compressor windings from overheating and burning up. I see this many times during the start of the air conditioning season. Some compressors just have a hard time starting after sitting all winter long. Some compressors are locked up so bad that I can not start them and must tell my customer that they need a new compressor . Many times I can get the compressor started again without having to buy a new compressor or new air conditioning system by using the device known as a "Super-Boost." I keep two or three of these on the truck. They have saved many of my customers from having to buy new air conditioning compressor. Another good device is called a "5-2-1" kit.

Jun 22, 2011 | Goodman CKL36AR36 Air Conditioner

1 Answer

Running but no cool air blowing


Problem #1:Outdoor condensing fan motor has stopped running. This problem could be caused by a bad motor run capacitor. If your motor capacitor is not the problem, then more than likely you need a new motor. Is the fan blade tight, stiff or hard to turn? If the fan blade is hard to turn then you probably need a new motor. Problem #2: Air conditioner compressor will not start. When power is applied to the air conditioning outdoor unit the fan starts, but you hear a sound like the compressor is trying to start, "UGGG"..., for about 5 to 10 seconds and then all you hear is the outdoor condenser fan run. The compressor is locked and will not start. What is happening is the compressor is trying to start, but because the compressor motor is locked it tries to start for a few seconds and then because of the high amperage being drawn goes off on internal overload. The internal overload protects the compressor windings from overheating and burning up. I see this many times during the start of the air conditioning season. Some compressors just have a hard time starting after sitting all winter long. Some compressors are locked up so bad that I can not start them and must tell my customer that they need a new compressor . Many times I can get the compressor started again without having to buy a new compressor or new air conditioning system by using the device that is called, "Super-Boost." I keep two or three of these on the truck. They have saved many of my customers from having to buy new air conditioning systems

Jun 15, 2011 | Weather King 10AJA3601AH Air Conditioner

1 Answer

We have Goodman AC unit...not sure what kind. It has blown VERY cold until the last few days where it would stay a little above where I had it set. Then yesterday I realized it was incredibly hot. My...


Problem #1:Outdoor condensing fan motor has stopped running. This problem could be caused by a bad motor run capacitor.
If your motor capacitor is not the problem, then more than likely you need a new motor. Is the fan blade tight, stiff or hard to turn? If the fan blade is hard to turn then you probably need a new motor. Problem #2: Air conditioner compressor will not start. When power is applied to the air conditioning outdoor unit the fan starts, but you hear a sound like the compressor is trying to start, "UGGG"..., for about 5 to 10 seconds and then all you hear is the outdoor condenser fan run. The compressor is locked and will not start. What is happening is the compressor is trying to start, but because the compressor motor is locked it tries to start for a few seconds and then because of the high amperage being drawn goes off on internal overload. The internal overload protects the compressor windings from overheating and burning up. I see this many times during the start of the air conditioning season. Some compressors just have a hard time starting after sitting all winter long. Some compressors are locked up so bad that I can not start them and must tell my customer that they need a new compressor . Many times I can get the compressor started again without having to buy a new compressor or new air conditioning system by using the device called, "Super-Boost." I keep two or three of these on the truck. They have saved many of my customers from having to buy new air conditioning systems.

Jun 11, 2011 | Heating & Cooling

2 Answers

The fan on my outside heat pump is running slow and the compressor attempts to start but quickly stops and trips the braker.i was told that could be the capacitor. could it be?


depending on the outside temp compressor may have a hard time starting in cooler weather. I would us a hard star capacitior connected to your existing capacitior and this should take care of the hard starting problem.

Dec 09, 2009 | Goodman CLQ36AR49 Air Conditioner

1 Answer

Wont start and pulls hard some of the time


Drain the air tank completely Thats what I have to do to mine otherwise you're fighting the air pressure Think they'd tell you in the instructions

Oct 22, 2009 | Air Tools & Compressors

2 Answers

The a/c keeps cutting off before the room gets cold. The fan stays on but now cold air.


check the timer settings on the control. they may be set to something you may not wish to be set..

Aug 29, 2009 | Heating & Cooling

1 Answer

When tank is low on pressure, the motor cuts in but compressor struggles to turn and trips.


some compressors require an air release that drains the pump head when the compressor reaches full pressure if this is not working the compressor tries to start with full pressure on the pistons which is hard on the motor. If you always heard a small release of air when the compressor shut off yours probably had this feature. drain all the air out and if it starts fine that may be where the problem is. If its one of the smaller oiless ones the motor start capacitor is probably bad

Jul 10, 2009 | Psi Air Tools & Compressors

1 Answer

Compressor starts hard


Sounds like a voltage drop issue, Use a heavier gauge cord, or a shorter one , closer to the source.

May 18, 2009 | Makita MAC5200 Electric Powered Air...

Not finding what you are looking for?
Air Tools & Compressors Logo

Related Topics:

23 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hitachi Air Tools & Compressors Experts

John Trevino

Level 3 Expert

1388 Answers

Jim Thurston

Level 3 Expert

670 Answers

Doctor PC
Doctor PC

Level 3 Expert

7733 Answers

Are you a Hitachi Air Tool and Compressor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...