Amana sxde25j high voltage board blown..

Hi, i need schematic or just the number on the high voltage board because they completely explode and i cannot read number on Q1 and Q4 ... i replace q1 to q4 with 2n3904 but i still have 1 problem.. q2 come short every time but compressor start ,evaporator fan won't start.. Can you help me to find schematic of this board or number on q1 and q4 please? Thank you

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Brigadier General:

    An expert that has over 10,000 points.

  • Master
  • 3,614 Answers

Hi there,

you can try to this store to order the parts to be replaced part number & description was also indicated in HERE.

just let me know, for further assistance,

Posted on Apr 21, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

SCHEMATIC FOR AMANA DRIER NED7200TW


Hi ,
You cannot jus change the timer.You need to change the user console and display board fully.
Here is the part.Can order online.
http://www.repairclinic.com/PartDetail/User-Control-and-Display-Board/35001269/1185581?modelNumber=NED7200TW10



Here is the parts manual

http://www.searspartsdirect.com/partsdirect/part-model/Amana-Parts/Dryer-Parts/Model-NED7200TW10/1268/0151200


Thank You

Nov 28, 2012 | Dryers

1 Answer

Ald10t fuse keep blowing


If the fuse blows when you open or close the door, then the problem is with the monitor interlock (middle door switch) or its mount.

See my help file on door switches here.

If the fuse blows almost instantly after pressing the "Start" button to begin cooking, then it is a shorted high voltage capacitor.

If it blows a few seconds after pressing "Start", then it may be a bad high voltage transformer.

Here are some links you or someone you know can use for test help, but read their safety warnings first:

http://www.gallawa.com/microtech/xformer.html

http://www.gallawa.com/microtech/cap_test.html

You can find helpful exploded view diagrams and order parts for most Amanas by entering your full model number from the tag on the oven here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Nov 28, 2011 | Amana Microwave Ovens

1 Answer

Replaced the digital main cba now the voltage is too high in the


Have you tried googling the model number, funai is no help if you dont have a contract with them. Finding schematics for their powersupplies is hard, a majority of the time its better to just buy another ps because many of the parts they use wont cross to NTE. Are the voltages coming out of the ps just high? If they are one of the boards might be bad, I had a funai tv that had a bad board and was keeping the rest of the tv from powering up so the volatges I was getting were high due to the lower load. Also check for a schematic for that specific panel as funai uses LG panels in their stuff.

Dec 11, 2008 | Sylvania LC320SS8 32 in. LCD Television

1 Answer

Microwave Not Working


If it went dead almost immediately after pressing the Start pad, that's usually a shorted high-voltage capacitor.

If it went dead a few seconds after pressing the Start pad, that's usually a failing high-voltage transformer.

There should be a "mini-manual" (tech sheet) hidden inside the unit behind the control panel or hidden on the left side behind the grille, which is very helpful when troubleshooting, testing, and locating components.

At our Web site, we have a video available showing how to remove a typical over the range control panel assembly in under 5 minutes.

Here are some links you or someone you know can use (in order given) for test help, but read the safety warnings first:
http://www.gallawa.com/microtech/cap_test.html
http://www.gallawa.com/microtech/xformer.html

You can usually find helpful exploded view diagrams and order parts by entering your full model number here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Nov 27, 2008 | Amana CW65T Microwave Oven

2 Answers

Danby 1000 Watt Microwave is completely dead. Just stopped working right after heating up a dinner.


you may have just blown a fuse inside the microwave or the transformer inside has now failed and will need replacing but it will need to be looked at to see what exactly happened

electech

Nov 27, 2008 | Microwave Ovens

2 Answers

Micro oven went dead while it was heating.


may be high voltage crcuit , magnetron, capacitor , high voltage diodes, control unit.ar mains fuse may be glow out. check the circuit,..

Sep 25, 2007 | Frigidaire PLMV168 Microwave Oven

1 Answer

Not heating


You can find helpful exploded view diagrams and order parts by entering your model number here: http://tinyurl.com/gv383 When a microwave is not heating and is making extra noise, it's usually a bad magnetron or high voltage transformer. But once you've looked over the documentation I pointed you to, let us know if you still have trouble.

Aug 25, 2007 | Amana HDC21 Microwave Oven

2 Answers

Have an AMANA AOGD2750 oven blew electronic board


You will need to replace the ERC module Pn 31799201: expensive $199

May 06, 2007 | Amana AOGD2750 Gas Double Oven

1 Answer

Panasonic CT-27SC14


The high voltage should be around 29.5 KV and not fuctuate between 20-30 KV that would indicate a high voltage regulation issue then. Are the filaments lighted up in the neck of the CRT? If so then yes you are probably looking at a low voltage issue such as a 12 volt source or a a/v switching IC issue.

Apr 23, 2007 | Panasonic CT-27SC14 27" TV

1 Answer

Loud pop


You probably have a blown fuse (15A or 20A ceramic type) which may be caused by a blown part in the high voltage section. These are widely available at local stores. You can find exploded views and parts by entering your full model number here: http://www.geappliances.com/shop/prts/ If the new fuse blows immediately when you hit the START button, you also have a shorted high voltage capacitor. Need more help? http://www.fixya.com/ServiceRvw.aspx?advid=14&ctgid=153

Dec 15, 2006 | Kenmore 63652 Microwave Oven

Not finding what you are looking for?
Amana Easy Reach AFD2535DE Bottom Freezer Refrigerator Logo

162 people viewed this question

Ask a Question

Usually answered in minutes!

Top Amana Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4654 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Sal DeAngelo

Level 3 Expert

2122 Answers

Are you an Amana Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...