Coleman powermate 2500 generator : engine runs good ... little to No power on recepticle ... vom reads 2. volts Motor runs, plug something in and it'll run for a few seconds and that's it. Took the cover off the bottom, 2 yellow wires from motor to the box, well the box has crack in it, don't know what it is but could it be a problem?

Posted by on

  • vrollins6704 Apr 06, 2009

    motor runs but no power in outlet

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 11 Answers

The generator Automatic voltage regulator ( AVR )already faulty. Try check it.

Posted on Mar 21, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

5 Answers

No AC out put


After working on several of this style coleman generator,i have found that the lead wires in the windings that are soldered to where your brushes would contact tend to break.I don't know if it's a poor design or just a fluke,i would check to see if your getting continuity on the rotor and go from there.They seem to either "burn off" or just break.

Mar 09, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

I have a coleman 5000 that won't hold voltage at 110 volts under load. It fluctuates up and down. The motor is running steady. What could be the cause of this?


govenor problem maybe does the engine sound slower when a load is on.
you will need something to read the power frequency

3000 rpm produces 50hz uk
3600 rpm produces 60hz

so if you have a meter to measure frequency you will also know what speed the engine is running at

Feb 27, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

How do you convert the (2) 240 volt outlets to one twist lock connector on a coleman powermate maxa 5000 er genset


Make an Umbilical recepticle adapter. Buy the recepticle install the recepticle in a 4" electrical BOX on a plate with two manufactured 3 prong power cords plugging into the 2 outlets and terminating at the new Box twist lock recepticle you made.

Feb 09, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

Have older powermate 5000 contractor gen. runs great but only puts out 5.5 to6.1 volts. has new brushes


Hello. Plug something into your generator's receptacle, say a trouble light. Then check the output. With no load at all [nothing plugged in, you will get a voltage reading that is low. regards, Joe

Jan 28, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

Powermate model 544000 generator undervoltage


There are basically 2 possibilities that can cause this.

1) Enigne RPMs are too low. but, since you already played with the throttle, this probably isn't the case. RPMs should be about 3600 though.

2) The voltage regulator / capacitor has high ESR (resistance) or is bad altogether. Replace.

Jan 01, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

My Generator is putting out voltage on both the neutral side and positive side of 110 Volt recepticles. When hooking a meter to both sides (Neutral & Positive) it is showing 184 volts! It burnt up a...


Check the voltage with a meter in all the recepticles with your meter leads in the left and right slots on the plugs. Is that 184 volts AC there? If so, your gen has big problems with the voltage regulator. Let me know what you read. You can check the right slot of each plug to the round ground hole on the plug too, should be 120 volts there.

Jul 01, 2009 | Coleman Powermate Proforce 6,000 Watt 12...

2 Answers

I have a Coleman Powermate Pulse 1750 generator. The engine runs fine but lately I've noticed I'm only getting approx. 105 volts. Any suggestions.


Engine speed is low, does your meter read frequency? Set for 60 Hz @ speed. I doubt there is a voltage regulator adjustment. This may help

Jun 25, 2009 | Coleman Powermate Premium Plus 6250W...

2 Answers

Coleman powermate 2500 generator : engine runs good ... little to No power on recepticle ... vom reads 2. volts


Sounds like you need to remagnitize your alternator, you can do this yourself but do it like this.
FIRST AND FORMOST STOP THE ENGINE AND WAIT TILL IT MAKES A COMPLETE STOP! AND LOCK OUT THE ENGINE SO IT WILL NOT ACCIDENTALLY START.
 pull the spakplug wire off the engine this WILL HELP ENSURE IT WILL NOT START. next take an old 120v power cord and cut the plug off with atleast 8 inches of wire on it. if it is a 2 prong wire or 3 it doesnt matter. grab your self 2  nine volt alkaline batteries, try just one battery first by plugging in the cord into a 120 volt receptical on your generator and make sure the circuit breaker is in the on position. MAKE DAM SURE THE GENERATOR IS NOT RUNNING BEFORE YOU DO THIS OTHERWISE YOU COULD BE ELECTROCUTED. it is quite safe as long as the generator is NOT RUNNING. put one lead on one terminal of the nine volt and the other lead on the other terminal and you will see a small spark if done right.MAKE SURE YOUR NOT DOWNWIND OF GASOLINE FUMES! if you have a 3 wire cord do not use the green ground lead use only the black and white or blue and brown. if its a two wire cord you cannot get it wrong. tap the wires on the battery terminals a few times. this shoud have remagnitised your rotor and stator. remove the cord from generator completely and put it away from kids and the incredibly stupid for safety. restart generator and plug in an appliance to see if it is making electricity. I recommend using a true rms digital voltmeter to check the voltage it should be between 110 and 130 vac rms for non regulated generator sets. if the 9 vold didnt do it you can use 2 nine volt batteries in series to flash the field. SAFETY FIRST ! ELECTRICITY CAN KILL, YOU DO THIS AT YOUR OWN RISK, I AM NOT LIABLE FOR ANYONES STUPIDIY. IF YOU ARE UNSURE HOW TO DO THIS THEN DO NOT DO IT! TAKE IT TO A QUALIFIED REPAIRMAN. LIFE IS IRREPLACIBLE SPEND A FEW BUCKS TO FIX.

Jan 16, 2009 | Coleman Powermate Proforce 2500 Generator

2 Answers

My powermate pm0647000 stopped generating electricity.


Flash it !
Start your generator, plug a single speed drill into the recepticle, while the generator is running make sure the drill is in the forward posistion then turn the drill chuck couterclockwise with your hand untill your generator power's up.
This simple fix " excites " the stator.
Good luck !

Sep 29, 2008 | Coleman Powermate Premium Plus 6250W...

Not finding what you are looking for?
Power Generators Logo

Related Topics:

284 people viewed this question

Ask a Question

Usually answered in minutes!

Top Power Generators Experts

John Trevino

Level 3 Expert

1378 Answers

Brad Brown

Level 3 Expert

13732 Answers

JOHN LAPIER

Level 3 Expert

2393 Answers

Are you a Power Generator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...