Question about GE Spacemaker JVM1640SJ Microwave Oven

1 Answer

GE Advantium 120 control panel and displays seem to work. Stove top lamp, exhaust fan work. When I press start, there is a click, the interior lamp comes on, but no microwaves and no turntable.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 178 Answers

This sounds like a bad secondary interlock switch. The timer counts down but no cook??

Posted on Nov 20, 2013

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 4 Answers

SOURCE: ge advantium 120 microwave

It's pretty simple as long as you have an offset phillips screwdriver...

Of course, be sure to disconnect power to microwave and be sure not to touch the new halogen bulb with fingers.

STEP-BY-STEP:
First, remove upper vent panel and remove inner filter (same directions for just replacing inner carbon filter):
5c3b6e2.jpg 38afa6d.jpg af02b4c.jpg

Then, remove inner plastic grille (2 screws) and final screw on left side of metal "air duct" - here's where you'll need the offset screw driver (and a little patience!):
6229660.jpg 7165bd6.jpg d09f0af.jpg

Then, you can gently lift the sheet metal panel, find the light housing, squeeze and remove/replace :)
64ca8cc.jpg fb5e58a.jpg


That's it...just replace bulb and reverse for reassembly. Be sure to keep track of screw locations there are various sizes/lengths used.

Doug

Posted on Dec 26, 2007

MicrowaveSvc
  • 9047 Answers

SOURCE: GE Microwave Keypad or Control Panel

If some pads on the keypad are not working, then you have a failed keypad.

If you (or someone you know) might want to replace it yourself, I have uploaded a handy guide with pictures showing you what's typically involved.

You can usually find helpful exploded view diagrams and order parts by entering your full model number here.

There should also be a "mini-manual" hidden inside the unit behind the control panel or hidden on the left side behind the grille, which is very helpful when troubleshooting & testing.

If you would like to have us do this for you, we do that for $39.95 plus part costs.

On this model, the cover will have to come off to replace the light bulb. If it's mounted in the wall, it will have to come down.

The installation instructions are nice to have in this case. You can download GE owner's manuals and installation instructions here.

I have attached a drawing to show where the bulb is on this model. It is located on the right side of the oven next to the wall of the cooking cavity.

The bulbs are available in local grocery stores, hardware stores, and stores like Wal-Mart and Lowe's.

Please feel free to contact me directly if you need more help.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
prototech@usa.net
http://www.microwavedisplay.com

b4f2c5a.jpg

Posted on Sep 27, 2008

MicrowaveSvc
  • 9047 Answers

SOURCE: GE Advantium 120 Microwave fan stays on, off only when door open

Looking at the schematic in the service manual here, I would say relay RY6 on the small sub PCB (relay board) has shorted contacts.

That's the relay that runs both the fan and turntable.

It's possible that it may be a bad connection or driving component on that board, but in my experience, it's virtually always a stuck relay.

The part number on the relay as shown in the photo is hard to read, but it looks like "OJ-SH-112LM".

I should have one of these or I can point you to one if you want to contact me with the exact number.

Feel free to contact me directly (and please remind me of your full model number) for more information & help.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
prototech@usa.net
http://www.microwavedisplay.com

7e1615b.jpg

Posted on Jan 31, 2009

  • 1 Answer

SOURCE: control panel "locked" on ge advantium 120

You might have set the child lock. Look in the manual. It is on P.36 in my manual.

Posted on May 16, 2009

MicrowaveSvc
  • 9047 Answers

SOURCE: Kenmore Elite Advantium 120, model # 363.63693301,

You probably just have a bad primary interlock (upper door switch) or its mount is loose or broken.

Door switch or mount trouble is usually caused by slamming the door or by opening the door while it's cooking without hitting the Stop pad first.

There are plastic mounts inside the microwave which hold the door switches and onto which the door latches lock when you close the door.

The screws on these mounts may be loose. If they get too loose, the switches will not be activated properly.

Sometimes it's a broken tab on the switch holder, allowing the switch to rotate just out of position. This tab can be hard to see, since it is under the bottom edge of the switch.

If the switch mount is broken, it's usually more economical and safer to add a dab or two of hot glue to the mount to secure the switch. Let it cool for about 30 minutes before using.

We have the service / repair manual for this model and have uploaded it to our site here to help you.

It will give you safety info, step by step help in disassembly, troubleshooting tips, and part numbers.

Most computers will open this document automatically, but you may need the free Adobe Reader.

