Question about Heating & Cooling

Open Question

Hi, my rinnai granada mk11 won't stay alight. Haven't used it for 3 years but was fine last time used. The pilot will light but there seems 2 b a problem with the gas lighting or starting the 3 element things & the flame keeps dying out.

Posted by Anonymous on

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 4736 Answers

SOURCE: My Rinnai Granada Mk11

There are a several of things that can cause this problem:

1. The Oxygen Depletion Sensor (ODS) is clogged and reads the Oxygen Level in the room as
Unsafe for Operation. Solution: Clean the ODS, which is part of the Pilot Assembly With canned
compressed & a straw nozzle (like you clean your computer with). It will require some dis-
mantling of your heater,

2. Once Pilot is lit, not waiting long enough for the Thermopileto heatup, before pushing the Medium
button. Allow pilot to burn at least one minute, before switching to any heat selection.

3. Gas pressure problem. Have the gas pressure to the unit checked, as well as the gas pressure
at the gas control valve, while unit is in operation.

If you continue to have this problem after completing the Solution in # 1. Call the Rinnai Helpline
1 300 366 388 or contact your local Rinnai Dealer, who you purchased the unit from.

If you have misplaced your Owner's Manual, here's a link to it, that you can download and print for future reference.

http://www.rinnai.com.au/images/stories/operating_instructions/Heating/Portables/Granada252/portable_radiant_convectors.pdf

I hope this helped you troubleshoot and solve the problem. Please let me know. Thanks.

Posted on Jun 17, 2011

  • 1 Answer

SOURCE: My Rinnai Granada Mk11

our rinnai grenada mk11 will not contiue to run after release of button. pilot light is still on

Posted on Jun 25, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Is there an adjustment to have pilot light stay on after given length if time. Our rev oven pilot takes longer then one minute. About 1 1/2 min


No it is a safety feature that the pilot has to heat up the thermocouple to assure the main gas valve that the pilot is alight and hot.

Dec 05, 2016 | Ovens

1 Answer

Propane wall heater


Clean pilot , Then check thermocouple if it is not staying alight .

May 03, 2017 | Heating & Cooling

1 Answer

Hello My Heater Rinnai Granada 25 is very hard to start, I need to hold the button for quite a while and let it up very slowly ,if I am lucky it will stay a light. Thanks Pepe.


Pepe, this is generally a sign that either the pilot is dirty or the Thermocouple is starting to fail .I'd bet on the Thermocouple. This is an issue that will have to be solved by an authorized Rinnai Service Technician. Which would be the dealer the heater was purchased from.

Hope this helped and thanks for choosing FixYa.

Jul 29, 2011 | Heating & Cooling

2 Answers

My Rinnai Granada Mk11 Portable Gas Heater starts well but the flame goes out when I press Medium Heat.


There are a several of things that can cause this problem:

1. The Oxygen Depletion Sensor (ODS) is clogged and reads the Oxygen Level in the room as
Unsafe for Operation. Solution: Clean the ODS, which is part of the Pilot Assembly With canned
compressed & a straw nozzle (like you clean your computer with). It will require some dis-
mantling of your heater,

2. Once Pilot is lit, not waiting long enough for the Thermopileto heatup, before pushing the Medium
button. Allow pilot to burn at least one minute, before switching to any heat selection.

3. Gas pressure problem. Have the gas pressure to the unit checked, as well as the gas pressure
at the gas control valve, while unit is in operation.

If you continue to have this problem after completing the Solution in # 1. Call the Rinnai Helpline
1 300 366 388 or contact your local Rinnai Dealer, who you purchased the unit from.

If you have misplaced your Owner's Manual, here's a link to it, that you can download and print for future reference.

http://www.rinnai.com.au/images/stories/operating_instructions/Heating/Portables/Granada252/portable_radiant_convectors.pdf

I hope this helped you troubleshoot and solve the problem. Please let me know. Thanks.

Jun 17, 2011 | Heating & Cooling

1 Answer

Rinnai gas log heater (royale) keeps cutting out. now it wont stay on at all. the ignition is fine, the gas flow seems fine and the fan works fine. we vacuum the dust out regularly


When you say "it won't stay on at all." Do you mean the burner and the pilot flame shut off together or does the pilot remain lit? Is the unit showing any Fault Codes on the LCD display?

Apr 03, 2011 | Rinnai Heating & Cooling

1 Answer

We have a Rinnai 2000D heater. The pilot light goes out and is then difficult or impossible to restart. The igniter is working and there is the smell of gas, just doesnt seem to be enough gas there to...


you can try cleaning the pilot light with sand paper, (where the hole in the end is where the gas comes out) they get carbon built up over time and causes the hole to get smaller which makes the pilot light not want to stay light because of the small amount of gas coming out.

Sep 25, 2010 | Rinnai Heating & Cooling

1 Answer

Have an old Rinnai Gas Heater (approximately 30 years old) still working well, but we had to turn off the gas, and now cannot turn it on again. We have two buttons, one below the other, one is red and...


You are half-way right, to light the pilot, light it and push down the red button and hold it for at ----least2-minutes-- till the flame heats up the pin (thermocouple- which fire-thermocouple metal makes electricity which sends it to the gas valve and says ,OK GAS VALVE,I'VE GOT A PILOT FLAME SO OPEN UP THE MAIN GAS VALVE! See where I'm going with this?

Sep 03, 2008 | Rinnai Heating & Cooling

1 Answer

Infared heater


When was the last time you cleaned the pilot? In your owners manual there is a cleaning procedure. If you can't find the manual, go to www.rinnai.us. You may be able to download one from their site.

Dec 18, 2007 | Rinnai Desa Vent-Free Infrared Gas Heater:...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

58 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2463 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides