SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

ansari03
  • 2 Answers

SOURCE: NCR 7875 SCANNER/SCALE

Hello

Well regarding this error sending you this display of the scanner in most cases is needed because if the scanner calibration, you have to do is:

Remove the dish from scanner (where you put the products to weigh), there you will see that has a plastic part on the right side, and take away that the bottom is a black button color you need to start to put pressure gauge.
Once you press this button, and is ready to start calibrating, then put him back to the plate and the scanner with a voice that sends you will be asking some weight, so this should have on hand your weights to calibrate the scale.
First the scanner asks 0 kg. in this step not going to put anything in weight, ahi press the button Scale Zero appearing in the panel's scanner,
After asks you to 2.5 kg, is there when you need to put the 2.5 kg asks you, when you have them placed on the plate press Scale Zero, the scanner then will ask now that you put 5kg, then you take away those who had 2.5kg and you put the 5kg, and when you have 5kg in the dish press the button Scale Zero, now the scanner will ask that you put 10k, then take away the 5kg and that he had put the 10k that asks you to press the button and Scale Zero, and finally asks you to the scanner in this 0Kg, then you take away the 10k and leave it with nothing, and press Scale Zero

If the calibration did well Scanner you send a voice message that says Calibration Complet or calbración completed, it is very important that when you calibrating the scanner is not moving or having obstacles that may make the calibration is not made well, good clean plate and that this part of the bottom, which revises the 4 Gomito that has to sustain the plate are complete, that are not broken up or are some more than others and that when you put the dish did not move. fijate also not hit the plate or the chassis of the scanner with something else, so there's no obstacles in the calibration,
If you salio calibration is not well in the display will show a 9Error, this means that there was interference during calibration, it is required to check well before the scanner or do a cleanup.

Posted on Jun 30, 2008

blueextc3221
  • 15935 Answers

SOURCE: Tanita BD-590 calibration

Thanks for your question!
I'm sorry that you haven't received an answer yet.
The response rate on FixYa FREE questions is usually over 80%, but sometimes questions go un-answered when:
1. the question is unclear, incomplete, or poorly worded...
2. the question is mis-categorized - so the correct experts aren't viewing it...
3. the question requires an answer for something that cannot be explained online adequately...
4. specific training, tools, or equipment are required to avoid injury or death...
5. the Experts that are online simply don't have the resources to answer your question fully...
Please feel free to re-work your question if you feel one of these may be the reason.
Of course you are not required - but converting your question to a PAID one usually increases the reply rate as well.
Normal rates for FixYa are...
$ 9.99 answer for one question.
$12.99 Live Real-Time online chat or premium e-mail support.
$29.99 Live Real Time phone support
Sometimes FixYa will run specials for unlimited questions via monthly subscription or reduced rates for limited periods.


Consider the savings that can be had when an informed Expert can save you a $100 service call, or a $350 trip to the car dealership.
Your problem solved - guaranteed! Or your money back!!

If you don't want to pay - feel free to re-submit your question so it returns back to the top of the work queue if you still need help.

Thanks for using FixYa - a 4 THUMBS rating is appreciated for helping with your FREE question

Posted on Sep 05, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fix an EE error


That means that the scale cannot calibrate itself. When it turns on it checks the sensors to see if they are in range. It cannot find the sensors or they are out of range.

Nov 03, 2015 | Homedics SC380 Scale

1 Answer

How can you fix error on screen can it be reset


It often just needs recalibrating. Try turning the scale on while holding the mode/tare button with nothing on the scale. Then press the tare button again. It should show a calibration weight which you should put onto the scale. Then it automatically calibrates.

Nov 30, 2014 | DigiWeigh 100 X 0.01 Gram Digital Jewelry...

1 Answer

Ozeri ZK 14, error code oVE2, what does it mean?


oUt2 means that it needs to be calibrated. I am not familiar with these scales so no sure if they can be re-calibrated.

Jan 25, 2014 | Ozeri Pro II Digital Kitchen Scale in...

