Anonymous Posted on Aug 30, 2013

Repair Fan Blower motor

Amana PTH123B35AE, Mfg. #P1248809R, S/N 0407611643 How do we replace the blower motor on this unit? We have the new part and unit is removed from wall. Also, the outer fan blade is off. Help! What other information do you need?

2 Related Answers

Anonymous

  • 34 Answers
  • Posted on Aug 12, 2009

SOURCE: blower motor not blowing

you will have to replace the blower motor

Ad

B & G Service Co.

  • 5 Answers
  • Posted on Mar 20, 2013

SOURCE: Amana PTAC PTH094E35 fan motors seem periodically unable to get fan turning. Have to sometimes remove the cover and manually spin the fan to get it going.

Check capacitor to be sure it's not weak also if after you push start the fan, if it has a chirping sound, it may have a bearing issue in the motor. Note if you are cleaning the units with a pressure cleaner be extra careful so you do NOT get the motors wet due to some of the smaller motors used in A/C units are moisture sensitive

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Hi I'm Steve... Amana SSE80 Furnace Model GUIC070CA40 MFG # P1229003F Furnace works but air handler blower stops after 5 1/2 minutes, burner continues till high-T limiter triggered (See details)

Motor might be bad and shutting down on thermal protection. Is this a direct drive or belt driven ? .if belt driven try adjusting the belt tension or just replaced the motor
0helpful
1answer

What is the location of power stage/transistor unit on the blower fan on 2001 volvo s80

Volvo Forum • 2000 v70 Blower Motor/Resistor Question - Matthews ...

www.matthewsvolvosite.com/forums/viewtopic.php?p=166169
Jan 8, 2011 - 14 posts - ‎1 author I replaced my blower motor and resistor - with the help and ... On ECC the transistor power stage (referred to as resistor) will shut off blower if the ... the current to blower(voltage level to blower) is controlled by the ECC control unit. ... Hook the negative side of the car battery (or other 12 V source) to the fan. Volvo Forum • S40 fan speed erratic
10 posts
Jul 18, 2013
Volvo Forum • Wanting create a repair procedure for ...
14 posts
Feb 24, 2008
More results from www.matthewsvolvosite.com

All how to replace blower motor in volvo s70 v70 c70 XC70 ...

? 3:03
www.youtube.com/watch?v=frZl49p2quk
Sep 5, 2007 - Uploaded by volvoproject All how to replace blower motor in volvo s70 v70 c70 XC70 ....Awesome video....took 15 mins to install blower motor andresistor on my .... Most time was spent trying to remove theelectrical wires from around the blower properly (there ... I was suprised how much bigger the fan is irl than it looked in this vid!
0helpful
1answer

Air handler blower/fan wont come on.

open it up and vacuum and blow out the fan and other areas
0helpful
1answer

Amana heat pump emergency heat comes on but blower will not start. The call for heat comes in and the heating element(s) glow red for a few seconds and then there is a "click" and the heating...

Check the blower motor capicator. It should be mounted close to the motor with 2 wires to it (brown,brown/white).
Turn the blower on the thermostat and spin the squirrel cage by hand and see if it runs after by itself. If it does then definitely the capicator is bad .If it still doesn't run then check to see if there is voltage going to motor.
If thermostat is calling for fan and there is voltage present at the motor terminal then the motor is bad
0helpful
1answer

19991 civic hatchback. Getting hot air but no

There is a blower motor under the dash, behind glovebox. Loosen 3 retaining screws holding motor housing, drop motor housing and blower motor unit. Replace blower unit. The problem involves the blower resistor. This piece must be replaced but might be easier to replace the entire blower motor unit.
2helpful
1answer

Blower motor not blowing

you will have to replace the blower motor
2helpful
1answer

Amana Air Command 80 blower won't come on

Sounds like fan relay or fan motor possibly capacitor. Call a service tech for free estimate on repair. that wasy you know upfront your cost.Rus
0helpful
1answer

RUUD model URGG-10E31JKR GASS PACK purge fan and main blower

if the purge fan wont start on its own see if there is a capactor attached. if not replace it. more than likely you cannot lube the bearings in your blower motor. the new fans are not serviceable.
Not finding what you are looking for?

42 views

Ask a Question

Usually answered in minutes!

Top Amana Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you an Amana Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...