Question about Mitsubishi VS-50707 50" Rear Projection Television

1 Answer

TV turns off right away relay clicks

Folks, I have a Mitsubishi 50" VS-50707. Many a times it shuts down while viewing. Then it does not come on. When I attempt to turn it on either by remote or Power button on the panel, it comes on and shuts right back off and the relay clicks once. I put it into the diagnostic mode by pressing the input and menu button on the panel simultaneously and it gave me an error code of 24 - vertical delfection failure. I looked for dry solder on the board and resoldered the filter capcitors and the STRF6682 (IC 951)in the Power supply area. Is there a swithcing capacitor that I need to look for/replace? Where is the vertical IC located on this TV set and what numbers are they usually are. The TV does come back on after a hard reset (that is leaving the Power disconnected for more that 4 hours) then it functions for a few days probably a week and then it gets back into this mode. Any help from the TV Master Serviceman would very much be appreciated. Thanks!!!

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Master
  • 1,153 Answers

1. MAY BE INTERMITTENT, SELF-DIAGNOSIS ERROR 23 OR 24. CHECK SOLDER CONNECTIONS AT CONNECTOR "DY" ON THE YOKES. 2. SHUTDOWN AT POWER WITH SELF-DIAGNOSIS ERROR 23 OR 24. CHECK C411 2200 UFD 35 V AND C412 10 UFD 50 V, BOTH LOCATED ON THE MAIN PCB.

Posted on Aug 27, 2007

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a Mitsubishi 50" Big Screen Model VS-50707. When trying to turn it on, it blinks once and clicks, then doesn't turn on. It has been doing this for a while, but eventually would come on and need some...


The picture tubes are warn out or the deflection circuit is failing. The power supply is struggling to fire them up. Takes a lot of power.
Some TV shops have the know how to replace the tubes. About $1000 parts and labor.

Dec 30, 2009 | Mitsubishi VS-50707 50" Rear Projection...

1 Answer

When I turn the tv on it turns off again right away


mine did the same thing then when we got it to stay on the picture was all messed up, and we;re hearing it will be quite a repair bill!

Nov 08, 2009 | Mitsubishi VS-50707 50" Rear Projection...

1 Answer

Tracking on my tv Mitsubishi 50707 50in


i have the same tv cant fix the tracking .model 50707 mitsibishi

Dec 26, 2008 | Mitsubishi VS-50707 50" Rear Projection...

2 Answers

Mitsubishi VS-50707 shuts down sporadically


you can do a self-diagnosis test by pressing the menu and input/device button on set for 5 sec and see what error code it gives you. Count the blinks followed by a short pause then more blinks. This is the error code.

Mar 10, 2008 | Mitsubishi VS-50707 50" Rear Projection...

1 Answer

Mitsubishi VS-50707


Check the CRT socket of the tube that is arching. Could be a solder connection or shorted CRT. If you need further assistance let me know.

Feb 03, 2008 | Mitsubishi VS-50707 50" Rear Projection...

1 Answer

Mitsubishi vs 50707 50 inch projection tv problem


on the signal board replace the caps by the 5/9 volt regulators. c2p04 is the main culprit. 6 caps in total can be changed. I believe c2p05 also.

Dec 15, 2007 | Mitsubishi VS-50707 50" Rear Projection...

1 Answer

VS 50707 turns on, then off immediately


on the signal board replace the caps by the 5/9 volt regulators. c2p04 is the main culprit. 6 caps in total can be changed. I believe c2p05 also.

Dec 10, 2007 | Mitsubishi VS-50707 50" Rear Projection...

1 Answer

Mitsu. VS-50707 problems


12 = No error detected, check power supply.
check all your voltage coming out of the power supply and check the fuses.

Dec 10, 2007 | Mitsubishi VS-50707 50" Rear Projection...

1 Answer

50707 does not turn on, goes off immediately code 24, relay clicks


1. MAY BE INTERMITTENT, SELF-DIAGNOSIS ERROR 23 OR 24. CHECK SOLDER CONNECTIONS AT CONNECTOR "DY" ON THE YOKES. 2. SHUTDOWN AT POWER WITH SELF-DIAGNOSIS ERROR 23 OR 24. CHECK C411 2200 UFD 35 V AND C412 10 UFD 50 V, BOTH LOCATED ON THE MAIN PCB.

Aug 27, 2007 | Mitsubishi VS-50707 50" Rear Projection...

Not finding what you are looking for?
Mitsubishi VS-50707 50" Rear Projection Television Logo

275 people viewed this question

Ask a Question

Usually answered in minutes!

Top Mitsubishi Televison & Video Experts

matt martin
matt martin

Level 3 Expert

1213 Answers

The Knight
The Knight

Level 3 Expert

75178 Answers

Jaime Hernandez

Level 3 Expert

2335 Answers

Are you a Mitsubishi Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...