Older motor had wires labeled T1, T2, T3, T4, T5, T8. New motor has wires color coded. How can I know which colors go with the old labels?

Posted by Anonymous on

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 8 Answers

SOURCE: Hi I have a farm

there is normally a name plate on the inside of the cover that shows high and low voltage connections without that the connections could be a couple different ways. Have a look Im sure its there

Posted on Jan 21, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Which is the right partner of T1? IS THE T7? OR THE T4/ OTHER T2.IS THE T8 OR THE T5?


One needs to know what the voltage and phase(1 or 3) the unit is and what the power supply is.

Apr 12, 2015 | Hobart H600 Stand Mixer

1 Answer

I need ang diagram for hobart mixer 9 out wire T1/T2/T3 AND T4/T5/T6, T7/T8/T9 which is the right partner of t1/t2/t3???


Having 9 wires means it is a 3 phase motor.
For 220 to 240 Volts - L1, T1 and T7 go together. L2, T2 and T8 go together. L3, T3 and T9 go together. T4, T5 and T6 go together.

For 440 to 480 Volts - L1 and T1 go together. L2 and T2 go together. L3 and T3 go together. T4 and T7 go together. T5 and T8 go together. T6 and T9 go together.

Apr 12, 2015 | Hobart Food Mixers

1 Answer

How do i rewire a broomwade 3 phase compressor 1970


Rewire for ?? High voltage motor wiring is L1-T1, L2-T2, L3-T3, T4-T7, T5-T8, T6-T9. Low voltage is L1-T1-T4, L2-T2-T5, L3-T3-T6. The motor protection overloads will need to be sized accordingly, to the motor's FLA ( full load amps) for the voltage used. The control needs to be looked at also, if there is a control transformer, the transformer needs to be wired or repaced for the new supply power voltage used.

Mar 12, 2015 | Air Tools & Compressors

1 Answer

Need to know what wire goes to were..on a smith & jones modle 67841 compresser motor..p1 p2 t2 t3 t4 t5 t8..to what wire black white green


Hey guys, this motor is reversible. I have it wired to turn clockwise(according to diagram),
green to ground;
L1 (black) to P1;
L2 (white) to T2-T4-T8;
P2-T3-T5 together .
When I plug it in, the motor turns counter clockwise and the on/off switch does not work. How do I fix?

Oct 27, 2012 | AO Smith A O Smith Motors Centurion 1.5hp...

1 Answer

Wiring diagram for 230v


Single phase motor for 230V, connect T4 and T5, to one line. T2, T3, T8 common connected. T1 to other line. Check Rotation, This should be for CCW rotation facing output shaft. Swap T5 and T8 for CW rotation.

Jan 17, 2011 | Ingersoll Rand TS4N5 Ir Electric...

1 Answer

How to conect 3 phase motor 9 yellow wires from p1


Connect t4,t5,t6 together. Connect t1,t7 together for line 1. Connect t2,t8 together for line 2. Connect t3,t9 for line 3.

May 23, 2010 | Omega 5hp 1740RPM 184TC Frame 230 Volts...

1 Answer

I have a doerr electric motor, lr22132 single phase 220v, 3/4 HP with wires t2, t3, t4, t5, t6, t7, t8 and earth, how do i hook up, any help would be great, paul


i have a doerr electric motor, lr22132 single phase 220v, 3/4 HP with wires t2, t3, t4, t5, t6, t7, t8 and earth, how do i hook up, any help would be great,

Nov 20, 2009 | Kitchen Appliances - Others

1 Answer

Need wiring diagram for 3 phase electric motor


motor leads on a three phase are T1, T2, T3, T4, T5, T6, T7, T8, T9. for high voltage [480] L1 to T1, L2 to T2, L3 to T3, connect together and tape - T4-T7, T5-T8, T6-T9. For LOW voltage [240] L1 to T1 & T7 & tape, L2 to T2-T8 & tape, L3 to T3 & T9 & tape. T4-T5-T6 together and tape.

Oct 20, 2009 | Saws

1 Answer

Hi I have a farm duty 1/2 hp dual voltage, single phase, capaciter electric motor. I simply want to attach a plug for 110. My problem is there are 9 wires colored and Labeled as follows Y/Black- P1 Br- P2...


there is normally a name plate on the inside of the cover that shows high and low voltage connections without that the connections could be a couple different ways. Have a look Im sure its there

Jan 21, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

44 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2458 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...