1 Answer

I have Bryant HRV and the motor has failed. I have received a new motor but there are two extra wires on the replacement motor. Below I have described the wiring diagram from the original motor with the replacement motor following. My question is - do the two additional wires need to be connected? The VRV unit is a Model VB5AAB015 and the serial number is 0494V00006. This unit was instaled in my house in 1994. the original motor is a Fasco No 7190-0921 and the Type is U90B1 The connection diagram is as follows: White ------Line Black-------Line Brown----- - - Brown----- Green/yellow --ground The new motor is Model 71902271 and the type is U905B1 The connection diagram is different and this is where the two extra wires come in. On the control panel in the house there is no opportunity to change the speed of the unit. Connection Diagram Gray Common The gray and orange are together and have the same coupler as the white and black line on the old motor. Orange High Blue Medium Red Low Brown Brown Green/Yellow. So, do the blue and red wires need to be hooked up or can they just be secured? I don't believe my HRV motor has anything that these will attach to.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 144 Answers

Wire nut and tape the blue and red wires they are not used.

Posted on Mar 06, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Model 393 Bryant furnace fan or motor makes noise when first starting. Then it's quiet.


https://www.repairclinic.com/PartDetail/Bryant-Furnace-Dual-Run-Capacitor/P2914553RS/2386586?ss=a36b380&mr=0

That part is probably going bad. The motor uses it to get moving and when it fails then the motor wont start, makes buzzing or humming noise due to phase loss.

Jan 28, 2017 | Bryant Heating & Cooling

1 Answer

My blower fan doesn't come on.


2006 and later models have a X 13 blower motor. several million have failed. There is a 5 year parts warranty but you must pay for service to replace it. After the warranty expires a new one costs around $550.00 plus installation cost. Look on the end of the motor if it's an X13 there is no capacitor. If it's not an X13 the capacitor is the most likely problem.

Jul 13, 2014 | Bryant Heating & Cooling

1 Answer

Blower motor not working


2006 and later units have an X 13 GE non capacitor blower motor. Many many thousands have failed. There is a 5 year parts only warranty,if it has expired a new motor will cost $550.00 plus installation cost.

Jan 14, 2014 | Bryant Heating & Cooling

1 Answer

The 15 min timer doesn`t work anymore tried getting a new switch and still nothing. Any suggestion?


Fan or electrical wiring or power source are suspect.

Fantek RTS2 is supposed to boost HRV/ERV system into high speed for 15 minutes.
http://www.iaqsource.com/category.php/fantech-ervs-and-hrvs/?category=1494

If new RTS2 is not working, then either the wire to HRV/ERV system is suspect, unit is not getting power, or the HRV/ERV system is suspect.
If you are using RTS2 for ordinary ceiling fan, then install regular on-off switch and see it that works.
Check that you are getting power to switch and to fan. Check circuit breaker.

Jun 22, 2011 | Fantech RTS2 15-minute Pushbutton Timer w/...

1 Answer

I have an HRV system and want to know if it is possible to run a heat pump through my HRV ducts in the ceiling?


Hi, can you tell me what kind of heat recovery ventilation system you have? Is it a Honeywell, Lennox, ect.? Also tell me about how you have it set up as far as the duct work you are talking about and what kind of heat pump system you plan to install. If you tie your central air heat-pump ducts into the HRV ducts, it will interfer with the air flow. If you will, please tell me what you plan on doing as far as installing what to your home? New duct work for a new central air heat-pump unit, or what, so I will have some idea on what you are doing. Thanks so much. Contact me through my user name below.
Sincerely,
Shastalaker7

Apr 13, 2010 | Heating & Cooling

1 Answer

Bryant 557A fan blower not working. tech shows up and says need new fan motor. goes back to shop and owner of ac business calls and says he wants to recheck. comes back and puts test set on ...says new...


Is it burning up the motor or the control module?
If its the module the motor is probably running at full speed all the time. They need to check the wiring, duct static, filters, coil, any restrictions to airflow.
It might be a good idea to have them check with the Bryant customer service technicians or hot line. They deal with these problems all the time.

Dec 13, 2009 | Heating & Cooling

1 Answer

What is the part number for the outdoor fan motor?


as old as this unit is you probably cannot read the label on the motor it is either a 1/4 or 1/3 horse power 230 volt motor. a generic motor will work fine, use a 1/3 to be sure. also replace the capacitor so it matches the new motor. if you can read the label the part number is on it, should be an HK # with about 7 more digits

Aug 03, 2009 | Carrier Heating & Cooling

2 Answers

Is EDF5 required to have intermitant running of Fantech HR 2005R?


The SHR2005R will turn on the furnace Blower if the furnace is not running to circulate the fresh air. The reason the furnace will not trun on the HRV is, the purpose of the HRV is continuous Ventilation in your home. It should not be turned off when your furnace is not running. That why Fantech has not design the HRV's to run that way. I hope this helps.

Jan 18, 2009 | Fantech EDF5 Intellitek 5MR Control for...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

1,031 people viewed this question

Ask a Question

Usually answered in minutes!

Top Carrier Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Are you a Carrier Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...