Frigidaire FDL70S1 dehumidifier gives F2 error code

How do I fix this code problem?

Posted by Anonymous on

Ad

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017

Ad
  • 8404 Answers

SOURCE: My dehumidifier is giving me a F2 error message and isn't running

When I searched this error code, I found that F-2 means bad sensor. I found no further information as to what sensor it was. You don't give the name of the manufacturer, so I couldn't search from that perspective.

If it is a bad sensor, you may require professional repair.

Before I took it anywhere to be worked on, I would be certain that the catch bucket was setting square (indicating no water in the bucket).

Thanks for your interest in FixYa.com

Posted on Dec 26, 2009

Ad
  • 1 Answer

SOURCE: Frigidaire dehumidifier error code F2

Faulty tube sensor.

Posted on Apr 04, 2010

  • 79 Answers

SOURCE: Oil in my water reservoir for my Frigidaire FDL70S1 Dehumidifier

could be oil from a fan motor or compressor, either way thats not good

Posted on Apr 11, 2010

  • 3 Answers

SOURCE: Frigidaire Dehumidifier gives F2 error code and no longer runs.

F1 is room temperarure sensor error. F2 is tube temperature sensor error.

The room sensor usually is located in the front of the condenser. The tube sensor is usually plugged in a tube near the condensor.

The tube temperature sensor (thermistor) should be about 10K ohms.

Posted on Jan 12, 2013

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The F2 code is on in the humidity window of my Frigidaire dehumidifier? Not in manual. What does this mean?


Good Morning friend, thank you for your inquiry!
I see that you are having trouble with your Frigidaire dehumidifier displaying an error code of "F2". Typically, an "F2" error code stands for a miscommunication error. This could be a possible problem with a sensor or control panel. I would suggest performing a reset and that can be completed by disconnecting the power from your dehumidifier for roughly ten minutes. If you are still under warranty I would recommend contacting your manufacturer to see if any additional assistance can be provided. Hopefully this is helpful. -Matt

Feb 13, 2015 | Frigidaire Dehumidifiers

1 Answer

I have a FDL70S1 Frigidaire 70 pint dehumiifer that runs for 3 minutes then shuts off. I have tried to set the timer for it to run longer but it wont. Do you know what is wrong with it?


Hello lynn crisp, thank you for your post!

From what you have explained regarding your Frigidaire dehumidifier it sounds like the sensor or control panel has become faulty. I would recommend resetting your dehumidifier and you can do that by unplugging the power cord for ten minutes. Is your dehumidifier under warranty? If so, you may want to reach out to the manufacturer for a resolution to the problem. I hope this information is helpful. -Matt

Oct 20, 2014 | Frigidaire Dehumidifiers

1 Answer

I have a fdl70s1 and will only work in continuous mode.. Collects water fine but turns off when I adjust humidity setting


I appreciate your post, Lee Silvey!

I understand that your Frigidaire dehumidifier, FDL70S1, will only work in continuous mode. Sounds like you could have a possible issue with the sensor or control panel. Are you under warranty? I would advise you to speak with your manufacturer to see if any further resolution can be provided. -Matt

Oct 15, 2014 | Frigidaire 70-Pint Dehumidifier -...

1 Answer

Frigidaire dehumidifier has a F2 error and will not operate


Hello - Typically error code F2 indicates a sensor failed has occurred on the dehumidifier. You may want to contact your manufacturer to verify if the part is available and can be replace. Some do, some don't. Also confirm if the unit has a limited warranty on such concern.

Oct 20, 2012 | Whirlpool Dehumidifiers

1 Answer

I have a FDL70S1 Dehumidifier. Unit runs for just a couple minutes and shuts off-blinking bucket full even though no water in bucket. Unit won't stay on


Dont spend to much time trying to repair dehumidifier they are very cheap to replace. Most dehumidifiers have lots of problems because they are made so cheap. Just replace the dehumidifier you will tank me in the end.

May 17, 2011 | Frigidaire FDL50R1 Dehumidifier

1 Answer

I have a FDL70S1 dehumidifier that runs and runs but doesn't take out any moisture from the air. I have cleaned out the filter and front screens thoroughly but it still doesn't work. The unit...


Hi,
There are many reasons why a dehumidifier willnot work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrongwith their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101

May 10, 2011 | Frigidaire FDL50R1 Dehumidifier

2 Answers

How to fix f2 message? what is wrong?


If the display reads "F1" or "F2", a sensor has failed. Contact your Authorized Frigidaire Service Center.

Feb 21, 2011 | Frigidaire FDF50S Dehumidifier

1 Answer

Oil in my water reservoir for my Frigidaire FDL70S1 Dehumidifier


could be oil from a fan motor or compressor, either way thats not good

Apr 10, 2010 | Maytag M7DH45B2A Dehumidifier

2 Answers

Frigidaire Dehumidifier gives F2 error code and no longer runs.


F1 is room temperarure sensor error. F2 is tube temperature sensor error.

The room sensor usually is located in the front of the condenser. The tube sensor is usually plugged in a tube near the condensor.

The tube temperature sensor (thermistor) should be about 10K ohms.

Aug 31, 2009 | Frigidaire FDL45P1 Dehumidifier

Not finding what you are looking for?
Dehumidifiers Logo

Related Topics:

105 people viewed this question

Ask a Question

Usually answered in minutes!

Top Frigidaire Dehumidifiers Experts

Charles T Nevin
Charles T Nevin

Level 3 Expert

4070 Answers

Oloyede Monsuru

Level 3 Expert

1417 Answers

richie46

Level 3 Expert

12962 Answers

Are you a Frigidaire Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...