1 Answer

My shippng scale is not working and is giving me an error. I need to know what the error is


It needs calibration. Turn it on while holding done the mode button. The display will read CAL
Let the button go and put the weight on the scale it is asking for to calibrate
If the weight is to spec it will read PASS
Turn it off and back on to use
If it still shows error it make be damaged

Sep 05, 2012 | Royal EX330 Shipping Scale 29533D

1 Answer

Can i get the poll value required for Avery Berkel L225


To get the L225 to communicate, set up the baud rate, data bits, parity, comms mode (requested)handshake none. on the host ctrl e (ascii 05) is the request character used to query the scale.
The motion code is a token (ascii 173) that you include in the request string. for example {stx,nw,un,bcc,wst,etx} will of give u {start of text, net weight, units, block check character, weigher steady and end of text}

Walter --Applied Weighing Zim

May 17, 2012 | Computers & Internet

2 Answers

How to calibrate 1000xr us-magnum digital scale


magnum 1000xr pocket scales turns on calibrates goes to different modes but wont show the weight when object placed on the scale,a lock appears in top left of window, is scales broke or do i have to make lock symble dissappear?

May 28, 2011 | Kitchen Appliances - Others

1 Answer

Wont vacuum


With machine power OFF,remove old pressure transducer & replace new one.now power ON the machine & go for calibration.Calibration step for Robinair 34700Z machine.Form the main menu go to ''CHANGE DEFAULT'' then press 5454 & YES key (passwoed to access default option).Once you enter to default menu,go to "SCALE CALIBRATION" & press YES key.now follow the on screen help text.NOTE:you should have 9KG/20LBS of weight for scale calibration.
Hope this will solve you

May 21, 2010 | Robinair Cool Tech 34700Z Recovery,...

2 Answers

How to calibrate a taylor scale 5571


The following reset procedure is used when the scale shows an err2, err, 0.0, inaccurate weight,to calibrate, or some other unusual error.
  1. Remove the battery from the scale.
  2. Sit the scale on a hard surface floor.
  3. Step up onto the scale, stand still for about 5 seconds and step off the scale.
  4. Re-install your battery.
  5. Place the scale back on a hard surface floor.
  6. With one foot only, place just enough weight on the scale for the display shows zero’s or dashes. Once you see zeros or dashes remove your foot.
  7. Wait for the scale to turn off again.
  8. Step up onto the scale for a weight.
If the reset is successful, you should receive a weight right away. If you continue to receive one of the error messages above please call our Customer Service department.You can also try the reset procedure a 2nd time. Sometimes the reset procedure will work the second time.

Jun 13, 2009 | Taylor Body Fat Analyzer & Scale, Model...

4 Answers

Taylor 7530 scale wont turn on,i have new batteries


Basically, the frisbee comment is on the mark. I called Taylor. a nice person walked me through a calibration exercise: take batteries out; stand on scale for 7 sec.; get off; put batteries back in (assuming they are still good); step on scale and if it reads ---- step off again, then back on to weigh yourself. My scale's display was blank, not -----, so they said calibration was unsuccessful & so I mailed it back to the NM address on the bottom. It just fits w/ padding diagonally in a USPS flat rate box. Waiting to see if they replace it (lifetime warranty).

Dec 18, 2008 | Taylor 7532 Ultra Thin Glass Digital Scale

2 Answers

Error 5 for ncr 7875 scale scanner


Hello,
If the scanner read only two times is a problem with the communication protocol.

What protocol do you use?

Explain more about your problem with your calibration pricedure

Jul 29, 2008 | NCR 7875

Not finding what you are looking for?
Health & Beauty Logo

Related Topics:

86 people viewed this question

Ask a Question

Usually answered in minutes!

Top Health & Beauty Experts

Robin Hill
Robin Hill

Level 3 Expert

1263 Answers

wcdoc1953
wcdoc1953

Level 2 Expert

278 Answers

yadayada
yadayada

Level 3 Expert

75005 Answers

Are you a Health and Beauty Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...