Question about Sony Grand WEGA KDF-50WE655 50" Rear Projection HDTV

1 Answer

SONY KDF-50WE655 Cooling Fan

Hi, I'm trying to find the part number for my SONY KDF-50WE655 cooling fan in the back of my set. It's making a whining noise and I need to replace it. Thank you for your help and time, Rob

Posted by on

  • rob302 Sep 20, 2007

    Great info, thank you! I know my faulty fan is one of those, but without schematics, I still need to narrow it down a bit. Can you tell me the name of the fan that is readily visible from behind the set, please? I've traced the sound back to this fan.

    Thank you again,




1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points


    An expert that gotĀ 5 achievements.

    Vice President:

    An expert whose answer gotĀ voted for 100 times.


    An expert who has posted more than 50 answers, of which 90% or more were rated as helpful.

  • Expert
  • 140 Answers

There are three fans: 1)Cooling fan(on the optical block)part# 1-787-057-11 2)Ballast fan part# 1-787-081-11 3)Upper optics fan part# 1-787-460-11 Also make sure you don't have a noisey iris motor in the optical block (verify by adjusting the iris settings in the menu and see if the noise level changes)

Posted on Sep 20, 2007

  • David Makowski
    David Makowski Sep 21, 2007

    That would be fan part# 1-787-057-11.



1 Suggested Answer

  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017


Add Your Answer

Uploading: 0%


Complete. Click "Add" to insert your video. Add



Related Questions:

1 Answer

SONY KDF-50WE655 Cooling Fan has become too noisy. It's not the little horizontal fan that is easy to see but something else near it that keeps whining after the little fan stops.

You have a total of 4 fans in this unit.
Fan# 1 - Optics unit ( left side )
Fan# 2 - Large fan facing rear of set, behind metal shield
Fan# 3 - Optics unit ( right side )
Fan# 4 - Mounted directly above the chassi assy

Jun 19, 2012 | Sony Grand WEGA KDF-50WE655 50" Rear...

2 Answers

Hi I have a Sony Grand WEGA KDF-60XS955 TV

Ur right the cooling fan is defective,check it,clean it might work normal again.Not, than the cooling fan must be change.

May 04, 2010 | Sony Grand WEGA KDF-60XS955 60" Rear...

1 Answer


Dust has accumulated inside the optical assy and cooling fans espesialy on the lamp cooling fan.

Mar 22, 2010 | Sony Grand WEGA KDF-50WE655 50" Rear...

2 Answers

KDF60XBR950 doesnt turn is on just flashes green

There is no less than two Cooling Fans on the right side. Either one of them could cause the problem. The one that turns slow or stops turning quickly is the one that is probably causing the problem.
I hope this helps,
Sky Assoc

Sep 11, 2009 | Sony Grand WEGA KDF-60XBR950 60" Rear...

1 Answer

I have no picture on my sony KDF-50WE655

check the fan again with a flash light. I had this same problem and changed out the large fan behind the more problem. my brother has the same tv and he has had to replace the fan at least three times.

Jun 08, 2009 | Sony Grand WEGA KDF-50WE655 50" Rear...

1 Answer

Is the t603 and r672 part of the tv or the actual circuit breaker

Three blinks - B over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.

DOES THIS ABOVE issue have anything to do with Cooling FAN?
I cannot hear the cooling fan come on when first turned on like
before THANKS

May 05, 2009 | Sony Grand WEGA KDF-50WE655 50" Rear...

2 Answers

If my lamp is out, would sound be present?

Check lamp cooling fan for dust blockage. It is located inside the back cover (10 screws) and is in a horizontal position above the lamp from the rear side. This is an air intake fan. The cooling fan you can see on the back panel is the exhaust fan that sucks out the hot air. A clue is hot or melt marks around the lamp housing.

If the lamp cooling fan is blocked you'll get red flashing diagnostics light flashing. It's trying to say clean me so I can keep the new lamp cool. Sony is silent on this in it's manuals. I'm guessing they don't care because is causes lot's of parts business!

I learned all this after replacement lamp burnt out after 1 week. My lamp cooling intake fan was found blocked and wasn't spinning. I saw the exhaust fan working and thought all was ok, not even knowing there were more fans. Some models even have another fan inside the optics blocker. I didn't take mine apart that far.

Nov 23, 2008 | Sony XL-2100U Projector Lamp for...

Not finding what you are looking for?
Sony Grand WEGA KDF-50WE655 50" Rear Projection HDTV Logo

Related Topics:

894 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sony Televison & Video Experts


Level 3 Expert

102366 Answers

The Knight
The Knight

Level 3 Expert

74999 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Are you a Sony Televison and Video Expert? Answer questions, earn points and help others

Answer questions