Error 5
Description
The power up test sequence has detected a key in the operated condition. The power up test
sequence is performed every time the unit is turned on (powered up). This test is performed
because a permanently stuck key will inhibit the correct operation of the unit.
Possible Causes
1. A key on the display housing is permanently stuck in the operated condition.
2. One of the upper PCA's keypad interface chips has failed.
3. Liquid (perhaps perspiration) is present on the surface of a touch sensitive display.
Possible Remedies
1. Remove the keypad connector cable from the upper PCA. Restart the power up sequence, if
the ERROR 5 is no longer present, the keypad is the cause. The keypad is typically part of
the display housing. Replace the display housing to correct the problem.
2. Remove the keypad connector cable from the upper PCA. Restart the power up sequence, if
the ERROR 5 is still present, the upper PCA is the cause. Replace the upper PCA to correct
this problem. Most upper PCA's are provided without software. Therefore, the software (chip)
must be removed from the upper PCA being replaced and re-installed on the replacement
upper PCA.
3. Wipe the surface of the touch sensitive display clean of all liquid. Restart the power up
sequence, if the

Posted on Oct 14, 2013

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I get a error 05 code on my precor treadmill C932/C964


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Apr 05, 2014 | Precor 932i Treadmill

1 Answer

I get a error 05 code on my precor treadmill C932/C964


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Apr 05, 2014 | Precor 932i Treadmill

1 Answer

Error 5 stuck key


Precor Error 05, Key Depressed at Power Up Probable Cause: 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.

Precor Error Code 05

Feb 17, 2014 | Precor EFX 556 Elliptical

1 Answer

ER 05 displayed on precor 9.31?


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Nov 23, 2013 | Precor Exercise & Fitness

1 Answer

Precor EFX 546 05 stuck key


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Jul 02, 2013 | Precor EFX 546i Elliptical Version 4

1 Answer

Key depressed error


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Nov 13, 2012 | Precor EFX 546i Elliptical Version 4

1 Answer

Error code 05 appeared on screen. We have tried to reset. Hit stop, enter, & quickstart buttons as decscribed. We also tried the reset button. The error code remains. We unplugged and tried again, but...


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Apr 11, 2011 | Precor 933 Premium Series Treadmill

1 Answer

Error code 5


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.

Precor Error Code 05

Aug 11, 2010 | Precor EFX 546i Elliptical Version 4

2 Answers

Iomega HDD Fatal Error 05


Fatal Error 5 is normally indicative of a Disk Failure. Because the OS can't read the portions of the drive.

Jul 05, 2009 | Iomega ScreenPlay

1 Answer

The port the modem is attached to could not be opened; Opening the modem device failed with error 000005aa


Sounds like a hardware problem

First > try changing the modem port (default is com3, try changing it to com4 or com5 whichever is free)

Try querying the modem again

Second > Contact your modem manufacturer

May 26, 2008 | Conexant chipset 56K V.92 PCI Data/Fax...

Not finding what you are looking for?
Bowflex Treadclimber Logo

64 people viewed this question

Ask a Question

Usually answered in minutes!

Top Bowflex Exercise & Fitness Experts

Electro Med Services...
Electro Med Services...

Level 3 Expert

6694 Answers

Shehu Pro
Shehu Pro

Level 3 Expert

1284 Answers

Are you a Bowflex Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...