Question about Quantum 6000 Power Chair - Used Electric Wheelchairs

1 Answer

My quantum 6000 yellow light on joystick monitor reads left motor disconnected

Posted by on

1 Answer

Check wires

Posted on Oct 19, 2013

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

When I go To move the chair comes up with error 107. , charger inhibit . I disconnected the charger. What can I do next


after do a test restart the chair. make sure both freewheel levers are locked in drive mode (hard to push), restart, make sure your connections are good, to the motors and brakes. what kind of Joystick is this?

Apr 07, 2016 | Quantum 6000 Power Chair - Used Electric...

1 Answer

My quantum 600 wheel chair won't work it says system lock


My quantum 600 wheel chair won't work it says system lock ...

www.fixya.com/.../t26033304-quantum_600_wheel_chair_work_says_s...
2 hours ago - My quantum 600 wheel chair won't work it says system lock -Wheelchairs question.

Pride Mobility Quantum Q6 Edge (Power Wheelchairs ...

www.usatechguide.org/itemreview.php?itemid=1626
Quantum 6000 or 600 Rehab Power Wheelchair - CareCure Communitysci.rutgers.edu/.../showthread.php?...Quantum-6000...Rutgers UniversityJul 4, 2008 - 10 posts - ‎9 authorsI had the QUANTUM 600e Rehab Power Wheelchair for six months. ... C-500 Hvy dutypower chair w/hi-speed motors, power seating system, .... I have a Q600 with tilt, recline, leg extension, Q-logic..pretty much the works. ... the thing shuts itself off andwon't move when I have anything under 90% charge?Quantum® 600 Power Chair Reviews - Pride Mobilityownersclub.pridemobility.com/reviews/item/1/20The Quantum® 600 Power Chair delivers the stability of patented Mid-Wheel 6® ... At that same time the 3rd motor set was changed my seating system was ... We were rescued by boat and my friends say the wheelchair was working ... Insurance won'tcover a power chair for me yet so I had to pay out of pocket for this one.

Jan 01, 2016 | Health & Beauty

1 Answer

Push power button wont go but all the adjustments legs back tilt works


quantum 600 wheelchair troubleshooting Questions ... - Fixya

www.fixya.com > Forum > Tags
quantum 600 wheelchair troubleshooting chair won't go all i get form joystick is a picture of a ... around in a square there should be a rest button on the rear of the chair ,push ... Question about 600 E Electric Wheelchair - Used Power Chair.

[PDF]Pride Quantum 600 Owners's Manual - Scootaround

www.scootaround.com/.../Pride%20Quantum%20600%20Owner's%20M...
Quantum 600 .... The symbols below are used on the power chair to identify warnings, mandatory actions ... Pride will not be held responsible for injuries and/or property ...complete stop by releasing the joystick, then push the joystick forward slightly to .....breaker button, turn on the controller, and continue normal operation.

[PDF]Quantum 600E Owners Manual - Scootaround

www.scootaround.com/.../Pride%20Quantum%20600E%20Owner's%20...
Quantum 600E .... The symbols below are used on the power chair to identify warnings, mandatory ... chair. Pride will not be held responsible for injuries and/or property ... complete stop by releasing the joystick, then push the joystick forward slightly to ..... breaker button, turn on the controller, and continue normal operation.

[PDF]Quantum 600 Series - Pride Mobility Products


Dec 30, 2015 | Quantum 600 E Electric Wheelchair - Used...

1 Answer

Nutron r51


The age of the Nutron is not the issue, unfortunately. I have seen problems with this model right out of the box. The joystick control is the first area to check. If you have to compensate the joystick so far to the right to correct, you may have a damaged joystick gimbal. You may also have a bad joystick control board or damaged connecting cable to the controller on the bottom frame. Check for damaged, pinched loose or disconnected wiring below at the controller module. With a folding frame it is easy for the wiring to be become damaged or dislodged. Check for cut damaged pinched wiring at the joystick. With a handheld programmer (dealer) you can check for error codes in the fault log. With a poor performance issue there may not be a fault recorded in the log of the computer module. I have also seen these motors fail prematurely. In this case your left motor is dragging or weak causing the chair to go left. With a programmer (dealer tool) you can compensate for this while waiting for new parts(temp fix). Sometimes the motor brushes burn or hang up. Try blocking up the chair off the ground and run it no load to check for motor performance and unusual sounds. Check for joystick dead spots or uneven action. A quick check of the joystick would be to plug in a known good one at the dealer to test. With the chair blocked up try tapping the motor housing to see if the performance changes. Inspect the brushes if you have access to the brush caps.Check the obvious first, plugs, pinched, broken wires and partial plug disconnects and corrosion. If you have a voltmeter you can do some checks on the motors and brakes. Going from memory, the motor leads large black and large red should read zero ohms with the 2 small white wires for the brake reading between 60 and 70 ohms. Check the Invacare manufacturer website for exact specs and technical info for this model.
Hope this helps.

Mar 22, 2014 | Invacare Supply Group Nutron R51 LXP...

1 Answer

Blinking yellow wrench light on pride jazzy 614 HD


Your version has a Dynamic Controls model controller and joystick.
Unplug the charger and engage the motor/brake lever so the chair is no longer in free-wheel mode (con't push by hand)
Turn the chair off, wait 5 seconds, turn the chair back.
If chair still does not run and your wrench is flashing you have a problem. Count the wrench flashes - the flash count indicates the error detected. 3, 4, 5, and 6 flashes indicate and error with the motors.
3=Left motor fault
4=Right motor fault
5=Left brake fault (may not be engaged)
6=Right brake fault (may not be engaged)
Any other fault code usually means the electronics or wiring is bad and not worth fixing.

