Question about Pentair Mastertemp Heater

1 Answer

Mastertemp 400 NG heater - unused gas smell when firing

Whenever we turn on our pool heater, there is a smell coming from the heater that smells like gas. The gas company has determined it to be unused gas, not a leak. The pool company that installed the pool orders mastertemp heaters set up for lg and then if you want ng, you have to have it converted - this was done by the gas company when it was installed. Well, that's what they said was done. Why do we have this smell?

Posted by Anonymous on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Diehard:

    Visited the website for 60 consecutive days.

  • Expert
  • 116 Answers

Ask the gas company for the conversion kit part part number they used.

Posted on Jul 12, 2017

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 990 Answers

SOURCE: I have a Pentair Mastertemp 250 pool heater with

This is an ignition flame falure code. Could be you don't have gas getting to the pilot, no spark to ignite the pilot or your ignition is not reading the flame. Sorry to say but it's probally time to get the pool guy out to look at it. Good luck.

Posted on Apr 15, 2010

  • 990 Answers

SOURCE: heater cycles on / off

This could be a water flo problem. you need to chech to be sure your by-pass valve is closed down enough to force water threw heater, There is a internal by-pass that could be a problem also, or a bad pressure switch. If the by-pass isn't the problem then you should check these also.

Posted on Jul 26, 2010

  • 1 Answer

SOURCE: getting a E05 code on my Mastertemp pentair

I have same problem. Mechanic not sure what to do. May need a new board.

Posted on Jul 31, 2010

adamh294
  • 310 Answers

SOURCE: Pentair MasterTemp 400 Heater Will run fine for

This reminds me of some of the High temp sensors ive replaced. I would start with checking the pumps flow to the heater. Make sure there are no abstructions and at least 35 GPM (gallons per minute) running to the heater. If your flow is too low, you will trip the high limit sensor after a short while.
This could also mean you need to clean out the heat exchanger. When an exchanger gets dirty, it blocks the flow of water, slowing it down and "super heating" itdue to the water being in contact with the exchanger for too long. This will also trip the high limit and call for service.
If both the above items check out, contact me @ adamh@newconceptchem.com and I will guide you further.

Posted on Nov 23, 2010

adamh294
  • 310 Answers

SOURCE: My mastertemp heater has a error 5 reading. Heater

This sounds like the flame rectifier (flame sensor) Below is a link to the manual to trace the part and also to get the part number.
http://pentairpool.com/pool-pro/manuals/section.php?s=28

Posted on Jan 20, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

MasterTemp 400K BTU heater kicks on for 20sec. and starts shaking, then turns off and repeat itself. Everytime it kicks on we smell gas as well. Water flow seems to be OK in spa and pool.


Even though you are smelling gas it could mean the gas flow is not strong enough.
When you say the water flow seems good, have you cleaned your filter recently?

If you are somewhat handy you can troubleshoot this heater by taking off the front panel turning it on and looking up to the back of the circuit board.
When it shuts off it will have red lights next to abbreviated words such as hl1 hl2.

Whichever light or lights are red will point you in the right direction of the cause.

Mar 27, 2017 | Pool & Spa

1 Answer

Mastertemp 400 heater won't fire


what is it doing, what is not doing?
What error messages, if any?

Jun 22, 2014 | Pentair Mastertemp Heater

1 Answer

Laars Lite 2


If the heater is "acting normal" with no failure codes and you smell gas, then I would bet it's the igniter. The fact that you smell gas indicates the heater does not have a failure in any of the safety circuits and wants to fire. It is just missing an ignition source or the gas you smell is not making it to the proper place to be ignited. Given these two options it is most often the igniter. Replacing the igniter is not difficult but it is a VERY delicate part and experience in handling it is benificial.

Apr 14, 2014 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

I have a mastertemp 250k heater,Just replaced heater core all the gaskets, Rebuilt the unit. I am trying to dry fire the system to check the blower system their is no gas hooked up to the system or water I...


Yes, yo cannot "dry fire" a water heater. There are several safety measures in place to prevent this. If you were to successfully "dry fire" your pool heater, you would most likely have to rebuild it again.

Aug 04, 2011 | Pentair Mastertemp Heater

1 Answer

My mastertemp heater has a error 5 reading. Heater starts, then it shuts down after about 10-20 seconds.


This sounds like the flame rectifier (flame sensor) Below is a link to the manual to trace the part and also to get the part number.
http://pentairpool.com/pool-pro/manuals/section.php?s=28

Jan 20, 2011 | Pentair MASTER TEMP HEATER 400 000 BTU NG...

1 Answer

Moved heater from one pool to another an now its not working the induce draft is running an the igniter is glowing an the gas valve opens an you can smell gas so now what


You will need to check the size of the gas line. These heaters work on gas volume more than pressure. For a 400,000 any thing more than 30-50 foot you will probably need at least 1.5 to 2 inch supply line. It is always good to go big on the line to allow for other gas appliance's. I would check this first it is a common problem when upgrading to Low Nox.

Oct 20, 2010 | Pentair MASTER TEMP HEATER 400 000 BTU NG...

1 Answer

Green light comes on , can smell gas and hear buzzing from igniter but shuts down after 3 seconds and green light goes out


Make sure you have no soot build up on your ignitor. It will conduct elect so you can hear a buzz instead of a clear spark. Without a clean spark it wont fire and for safty it shuts down to keep gas from building up in the cabnit.

Sep 29, 2010 | Hayward 250kbtu Ng Pool Heater - Inground

1 Answer

Won't ignite


make sure wiring is correct for 220 vs 110 wired for 220 from factory if 110 see inside panel move wires ignitor is not getting hot enough

Jun 02, 2009 | Jandy LXI 400 NATURAL GAS POOL HEATER -

Not finding what you are looking for?
Pentair Mastertemp Heater Logo

Related Topics:

46 people viewed this question

Ask a Question

Usually answered in minutes!

Top Pentair Pool & Spa Experts

Pj Kiley
Pj Kiley

Level 1 Expert

21 Answers

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Pentair Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides