SOURCE: Re GE TFX26ZP sid by side fridge Evaporator coil keep ice on it
the defrost thermostat should be clamped onto the evap coils..defrost timer should be under fridge. If this is a newer model, it might have an ecm ( comp control) on top of the compressor..
SOURCE: Hello, I do have a Refrigerator GE model
When you replaced the fan motor you must also replace the evaporator thermister.
After you replace the thermister,if the fan motor still does not work you must replace the control board on the rear of the refrigerator.
SOURCE: Freezer fan in my GE side by side refrigerator surges and whistle
With you model and brand I would want to check the voltage on the fan and shaft play. Meaning the fan may be going bad or the voltage being altered at the motherboard. I do know your model with the control board that it has if a fan becomes defective the board is also affected. If the fan goes bad and replaced it is very possible that the board will fail and cause the new fan to fail. If you need help with diagnostics please let me know, Thanks, Sea breeze
172 views
Usually answered in minutes!
×