Jan 06, 2013 | Pride Jazzy 614 Hd JAZZY 614HD

2 Answers

Invacare MKIV R11 Flashing lights


One of the most common controllers, codes to help you and others.

powerc24.jpgpowerc25.jpg



VSI & VR2 Joystick error flash codes:
1 RED BAR:
Low Battery Voltage The battery is flat (more likely).
Or the battery has a bad connection (which is unlikely)
2 RED BARS: Left Motor Disconnected The left motor is disconnected. Check all the connections for physical disconnection or corrosion or burning usually caused by the salt poured onto the roads every winter.
3 RED BARS: Left Motor Wiring Trip The left motors wiring has a short circuit. Check all connections and leads for wear and chafing between the left motor and the battery cables or chassis
4 BARS: Right Motor Disconnected The right motor is disconnected. Check all the connections for physical disconnection or corrosion or burning usually caused by the salt poured onto the roads every winter.
5 BARS: Right Motor Wiring Trip The right motors wiring has a short circuit. Check all connections and leads for wear and chafing between the right motor and the battery cables or chassis
6 BARS: Activated if you turn on your wheelchair with an external device like the Charger still connected.
7 BARS: Possible Joystick Trip, Make sure that the joystick is in the centre position before switching on. If you still get this when switching on then joystick is probably faulty.
8 BARS: A control system trip. Make sure that all connections are secure and if so the power module or control pod is probably faulty. Test by substitution of known good one.
9 BARS: The parking brakes have a bad connection or have a failed solenoid, or any lever or switches that disconnect drive for pushing the chair manually may be pulled or switched.
10 BARS: Over voltage detected. This can happen with a bad battery connection although unlikely. More likely your battery charger is faulty and is overcharging your batteries quite severely.
1 BAR to 10 BARS and back in a "ripple" every few seconds. Joystick not cantered when turned on. Switch off and try again.
1 BAR to 6 FLASH every few seconds. System Asleep. Switch off and back on. Time before sleep can be adjusted or disabled in programming


Hope this helps, If so please click the "Yes" button

Regards, Mark.

Jul 12, 2012 | Invacare Pronto M51 Power Wheelchair

2 Answers

Our Jazzy Select G.T. power wheel chair won't run. The lights keep blinking when the power is turned on but won't run..? Why? Battery is charged.


Hi
delobner,

Sometime we lock our vsi joystick by mistake. Here are the instructions on how to lock and unlock your joystick.

If the problem is still there after write me back and I'll help you.

LOCKING/UNLOCKING THE VSI

The VSI has a feature that enables you to lock your power chair to prevent

unauthorized use.

To lock the VSI:

1. With the VSI powered on, press and hold the on/off key. After one (1)

second, the VSI should beep.

2. Release the on/off key.

3. Push the joystick to the full forward position until the VSI beeps.

4. Pull the joystick to the full rearward position until the VSI beeps.

5. Release the joystick. There should be a long beep.

6. The VSI is now locked.

To unlock the VSI:

1. Press the on/off key and power on the VSI. The maximum speed/profile
indicator should ripple side to side.

Good Luck
mi mobility

Feb 18, 2011 | Pride Jazzy Select 6 Indoor Power...

1 Answer

I just replaced the batteries in my Jazzy 1170 PLUS. Now my speed control lights blink constantly and the chair is totally unresponsive.I have double checked to be sure the freewheel levers are totally...


According to my 1170 manual the flashing lights are error codes. 1 red = low batt., 2 red = left motor disconnected, 3 red = Left motor wiring fault, 4 yellow = Right motor disconnected, 5 yellow = right motor wiring fault, 6 yellow = Inhibit active, 7 yellow =possible joystick fault, 8 green = possible controller fault, 9 green = Solenoid brake fault, 10 green = high batt. voltage

Feb 13, 2011 | Pride Mobility Products Jazzy 1170 XL Plus

1 Answer

What can be used to clean the contacts on the Shark power module for our CTM HS 2800 power wheelchair? There are 2 red, 2 yellow & 2 green lights on this chair that flash once and go off and then come...


This power wheelchair uses a Shark joystick control made by Dynamic. The connecting cable plugs into the back of the joystick control and can be unplugged by pulling back on the lock ring of the connector. Spray electrical contact cleaner onto both the plug and the joystick cable receptacle.
Follow the cable down to the base and check for cuts, nick or pinches and repeat at the base connector. To get to the power module you need to remove the seat and cover for the base. The controller should have 5 connectors plugged into it. One is the power connector, one is the right motor, one is the left motor, one for the joystick plug, one for the charger. Remove these connectors one at a time, spray clean the contacts and plug back in. Inspect these connections on both sides and be certain the contacts are shiny.
A 6 bar flash indicates that there is a right park brake fault. Work the right brake release lever up and down several times and see if this clears the fault. Do the same for the left brake. If you have cleaned the right motor plug at the controller by disconnecting it you can use a digital voltmeter to test the brake. The 2 small wires to the plug are the brake wires and should read 40 to 60 ohms on your meter. If the brake solenoid reads open or shorted your brake is burnt out. The two easiest things to try are moving the brake levers and spray clean all the contacts. The test/replacement of these parts requires a qualified technician. Hope this helps.

Nov 22, 2010 | Ctm HS-2800 Power Wheelchair

Not finding what you are looking for?
Quantum 6000 Power Chair - Used Electric Wheelchairs Logo

129 people viewed this question

Ask a Question

Usually answered in minutes!

Top Quantum Health & Beauty Experts

Scooter Doctor
Scooter Doctor

Level 3 Expert

351 Answers

jeff tilburn
jeff tilburn

Level 3 Expert

867 Answers

wcdoc1953
wcdoc1953

Level 2 Expert

278 Answers

Are you a Quantum Health and Beauty Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...