Question about Water Heaters

Open Question

Amtrol boilermate wh7p E2 code - Water Heaters

Posted by Anonymous on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 1 Answer

SOURCE: No hot water from the Amtrol Boiler Mate model

The smart control was only reading 140 it never went up or down from that number and now it has an ER3 code seem the circulator just runs and runs

Posted on Feb 14, 2010

  • 10865 Answers

SOURCE: no hot water have amtrol boilermate

There is a device on the boilermate called an aquastat which controls the flow of hot water into it. Replace that and you should be up and running again. Joe.

Posted on May 23, 2010

aquaman987
  • 927 Answers

SOURCE: wondering how much this 2007 boilermate wh7p

Therm X Trol Amtrol ST-12 Water Heater Expansion Tank - eBay (item 390194010683 end time Jan-05-11 07:59:01 PST)

This is on E-Bay for $58, new from a supply house.

Let me know if this helps.
Gary

Posted on Dec 18, 2010

  • 1 Answer

SOURCE: ER3 no hot water

Er3 means that the water is being heated for more than 1 hour without reaching the set temperature.
Need new aquastat.

Posted on Dec 28, 2010

packrat1948
  • 528 Answers

SOURCE: if the amtrol boilermate water




If the area it is in is heated it will not freeze any more then the water piping would.

Posted on Feb 02, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

AMTROL WH7P-41 GAL TANK. 12 YRS OLD. BOILER PRESSURE IS INCREASING ABOVE 30PSI, AND DUMPING SMALL AMOUTS OF WATER FROM RELIEF VALVE ON BOILER. Do I replace coil?, or buy a new tank? Thank you


do you have a pressure tank as part of your water heater and water pipes? if yes, check to make sure tank pressure matches your incoming water pressure from your municipal hook up

Aug 18, 2015 | Amtrol Water Heaters

3 Answers

Boilermate er3


is it an electric or gas or oil fired. Er3 means it is not getting up to temperature within the required time. Electrical - element bad. for oil or gas, no ignition or fuel supply.

Oct 28, 2013 | Amtrol ST-120V-C THERM-X-TROL ASME...

1 Answer

Boilermate wh-7l, thermostat


Your BoilerMate obtains its energy from the home's boiler and does not have a reset button itself. I work for Amtrol, the manufacturer, and can be of assistance with more info. What is the problem you are experiencing?

May 28, 2012 | Water Heaters

1 Answer

No hot water have amtrol boilermate. boiler works fine to heat house just not hot water


There is a device on the boilermate called an aquastat which controls the flow of hot water into it. Replace that and you should be up and running again. Joe.

May 23, 2010 | Water Heaters

1 Answer

Amtrol wh7p


https://youtu.be/pUOBR1k3KvM- try seeing if this video answers anything. If not, there are a bunch of others about water heaters; just look around until you find one that looks similar to the one you have and watch. Sometimes, you get lucky lol

Jun 14, 2017 | Amtrol ST-12-C THERM-X-TROL ASME Expansion...

1 Answer

Beeping noise


E2 means hot water over shot, make sure to check boiler hot water system to make sure zone valve or control is staying closed when the call for boiler hot water to the water heater is isolated. Sometimes a zone valve will fail open or not close properly causing hot boiler water to constantly feed the water heater.

Dec 08, 2009 | Amtrol Water Heaters

1 Answer

ER3 no hot water


Er3 means that the water is being heated for more than 1 hour without reaching the set temperature.
Need new aquastat.

Sep 28, 2009 | Amtrol ST-120V-C THERM-X-TROL ASME...

2 Answers

Amtrol Boilermate makes whining noise


I had also this problem before, same with buzzing sounds on my Amtrol Boilermate and all I had to do was to call the local dealer and they have got it fixed.

May 05, 2009 | Emerson Part UWL Chrome Ultrasystem water...

2 Answers

No hot water from the Amtrol Boiler Mate model wh7p


The smart control was only reading 140 it never went up or down from that number and now it has an ER3 code seem the circulator just runs and runs

Mar 09, 2009 | Water Heaters

Not finding what you are looking for?
Water Heaters Logo

Related Topics:

39 people viewed this question

Ask a Question

Usually answered in minutes!

Top Water Heaters Experts

Donni Steen

Level 3 Expert

659 Answers

Brad Brown

Level 3 Expert

15441 Answers

Gil Shultz

Level 3 Expert

3368 Answers

Are you a Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...