Question about Heating & Cooling

Open Question

Majestic dvr36rn I was told by the company who supplied & installed my 11 yr old fireplace that the valve (gas valve honeywell -nat) part #10001782 ... Needs to be replaced, however, they told me part is no longer avail & in order to repair, they need to replace it with a conversion kit from Paris, Kentucky - they said it would take btwn 3 wks & 6 mos. to get part!!! AND itis expensive! I wonder if anyone knows where I can get this part.

Posted by Anonymous on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 2 Answers

SOURCE: My Majestic DVR36RN gas-log fireplace

Majestic DVR36RN: Here's what you need to do: Verify gas line is open. (You said you already have done that). Next turn the switch to pilot (you said you did that too). Make sure wall switch is on also. Now press and hold the pilot switch and hit the ignitor. Once it lights you need to continue to hold the pilot switch for roughly 1 minute. Release the knob and the flame should stay lighted. Now, turn the knob to on. You should be all set now.

Posted on Dec 14, 2010

Ad
  • 1 Answer

SOURCE: When we built our home

It has a panel hidden under the white fiber hearth bricks at the front bottom of the unit. you need to clean the lava rock off of them, pull both of them up, and then you will see the hidden linear cover that allows you to access the valve and light.

Posted on Jan 13, 2011

  • 4736 Answers

SOURCE: The back panel of our

I assume you have a Majestic Wood Burning fireplace. If that's the case, you have a problem. The first is that Majestic, as such is no longer in business. The second is, if the fireplace is almost 20 years old, they don't make that firebox any longer.

However, since you have a refractory concrete liner, you may can repair it, if the crack is no wider than the thickness of a Dime. There is a high temp mortar that you can purchase from Lowe's or Ace Hardware that comes in a tube. Do not remove the cracked panel from the firebox. Simply clean any loose material from the crack with a tooth brush, being careful not to enlarge the crack. Apply the mortar as directed and it allow it to fully cure before setting another fire. It would also help to clean any debris and ash from the interior of the firebox, before attempting to make the repair. A shop vac equipped with a dust bag works great. It will keep all the dust in the vacuum bag and not blow it throughout the house. You can purchase these from Lowe's or Home Depot. Just match the bag size to gallon size of your shop vac.

If the crack is wider than the thickness of a dime, sadly you're out of luck. Leave the cracked panel in place and consider installing a vent-free or partially vented gas log set. They are rated as supplemental gas heating appliance with no fuss muss or dust to deal with.

Hope this helps solve your problem

Posted on Feb 10, 2011

  • 30 Answers

SOURCE: An air conditioning technician told

Thats very likely, they update and come up with more efficient units and discontinue the older models.
The compressor will lose effieciency over time.

Posted on Jul 29, 2011

farfield
  • 462 Answers

SOURCE: I need to remove my gas fireplace (majestic dvt36rn) in order to remove a dead something behind it (corner install) I can't see any screws and I don't want to just rip at it. A manual would be

usually 1 panel comes off and under it are the screws. look with a good lite up and toward the front from behind the screen or door assy. usually these first screws are located there and are probably black.

Posted on Mar 03, 2012

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I bought an Insta Flame model FSDV 30 direct vent wall furnace, need a natural gas conversion kit. It currently is set up for propane and could use some help in finding the parts and installing them.


There is a ban on that particular furnace as they can explode!

You won't find parts or anyone that will work on it.

[PDF]TSSA Bans Series of Insta-Flame and Northern Flame Fireplaces www.dunnheating.com/.../TSSA%20Bans%20Series%20of%20Insta_Flame%20and%...
  1. Cached
  2. Similar
Oct 23, 2012 - (TSSA) has banned a series of natural gas and propane-fired direct vent ... 'FSDV22' or 'FSDV30' or 'FSDV32' in the model name or number.

TSSA Bans Series of Insta-Flame and Northern Flame ... - CNW Group

www.newswire.ca/.../tssa-bans-series-of-insta-flame-and-northern-flame-fireplaces-51...
  1. Cached
  2. Similar
Oct 23, 2012 - All Insta-Flame and Northern Flame natural gas or propane-fired direct vent freestanding fireplaces with 'FSDV22' or 'FSDV30' or 'FSDV32' in ...

[PDF]Fuels Safety Program DIRECTOR'S ORDER - TSSA

https://www.tssa.org/corplibrary/ArticleFile.asp?Instance=136&ID...
  1. Cached
  2. Similar
Mar 25, 2016 - Natural Gas Fired Direct Vent Free Standing Fireplace - Model ... Insta-flame or Northern Flame: Models FSDV22, FSDV30, FSDV32, D222.

