Sound proublem in TV (Thomson make)

During watching the TV, sound of TV goes off, after some time sound is recover it self for a short time. but when blowing the fan air on surface of TV then sound goes OK.

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer
Re: sound proublem in TV (Thomson make) - Standard (CRT) Televisions

What to do

Posted on Dec 29, 2013

  • Level 2:

    An expert who has achieved level 2 by getting 100 points


    An expert that got 10 achievements.


    An expert that got 5 achievements.


    An expert who has answered 500 questions.

  • Expert
  • 556 Answers
Re: sound proublem in TV (Thomson make)

1 it might be due to spraker wire loose or its connector loose. 2 loose contact in sound section. 3 some cap faulty. 4 sound ic might be grtting more supply so ic is getting over heated. 5 sound ic might be defective.

Posted on Oct 06, 2007

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

Thomson striker tv

You can select a remote control for this TV. Check the sites linked here. Setup code list, and setup procedure to many popular brand remote controls are given. Selecting the view option, either to Mosaic / Time slide, can be selected by the drop-down list, at the top left of the display window, will make surf easy.

Oct 19, 2013 | Standard (CRT) Televisions

1 Answer

Picture on screen disappears and horizontal light appears in the middle of the screen

you need to replace the vertical transistor of your tv. be careful if you want to try to fix it your self. there's high voltage inside the tv.... u need to call the technicians. the transistor won't cost you too much. it's pretty cheap. safety first. good luck

Jun 14, 2012 | Thomson Standard (CRT) Televisions

1 Answer

I was watching the news and it shut off on its own and will not turn back on. What do i need to check?

If you include how many times the standby light flashes, that will give a fault location. Not to worry, here is a list.
Hope this helps.
  • Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).

  • Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.

  • One blink - not used for the self-diagnosis

  • Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.

  • Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.

  • Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505

  • Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.

  • Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.

  • Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.
  • Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.
  • Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).
  • Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.

Jan 23, 2011 | Sony FD Trinitron WEGA KV-27HS420 27" TV

1 Answer

28VK25US Thomson tv, install menu comes up each time switched on.

My Thompson TV only works on av3 thus I cannot get discs to
accept as this has to be on av1 how do I tune in?

Jan 28, 2010 | Thomson 28VK25US TV

1 Answer

How do I retune my Thomson Digital TV 24WK25UG after digital switchover in Granada area

this tv is not a dtv tv you can only watch digital tv if you now have a freeview box this is conected via a scart lead . you select av on the tv remote . or you can watch sky or cable . these are connected the same way .

Dec 04, 2009 | Thomson 24WK25U 24" TV

1 Answer

Lost sound on my GE (Thomson)46GW947X1

pls. first open your tv menu and select sound & colour -sys see the sound-sys / colour-sys is maching with your country transmitiongh sys {EXP.: PAL-BG / NTSC-DK /NTSC- MN /SCEAM- I ) IF your not set purfictly pls select AUTO colour sys and set automaticly set colour & sound .[see user's menual book and set your tv.]

Oct 06, 2009 | GE 35GT695 TV

1 Answer

Thomson TG585 v7 malfunction

just one answer frimware filure did you skip or try to frimware you self with lan cable

Jan 17, 2009 | Thomson 29DM400 29" TV

1 Answer

We have thomson tv 32" color crt sort length model 29df45 c s /icc20

tv power goes off when vcd / dish receiver is connected

Aug 12, 2008 | Thomson 29DM400 29" TV

1 Answer

Rca direct view tv 36" f36665

clicking,w/no sound or pix is usually IHVT, AKA flyback transformer.Please clarify size and model #. Include last three characters in Thomson products service #---Ex.=F36665-YX01.

Oct 02, 2007 | RCA 32F531T 32" TV

1 Answer

Tv shuts off while watching

replace EHT (extra high tension) transformer

Feb 07, 2007 | Philips TS3661C 36" TV

Not finding what you are looking for?
Standard (CRT) Televisions Logo

Related Topics:

355 people viewed this question

Ask a Question

Usually answered in minutes!

Top Standard (CRT) Televisions Experts

The Knight
The Knight

Level 3 Expert

66352 Answers

matt martin
matt martin

Level 3 Expert

1187 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Are you a Standard (CRT) Television Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides