N37 ingersoll rand 2005. Problem with faults vsd fault 40, power board fault. Compressor doesnt start from ready to start message. After we disconnect few times 12dc connection will run then load, unload, go to unload stop and load again. If we turn off main power compressor want start again showing faults same as before.

Posted by Anonymous on

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 1 Answer

SOURCE: ingersoll Rand SSR compressor shuts down loaded or

When it shuts down, press DISPLAY SELECT button once and use the up down arrows to see the code just before shutdown.

HIGH AIREND TEMP

HIGH AIR PRESSURE

LOW SUMP PRESSURE

PRESSURE OR TEMP SENSOR FAIL

CHECK MOTOR ROTATION

MOTOR OVERLOAD

FAN MOTOR OVERLOAD

STARTER FAULT

I am assuming this has a Intellisys controller.

Posted on Sep 25, 2009

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Plase help!VSD fault 2 Problem with Ingersoll Rand Air Compressors nirvana n37 37kw


Vsd fault 2 is a current imbalance. Check your current readings and compare them to those on the intellysis display they should match, also check for a imbalance in amps. After that it gets more complicated using board diagnostics etc

Sep 12, 2014 | Air Tools & Compressors

1 Answer

Please!!!VSD fault 7 and VSD fault 1 Problem with Ingersoll Rand Air Compressors nirvana n37 37kw. thanks!


Vsd fault 7 is a fault with the hall effect sensors inside the motor, more than likely they will need replacing.

Sep 10, 2014 | Air Tools & Compressors

2 Answers

VSD fault 7 Problem with Ingersoll Rand Air & Gas Compressors nirvana n37 37kw


these compressors are costly even the parts to maintain.I would first check if you cooling fan for the vsd drive is working which is located in the electrical panel of the compressor.A failing fan or one that has failed would cause this fault

Mar 22, 2014 | Ingersoll Rand Air Tools & Compressors

2 Answers

VSD fault 7 Problem with Ingersoll Rand Air & Gas Compressors nirvana n37 37kw


plz any one help us vsd 7 fault and the compressor does not start and the fault appears

Mar 21, 2014 | Ingersoll Rand Air Tools & Compressors

1 Answer

What is a vsp fault 10 alarm Ingersoll rand


A VSD 10 fault is bus oscillation. Quickly rising and falling voltage. Recommend having power company check incoming voltage for oscillation.Voltage can not vary more than 3 percent or alarm is issued.

Mar 09, 2011 | Ingersoll Air Tools & Compressors

Not finding what you are looking for?
Air Tools & Compressors Logo

Related Topics:

32 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ingersoll Rand Air Tools & Compressors Experts

elunsford

Level 2 Expert

210 Answers

Joe Garcia
Joe Garcia

Level 2 Expert

205 Answers

Eddie Tucker

Level 1 Expert

12 Answers

Are you an Ingersoll Rand Air Tool and Compressor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...