Toshiba E-Studio 225 Copier Logo

Related Topics:

A
Anonymous Posted on Oct 17, 2013

C44 error code - Toshiba E-Studio 225 Copier

1 Related Answer

didi2005

  • 727 Answers
  • Posted on Mar 09, 2009

SOURCE: toshiba 160 error code

For error code C44, it indicates Heater abnormality.

If 1st time occur, u can just go to 08-400, reset the value to "0" then restart the machine.

If happen again, then u need to check the thermistor. Replace it if necessary. If themistor replaced but still happen again, then u need to proceed to check themostat--> heater-->Mainboard-->Switching regulator.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Reset spanner error

There are several error you need to know the sub code by pressing c and 8, frequently you may come across the error code C44,C97,C26
.For C44 the error clearance is "switch on the copier while pressing 0&8 AD will appear enter 400 and press start (print) button and enter "0" and press Interrupt button , switch off and on the machine .If the error code is C97 the main charger to be cleaned in drum unit, If it is C26 you need to check the scanner cable..Hope the anser.
0helpful
1answer

E studio 520 code c447

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0." also 447
0helpful
1answer

Error code c43

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
2helpful
1answer

Call for service C 430

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
1helpful
1answer

Error c44 studio

codes c43, c44, c45
problem with the fuser
thermistor review
thermal fuse
check connectors
3helpful
1answer

Toshiba estudio 181 gives error code c44 any button not working

C44 indicates fuser problem.
Try perform 08-400, set to "0" to reset the error.
If persist, u need to check the themistor & heater lamp on the fuser unit.
3helpful
1answer

TOSHIBA E STUDIO 207 ERROR C 44

All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."
10helpful
3answers

I am looking to reset my toshiba studio 163 spanner signal.the machien stoped functioning. i need he reset code.

Hello
Fisrt off please hold down the 8+C buttons together, there will show a error code in the copy quantity display.
Now not knowing what the error code is, i am going to hope that it is C44 that is the most common
error code on the E163 machine. If it is C44 please do the following.
Switch off the machine.
While holding down 0+8 buttons, switch on the machine.
When ad shows on the display, input 400 then press the start button.
If the value is not 0, input 0 button and press the interupt and energy saver buttons to save the change.
Switch off the machine wait awhile and then switch the machine on again.
The problem should be sorted out.
If the error code is not C44 you will have to let us know what the error code is, by holding the8+0 buttons down together.

Here is hoping the machine is working
Regards
33helpful
6answers

My Toshiba e studio 167 is showing a c44 error code. What should I do?

the c44 error is an error in the fuser if you know how to take the fuser out check for toner buld up on the thermistors.. the sensors with the thin strip that presses against the hot roller gets toner build up and cant read temp properly.. you could also try turning machine off and then on whilst pressing 1 3 and * buttons together this might reset it temporarily for you.. Good Luck A
15helpful
4answers

Toshiba 160 error code

c44 = fuser error
turn copier off
hold down 0 & 8 while turning it on

then wait one min, then press 4 0 0 start

then 0 and set

turn off wait one min then turn on if this does not work it might need parts
Not finding what you are looking for?

39 views

Ask a Question

Usually answered in minutes!

Top Toshiba Office Equipment & Supplies Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a Toshiba Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...