Question about Precor EFX 546i Elliptical Version 4

1 Answer

Precor error 12 - Precor EFX 546i Elliptical Version 4

Posted by Anonymous on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Precor Master
  • 914 Answers

Precor Error 12, Watchdog (Lower PCA) Probable Cause 1. A failure in the lower PCA overloads the low voltage power supply and causes it to drop below the preset level.
2. A fault in the interconnect cable (upper PCA to lower PCA) causing the low voltage power supply of the lower PCA to be too low.
3. A failure in the upper PCA that overloads the lower PCA low voltage power supply causing it to be too low.
Corrective Action

  1. If the error message is continually displayed when the unit is powered up, the upper PCA needs replaced.
    External causes may make the error appear intermittently.
    1. If the AC input of the unit dips significantly during power up test sequences, the test could fail causing the error to appear.
    2. A treadmill connected to a non-dedicated AC circuit can experience this error intermittently.
  2. Determine if the interconnect cable is the cause by substituting a know good cable in place of the current cable. For test purposes, the substitute cable needs to be connected directly between the upper and lower PCA's, without routing the cable internally.
  3. Determine if the upper PCA is the cause by substituting a know good upper PCA for the existing upper PCA.
Precor Error Code 12 12 Watchdog Lower PCA

Posted on Jul 28, 2014

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Precor error 3


Precor Error 03, Memory, RAM, EEPROM Test Error Probable Cause This error message almost always indicates an upper PCA problem when it is consistently displayed. Failures causing this error message to be displayed are rare.
Corrective Action If the error message is consistently displayed when the unit is powered up, the upper PCA should be replaced. It is possible to see this message displayed intermittently due to external causes. If the units A.C. input significantly dips during the power up test sequence the test could fail resulting in this message being displayed. Treadmills operating on non-dedicated A.C. circuits may see this message displayed on an intermittent basis. Precor Error Code 03 E03 EEPROM Test Error

Feb 22, 2014 | Precor Exercise & Fitness

1 Answer

Error41


Precor Error 41, Lift has not Responded in Acceptable Time Probable Cause Error 41 was present in early software versions and is no longer being used.
Corrective Action If you encounter a unit that has software with an error 41, diagnose the same way you would if getting an error 40.
Precor Error 41

Jan 29, 2014 | Precor 9.21 Treadmill

1 Answer

Error codes for 9.17


This link will take you to some common error codes found on most Precor exercise machines:


Error Code List for Precor Fitness Equipment

Dec 12, 2013 | Precor Exercise & Fitness

1 Answer

Precor treadmill code e3 is on


Precor Error 03, Memory, RAM, EEPROM Test Error Probable Cause This error message almost always indicates an upper PCA problem when it is consistently displayed. Failures causing this error message to be displayed are rare.
Corrective Action If the error message is consistently displayed when the unit is powered up, the upper PCA should be replaced. It is possible to see this message displayed intermittently due to external causes. If the units A.C. input significantly dips during the power up test sequence the test could fail resulting in this message being displayed. Treadmills operating on non-dedicated A.C. circuits may see this message displayed on an intermittent basis. Precor Error Code 03 E03 EEPROM Test Error

Oct 18, 2013 | Precor C954 Remanufactured Treadmill

1 Answer

Precor error code 1


Precor Error 01, Memory, RAM, EEPROM Test Error Probable Cause This error message almost always indicate an upper PCA problem when they are consistently displayed. Failures causing this error message to be displayed are rare.
Corrective Action If the error message is consistently displayed when the unit is powered up, the upper PCA should be replaced. It is possible to see this message displayed intermittently due to external causes. If the units A.C. input significantly dips during the power up test sequence the test could fail resulting in this message being displayed. Treadmills operating on non-dedicated A.C. circuits may see this message displayed on Precor Error Code 01

Aug 18, 2013 | Precor 9.21 Treadmill

1 Answer

Error code 1 and 3 on my Precor 9.21s treadmill?


Precor Error 01, Memory, RAM, EEPROM Test Error Probable Cause This error message almost always indicate an upper PCA problem when they are consistently displayed. Failures causing this error message to be displayed are rare.
Corrective Action If the error message is consistently displayed when the unit is powered up, the upper PCA should be replaced. It is possible to see this message displayed intermittently due to external causes. If the units A.C. input significantly dips during the power up test sequence the test could fail resulting in this message being displayed. Treadmills operating on non-dedicated A.C. circuits may see this message displayed on an intermittent basis. Precor Error Code 01

Precor Error 03, Memory, RAM, EEPROM Test Error Probable Cause This error message almost always indicates an upper PCA problem when it is consistently displayed. Failures causing this error message to be displayed are rare.
Corrective Action If the error message is consistently displayed when the unit is powered up, the upper PCA should be replaced. It is possible to see this message displayed intermittently due to external causes. If the units A.C. input significantly dips during the power up test sequence the test could fail resulting in this message being displayed. Treadmills operating on non-dedicated A.C. circuits may see this message displayed on an intermittent basis.
Precor Error Code 03 E03 EEPROM Test Error

Mar 27, 2013 | Precor 9.21s Treadmill Display Console...

1 Answer

Error 12 appears on display? What do I do?


Precor Error 12, Watchdog (Lower PCA) Probable Cause 1. A failure in the lower PCA overloads the low voltage power supply and causes it to drop below the preset level.
2. A fault in the interconnect cable (upper PCA to lower PCA) causing the low voltage power supply of the lower PCA to be too low.
3. A failure in the upper PCA that overloads the lower PCA low voltage power supply causing it to be too low.
Corrective Action
  1. If the error message is continually displayed when the unit is powered up, the upper PCA needs replaced.
    External causes may make the error appear intermittently.
    1. If the AC input of the unit dips significantly during power up test sequences, the test could fail causing the error to appear.
    2. A treadmill connected to a non-dedicated AC circuit can experience this error intermittently.
  2. Determine if the interconnect cable is the cause by substituting a know good cable in place of the current cable. For test purposes, the substitute cable needs to be connected directly between the upper and lower PCA's, without routing the cable internally.
  3. Determine if the upper PCA is the cause by substituting a know good upper PCA for the existing upper PCA.

Precor Error Code 12 12 Watchdog Lower PCA

Jul 12, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

What is error 50 on the precor efx546


Error 50, Too Much Brake (Magnet) Current
The problem maybe lower board related or improper signal is being translated Call Precor @ 800-347-4404

May 11, 2010 | Precor EFX 546i Elliptical Version 4

1 Answer

What is error 50 on the precor efx546


Precor uses the same error codes for all of their units. Error code 50 is for excessive brake (eddy current magnet) current.

Mar 19, 2010 | Precor EFX 546i Elliptical Version 4

Not finding what you are looking for?
Precor EFX 546i Elliptical Version 4 Logo

102 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Electro Med Services...
Electro Med Services...

Level 3 Expert

6694 Answers

Howard
Howard

Level 2 Expert

115 Answers

Shehu Pro
Shehu Pro

Level 3 Expert

1284 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...