Did you transport it STANDING or LYING down?
If Standing 4 possibilities:
1. The thermostat is hosed (replace)I had one like this and just put it on a $6.00 24hr time to turn on for 1hr every 5 hrs. (New Thermostat was $40.00)
2. The heat exchange fins on the back are dirty(clean with broom and air/vacuum cleaner)
3. The Door seals arent sealing and cold air is falling out the bottom, pulling hot air in the top (rehang door or replace seal) Note: a piece of paper 2" by 8" should be hard to pull out all the way around when closed. Like a cash register reciept. Cleaning with armor-All and then thinly coating with Vaseline may help
4. The Freon is shot and needs a recharge. (Costs $40-100.00)
If transported Lying down, there is now air in the lines and it needs to stand OFF for 24hrs. You may have hosed the pump with the air/freon mix, but let it stand so the air can surface and retry
241 views
Usually answered in minutes!
×