Majestic Fireplace - - Recalls & alerts - Healthy Canadians Website

www.healthycanadians.gc.ca/recall-alert-rappel-avis/hc-sc/2012/15058a-eng.php
  1. Cached
  2. Similar
Nov 9, 2012 - Natural gas and propane-fired direct vent free-standing fireplaces ... Insta-flame or Northern Flame (Models FSDV22, FSDV30 and FSDV32, ...

TSSA Safety Order Ban of Majestic FSDV22, FSDV30 and FSDV32

www.fireplacegroup.ca/tssa-safety-order-ban-of-majestic-fsdv22-fsdv30-and-fsdv32/
  1. Cached
  2. Similar
Dec 21, 2012 - TSSA Safety Order Ban of Majestic FSDV22, FSDV30 and FSDV32 ... CFM Inc. (Majestic Fireplace) and bear the trade names Insta-Flame or Northern Flame ... (a) Natural Gas Fired Direct Vent Free Standing Fireplace - Model FSDV22, FSDV30 ... -Stove shipped as natural gas; LP Conversion Kit included

http://www.healthycanadians.gc.ca/recall-alert-rappel-avis/hc-sc/2012/15058a-eng.php

Dec 11, 2016 | Kitchen Ranges

2 Answers

My Majestic gas fireplace pilot stays lit. But the burner does not light when heat is called for.


Check a safety device called thermopile which the two wires connected to the unit needs to be around 500mV to open gas. This part is between 35-50$ If that is not the problem, you may need to replace unit gas valve.

Oct 10, 2013 | Majestic Fireplaces Majestic Topaz 20ILDV...

1 Answer

Fireplace remote control no longer works correctly


To re-sync your Honeywell 8220 transmitter to the valve: Turn the Local/Remote switch on your valve to Local. Then switch it back to Remote. Within 10 seconds of switching it to Remote, you need to press the Flame button on your transmitter. This will re-sync your transmitter to the receiver in the valve. Replacement transmitters and valves are no longer available for this system, they were discontinued by Honeywell and they are completely out of stock. Monessen Hearth Systems (now owns Majestic, Vermont, etc) has a retrofit kit with a new valve, pilot assy, and remote for these old RF units. (expensive, but cheaper than a new fireplace). FYI, aftermarket remotes are NOT compatible with this Honeywell system.

Nov 24, 2012 | Televison & Video

1 Answer

Need parts for inst-flame gas fireplace---he20rn--#37311


Insta-Flame is now Majestic Fireplaces.
www.majesticproducts.com -> dealer search for your local dealer.

Oct 18, 2012 | Honeywell Q313A1055 Millivolt Thermopile...

1 Answer

When we built our home 6 years ago, Airtron installed a Majestic NVBR36RN vented fireplace system. We had to turn our gas off a while back and never thought about the fireplace until now when we wanted to...


It has a panel hidden under the white fiber hearth bricks at the front bottom of the unit. you need to clean the lava rock off of them, pull both of them up, and then you will see the hidden linear cover that allows you to access the valve and light.

Dec 02, 2010 | Heating & Cooling

1 Answer

My Majestic DVR36RN gas-log fireplace insert will not start. No ignition when striker is depressed, no flame lit at all. Gas inlet line open, pilot switch to "pilot" as directed. Maybe...


Majestic DVR36RN: Here's what you need to do: Verify gas line is open. (You said you already have done that). Next turn the switch to pilot (you said you did that too). Make sure wall switch is on also. Now press and hold the pilot switch and hit the ignitor. Once it lights you need to continue to hold the pilot switch for roughly 1 minute. Release the knob and the flame should stay lighted. Now, turn the knob to on. You should be all set now.

Nov 09, 2010 | Heating & Cooling

2 Answers

GAS FIREPLACE


Yes, hopefully changing the thermocouple (skinny sensor) or thermopile(fat sensor) would do the trick.
Start with these fairly inexpensive repairs first.
Unfortunately if the honeywell valve is bad a new one can be expensive.
Also it is hard to order parts from Majestic, they just went bankrupt, not to long ago and Martin is taking them over. You might look for your valves model# and check online for other suppliers of that model# or ask for a compatible Direct Vent gas valve that's not as problematic. (eBay and HVAC dealers, etc.)
FYI:
You said it's been about 5 years, you might decide it's less of a hassle to have new gas fireplace installed. Martin and Empire are probably two of the best, with 5 year parts and labor warrantys.
Hope you find some success in your endeavor.

Dec 10, 2008 | Honeywell Electronic Programmable...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

229 people viewed this question

Ask a Question

Usually answered in minutes!