Question about Heating & Cooling

Open Question

Ramsond fc code on ramsond ductless ac model cmvs-25v9a-a27a

Posted by Anonymous on

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 73 Answers

SOURCE: my amcoraire mini split ductless

Support@Pridiom.com
201-266-8234 option 2

Posted on Sep 02, 2011

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How close to the ceiling can the inside head be


Hello, try at least, 2 inches, because the interior unit takes air from upside.

Sep 16, 2014 | Ramsond 18,000 BTU 1.5 Ton Ductless Mini...

1 Answer

Leaking water from the inside unit


When the air gets cooled it also gets dehumidified, on the inside unit there should be a condensate drain. Check the drain to see if its clogged, also check to see there is a drain, I have seen units installed by "pros" who have forgot to intall it

Apr 14, 2014 | Ramsond 12,500 BTU 1 Ton Ductless Mini...

1 Answer

Newly installed, the outside unit will not run but the fan on inside will run


checkto see if your getting 24voltsat the condensers control wire and chech for power voltage

Jan 08, 2013 | Ramsond 12,500 BTU 1 Ton Ductless Mini...

1 Answer

Part Board PFC70 (ZB102B9129) shorted out. model # AOM243HX mini split AC component. Where can I get one?


Ramsond has this board in stock. Contact tech support/parts at 866-777-7071

Jun 01, 2011 | Kitchen Ranges

1 Answer

MY RAMSOND MINI SPLIT HIGH PRESSURE LINE IS FROZEN EVERY TIME I TURN THE UNIT ON


The expansion valve or the capillar tubes are inside the condenser and the gas (freon) is already expanded right outside the condensing unit all the way to the evaporator and beacause the diferential of temperature between this copper line (which is not high pressure anymore) and the outdoor air , there's condensention that freezes up.

Oct 15, 2009 | GE Quiet-Aire Ductless Split System Air...

1 Answer

I am concerned the wiring diagram provided for a Ramsond 12000 btu split system 240 volt is wrong. (1 2 3 N L L N) I assumed the L's were slots for the hot legs.


Those terminals on a ductless split are reserved for the communication wires from the out door to indoor unit. L L N should be line 1, line 2, and neutral (ground) there should be a 1 2 3 N terminal block in the indoor unit also, those terminals would most likely be for the communication between the two units.

May 17, 2009 | GE Quiet-Aire Ductless Split System Air...

1 Answer

Ramsond a/c trouble code E7


Indoor/outdoor communication, you can check the connecting cable may have damage.

Dec 17, 2008 | GE Quiet-Aire Ductless Split System Air...

1 Answer

Ramsond split AC 12000


HI YOUR BROBLEM I THINK IS THE SENSOR FOR THE ROOM TEMP

Sep 02, 2008 | GE Quiet-Aire Ductless Split System Air...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

65 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

2597 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...