For more on door switches & mounts, see:
http://www.microwavedisplay.com/doorsw.txt

You can find helpful exploded view diagrams and order parts by entering your full model number from the tag on the oven here.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

But if you need any cosmetic parts,
enter your full model number at the Sears parts site.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Posted on Jul 13, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How to change nightlight bulb on ge advantium 120 oven


Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

Aug 25, 2012 | GE Microwave Ovens

2 Answers

Interior bulb needs to be replaced. What needs to be removed to gain access? Thanks


Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.
Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.
Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.
Check here

http://www.geappliances.com/search/fast/infobase/10000007.htm

Advantium - Interior Light Operation While Microwaving

The Advantium 240 oven interior (cavity) light will illuminate anytime the door is open. However, due to the dark tint on the oven door, there is not a light on while cooking since the food would not be visible using the interior lamp.
Food may be viewed during a microwave cycle by pressing the Microwave/Oven Light pad.

One of the Upper Level Speedcook lamps will come on for 5 seconds. The Microwave/Oven Light pad can be pressed up to 5 times during a microwave cooking cycle. The limit of 5 times is to prevent excessive heat on microwave cookware from the Speedcook lamp.

The Advantium 120 oven cavity is illuminated anytime the door is opened and while the unit is in the microwave only mode. As a result it will not have the Microwave/Oven Light pad.

If the light is not operating properly, you will want to have it checked by an authorized service technician. To obtain in or out of warranty repair on Major Appliances, you may call 1-800-GE-CARES (800-432-2737) or schedule service online.

Aug 25, 2010 | GE Advantium 120 Convection/Microwave Oven

1 Answer

Microwave doesn't work


Sounds like you have a faulty control panel. I would use a meter and test the power from the control board to the magnetron and circuit board. Chances are the control panel is faulty

Jul 25, 2010 | GE Microwave Ovens

1 Answer

How do I unlock the control panel


If this is a GE Advantium series microwave, the control panel can be locked to prevent children from manipulating the controls. To lock or unlock, press and hold the CLEAR/OFF button for 5 seconds. These instructions are included on page 36 of the owner's manual listed here:


http://www.managemylife.com/mmh/owner_manuals/14895/GE-Built-In-Microwave-Oven-L0902200?brand_name_search=+GE+Advantium+120


If you have questions, please post back and let me know. Please include your MODEL NUMBER if diffrent form the model you posted this question under. I hope this helps you.

May 20, 2010 | GE Advantium 120 Convection/Microwave Oven

2 Answers

GE Advantium 120 oven: Was boiling water and oven completely powered off. House circuit breaker is OK and not tripped. Plugged into another working outlet with extension cord to see if display came on. It...


You will need to remove the top grill vent first, then you can remove the screws coming in from the top of the grille vent then that will expose a screw holding down the control panel at the top. Remove the screw and remove the control panel. The fuse is located in a little 1" fuse holder just behind the front panel near the top.

Feb 05, 2010 | GE Advantium 120 Convection/Microwave Oven

1 Answer

Control panel "locked" on ge advantium 120


You might have set the child lock. Look in the manual. It is on P.36 in my manual.

Apr 30, 2009 | GE Advantium 120 Convection/Microwave Oven

1 Answer

Power level


Hi cindeet,

I don't have this particular model, but have experience with other GE stoves & ovens. Looking at the control panel for an Advantium 120 at the link below,

http://www.geappliances.com/products/introductions/advantium/downloads/advantium_brochure.pdf

I'd start by pressing the "Power/Temp" button, and then turn the knob to select which power level.

There is also a Help menu shown (upper left corner of the photo I'm looking at - page 4 of the PDF document referenced above.

Let me know how this works for you - thanks in-advance.

Jon

Dec 23, 2008 | GE Advantium 120 Convection/Microwave Oven

1 Answer

How do I replce the small bulb thats under the microwave and


Any Ace Hardware store will have it...
GE Edison Halogen 20 12 volt replacement lamp...

Nov 11, 2008 | GE Advantium 120 Convection/Microwave Oven

1 Answer

GE Advantium SCA 1001HS


Should be able to get to the lamp by removing the grill.

Oct 04, 2007 | GE Advantium SCA1000H Convection /...

2 Answers

GE Profile Advantium Wall Oven 240 volts 950 Watts


How long does it run before it fails? Does it look like the display is getting scrambled characters? I'm leaning toward a bad magnetron, but it may be more or less than that. If you can give more details and especially the actual full model number (as opposed to the model name Advantium 120) that would help. Thanks!

Oct 02, 2007 | GE Advantium 120 Convection/Microwave Oven

Not finding what you are looking for?
GE Spacemaker JVM1640SJ Microwave Oven Logo

74 people viewed this question

Ask a Question

Usually answered in minutes!

Top GE Microwave Ovens Experts

D. E. Hev

Level 3 Expert

1167 Answers

 Larry
Larry

Level 2 Expert

115 Answers

Shekar Avadhani

Level 2 Expert

61 Answers

Are you a GE Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...