Expert
60 Answers
- Posted on Apr 15, 2013
Re: spc 220n has a sc400 code
Process Control Error
This SC is issued if the process control adjustment fails 5 times consecutively after AIO
replacement.
• Defective contact at the terminal between the machine and AIO.
• Dirty TM sensor
1. Check the contact of the terminal and re-install the AIO.
2. Clean the TM sensor.
×