SOURCE: Yonan Split Air Conditioning System
F6
ambient temp.
sensor of outdoor
fault
1?Check whether the resistance of sensor is normal,
otherwise replace it.
2?Check whether the sensor wire is short circuit or open
circuit, and whether the plug is well contacted, whether
there is welding off or rosin joint on the electric control
board, repair it if there is any above.
3?When the 1 and 2 are both normal, then the components
or integrated circuit is damaged, the electric control
board should be replaced.
SOURCE: wish to get a manual
Hi harry,
Here are the Manuals you are looking for you need to just look for what exactly you are looking for since the model you gave does not provide any info.
Click this link
SOURCE: my air conditioner is showing f6
this kind of error is: sensor outdoor fualty. 1)check resistance of sensor
2)check the wire sensor for open or short 3) if 1 and 2 are o.k the integrated circuit is faulty.
God bless you
3,762 views