Question about Heating & Cooling

1 Answer

Inside unit freezing

I have a coleman air unit and the inside is freezing while the outside seems to be fine.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 358 Answers

There are varius items that make the unit inside (air handler) freezes up .If the fan motor in the air handler doesn't work it'llice up.If the filter is dirty it'llfreezes up. If the coil in the air handler is dirty it will freezes up.And if the unit is low in refrigerant(freon) it'll ice up.If is low in gas means there's a leak and before recharged it needs to be fixed.

Posted on Apr 23, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Coleman 2ton Basement air does not respond to thermostat but will turn on and run fine after 6 to 36 hours


Check contactor in condensor,if it looks good check refrigerant levels if you're EPA liscensed.

May 25, 2014 | Coleman Mach III Air Conditioner

1 Answer

Trying to find my model number on my coleman q.e.d II emerson model


try cleaning inside coil. alot of things can make it seem your low on freon. dirty filter, dirty coil, slow fan speed.

Apr 08, 2014 | Coleman Heating & Cooling

1 Answer

Trying to find my model number on my coleman q.e.d II emerson model


Your unit can be low on freezon and can have stop up inside coils if air cant move across coils it will ice up on inside clean coils and check if unit still ice up it low in freezon.

Apr 08, 2014 | Coleman Heating & Cooling

1 Answer

Coleman 8000 compressor only comes on and cools when cool outside like in Am or late pm


Clean the coil inside and outside. try putting it in a window on a shady side of the house. I worked on a outside unit wher it was 90degrees outside but 107 degrees where it was in a hot location, close to road on sunny side of house.

Jul 28, 2012 | Dometic Rooftop RV Air Conditioner

1 Answer

My Coleman Evcon heating and air unit will not blow air


bad blower motor. recommend a new blower motor and capacitor.

May 28, 2010 | Coleman Heating & Cooling

1 Answer

Coleman deluxe blend air ll it starts up


The blowing fan is not rotating at the rated speed. Check the fan capacitor and replace.

Check motor also if the capacitor is not at fault.

May 27, 2010 | Heating & Cooling

1 Answer

Roof air not draining and leaking inside coleman unit


there are 2 drains on most units one each side about 6 inches back from the front of the unit - they are white plastic and have a small hole in the side - they may be clogged - happend to mine - used a paperclip to clear out now work fine - good luck

Aug 17, 2009 | Dometic Rooftop RV Air Conditioner

1 Answer

Unit will not shut off by itself.


A/C only will not shut off would check for low refrigerant charge. If furnace also will not shut off (remember fan will run for short time before shutting down) then either thermostat is wired wrong or control board is defective

Jul 11, 2008 | Heating & Cooling

3 Answers

I have an coleman evcon furnace when i turn a/c on the outside unit will run but the inside wont run


put the just the fan on turn off the ac and the heat and just fan on make sure the blower motor works cause thats really the only thing you utilize from the furnace in the summer and let me know
then if so does your heat work fine

May 30, 2008 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

216 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

2558 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...