2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 234 Answers

SOURCE: LG error CH 64

What is the model of the unit?

Posted on Apr 07, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

LG air conditioner model number LMN095HVT units keep on flashing with error code CH 46 and with no response at all. How can I fix it? Thanks for your help in advance!


ERROR CH46:
Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor.

Sep 01, 2015 | LG Heating & Cooling

1 Answer

CH-10 error code in LG a/c.Modal-LBUC609RSA5


RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8

Dec 24, 2014 | LG Heating & Cooling

1 Answer

How to fix LG error code CH 23?


There is a problem with a sensor ,but it must to change both(because are 2 senzor )even is broken just one.this senzors are locate in outside unit.

Nov 21, 2013 | LG LSC091PMA Split System Air Conditioner

1 Answer

Lg dehumidifier ch 67 error


Thanks for the post by Posted by Bill L on Jul 14, 2012.
I decided to take a chance and order the new Sensor assembly $20.50 and install it in my LG LD651EBL Dehumidifier which was giving me ch 67 errors. Wala, it worked, the error code is gone and the dehumidifier is now working perfectly! Thanks

Jul 14, 2012 | LG LD651EBL Dehumidifier

1 Answer

LG Artcool about 4 yrs old error code CH 05. no heating or cooling. cheers.


CH 5 on these machines indicates a communications error between the indoor and outdoor units. Generally, it will require a replacement outdoor board assy to repair it. Lookup LG parts on the internet or ring them for your nearest Agent or parts stockist.

Jun 16, 2011 | Heating & Cooling

1 Answer

I have an LG ducted air conditioner and have an CH32 error. Can anyone tell me what this is? Thanks


CH-32 compressor discharge temperature too high. If over 105°C, check refrigerant charge.

Check and rectify the followings:
If over charged-release some gas./If less rpm of fan motor-replace capacitor./Condenser block-Clean it.

Jan 02, 2011 | LG Heating & Cooling

1 Answer

PDP INVERTOR


check with this link.
http://www.tvparts-online.com/index.php?main_page=product_info&products_id=50

Apr 05, 2010 | LG DU-42PX12XC 42 in. Plasma HDTV

1 Answer

LG error CH 64


What is the model of the unit?

Apr 07, 2009 | LG Art Cool LA121CNP wall/window Air...

2 Answers

Error ch 5


check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit......

Dec 09, 2007 | LG LSC183VMA Split System Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

14 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2458 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...