Haier HDN655E unit runs but compressor won't kick in

I have a Haier HDN655E that worked well for over a year but lately I've been having problems with it where the unit turns on and the fan blows but the compressor will not kick in. I've set the desired humidity anywhere between 30-50 and it shows the current humidity around 60-70 but the compressor will not engage and dehumidify the air. I've opened it up and don't see any loose wires or anything but I don't know what to look for and I can't find any service manual for the unit. Any help is greatly appreciated. Thanks in advance!

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points


    An expert that got 10 achievements.


    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 625 Answers
Re: Haier HDN655E unit runs but compressor won't kick in

Use a jumper cord and go directly to the compressor to see if it will run. if it don't run, open up the motor box and see if there is a klixon overload inside. this should be normally closed. if it isn't replace it. the klixon is a thermal overload cutout. it usually trips because of high winding temperatures and protects the motor inside. the compressor is a hermetically sealed unit. no, or little freon will cause the motor to overheat.

Posted on Aug 21, 2007

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

I have an haier hd456e. The unit turns on and the control panel set humidity shows Hi. The compressor does not go on and no water shows up in the bucket. Could this be the 15 amp fuse -- I pulled it and...

I suspect from what you have described, that the humidity extraction level is set to high. Lower it (Arrow Down) to 30-32%. If the filter is clean and the water collection bucket is installed properly, the unit should start working, shortly there after.

To assist you further, I have included a link to the Owner's Manual for your unit. Just in case you have misplaced yours. You can download and print the manual for future reference.

I hope this helped you. Please let me know. Thanks.

Jun 17, 2011 | Haier HDN655E Dehumidifier

1 Answer

The unit keeps popping the breaker on the electric line.

Hi, The compressor has failed..

There are many reasons why a dehumidifier willnot work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrongwith their dehumidifier

Dehumidifier is running but no water is in bucket




Feb 15, 2011 | Haier HDN655E Dehumidifier

1 Answer

Haier HDN655E - water does not drain out of hose

check the hose connection,when new these units have a knock-out plug where the hose goes so if your only going to use the bucket and not the hose it wont run out the hose connection

Aug 01, 2010 | Haier HDN655E Dehumidifier

1 Answer

Fan runs only compressor won't kick in

there must be a freon leakage on your aircon. try a leak test. try some aircon cleaning too. hope this helps

Jul 03, 2009 | Haier HDN655E Dehumidifier

2 Answers

Dehumidifier Brand haier HD456E does not pull water and the tank is empty, after 24 hours of running with water on wood floor. Can't find manual or online info for this model.

I have 3 HD656E Haier Dehumidifier with the same problem runs but no water in bucket. How many did the Haier company make with this problem?

Apr 12, 2009 | Haier HD656E Dehumidifier

1 Answer

I just purchased a new Haier 65 pint dehumidifier and inside on the bottom of the unit, it is covered in oil. Of course the unit is not functioning (it runs but is not removing any water).

This sounds to me like a leak in the compressor housing which has allowed the oil and refrigerant to escape. I would take it straight back to the seller and request a replacement unit.
Hope this helps. D.

Jul 16, 2008 | Haier HDN655E Dehumidifier

1 Answer

Where can I find the fuse on the panel? on the internet, you can purchase a 10 pack of 250volt 12amp fuses. AG-12

Jul 14, 2008 | Haier HDN655E Dehumidifier

1 Answer

Kenmore Dehumidifier

if the compressor is running it sounds like a refrigerant problem or dead compressor in both cases its not cost efective to repair dan

Jul 05, 2008 | Haier HDN655E Dehumidifier

Not finding what you are looking for?
Haier HDN655E Dehumidifier Logo

397 people viewed this question

Ask a Question

Usually answered in minutes!

Top Haier Dehumidifiers Experts


Level 3 Expert

6993 Answers


Level 3 Expert

3283 Answers

Shawn DuRee

Level 3 Expert

353 Answers

Are you a Haier Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides