By kioner - usenet poster
I have an Overland data TX8 Pertec controller I am trying to get running
with an Qualstar 1052 9 Track Tape drive,
There is a bank of 8 dip switches that control the controller base address,
however I have zero documentation to go with the card.
If you have docs for these switches please reply to:
jav1 (at) fmtc.net
Thanks!!
Solution #1
posted on Aug 04, 2005
Odud - usenet poster
Rank:
Apprentice
Rating: 0%, 0 votes
Rating: 0%, 0 votes
There are two types of switches used over the years. One labeled 12345678 and
one labled 87654321. In both cases ON is towards the printed switch number.
Address 360 is the factory default.
DIP SW 1 2 3 4 5 6 7 8
Address Line A10 A9 A8 A7 A6 A5 A4 A3
360 X X X X
300 X X X X X X
310 X X X X X
320 X X X X X
330 X X X X
340 X X X X X
350 X X X X
Delete "zzz" from e-mail address to respond to this message. Please do not spam
me.
one labled 87654321. In both cases ON is towards the printed switch number.
Address 360 is the factory default.
DIP SW 1 2 3 4 5 6 7 8
Address Line A10 A9 A8 A7 A6 A5 A4 A3
360 X X X X
300 X X X X X X
310 X X X X X
320 X X X X X
330 X X X X
340 X X X X X
350 X X X X