Aquastar 1600H NG Natural Gas Tankless Water Heater Bosch AquaStar Model 1600H NG Natural Gas Whole house tankless gas water heater, 117,000 Btu input, natural draft with hydro-generated ignition. Provides endless hot water for one major application at a time . Can replace 40-gallon storage tank water heater. Optional Accessory: Model AQ1- Power vent with built-in... More freeze protection when venting horizontally. Capacity: 1 to 2 Bathrooms Dimensions: 8.75D x 18.25 W x 29.75H Weight: 40 Max GPM @ 45F Rise: 4.2 Energy Factor: NG .80 LP .84 Minimum Input: 28,000 Maximum Input: 117,000 Vent Size: 5 Gas Connection: 3/4 Water Connections: 1/2 Warranty: 12-year warranty on heat exchanger, 2-year on parts Features: Endless hot water Can save up to 50% off utility costs annually Perfect for one major application at a time No standing pilot, hydro generated

Posted on Mar 20, 2009

2 Suggested Answers

  • 2976 Answers

SOURCE: takes a long time to heat water

If you are using a 3/8" copper line for your gas, get it replaced ASAP. It will fail. 1/2" Black Iron is required with natural gas. 50 gallons is a lot of water to heat. Look on the heater label for the recovery rate.

Posted on Feb 27, 2009

  • 5 Answers

SOURCE: RHEEM 40 GAL ELEC TALL Water Heater 6YR SC 82VH402: my rheem 81sv40d water heater quit heating water. ...

It sounds to me like the heater elements are shot or covered to thickly with calcium to function correctly

Posted on May 19, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why does it take two bowls of water before water gets hot on combi boiler


The water isn't maintained hot (unless the central heating is on) in a combi boiler. you will, therefore have to turn the water on, which activates the burner. The burner will then have to heat up the heat-exchanger which then supplies the hot water through cold pipes. Once the pipes are warm, you will receive hot water.

Jan 29, 2015 | Water Water Heaters

1 Answer

Can I put my central heating on a different time from my water horstmann didam 425


It appears there are 4 trippers on the daily time dial that control all timing. 2 On and 2 OFF

On the right side are override switches for Hot water and Heating
You can only separate Hot water and Heater programming a little bit.
You can choose to have Hot water ON all day, or turn on-off once per day or turn on-off twice a day. Or OFF all day.
The Heater has the same options and the same on-off times as the Hot water.

Manual:
http://www.horstmann.co.uk/files/2513/9867/2118/user_guide_425-TiaraDiadem1.pdf

For fully separate programming, where Hot water and Heater can each be programmed differently, you would need a 2-channel controller like the Grasslin QE2
http://www.grasslin-controls.co.uk/towerchronqe2.html

http://waterheatertimer.org/pdf/Grasslin-QE1-QE2_GB-instructions.pdf


Gene

Oct 11, 2014 | Water Heaters

1 Answer

Keystone manuals rv


You would need to buy a propane hot water heater. Unfortunately you can not convert an electric hot water hearter to propane.

I didn't want to use either an electric or gas hot water heater so I invested in a solar hot water heater for my home. Best thing that I ever did as far as saving money. Once it is paid off then the benefits are lower utility bills.

Good luck,

Marty

Jul 15, 2014 | Water Heaters

1 Answer

Water does not stay hot


Had this trouble with a condensing boiler,water pressure was too low, also if thereis an adjustable stat try turning this up ?

Jan 26, 2013 | Rinnai RU98i-N Interior Natural Gas...

1 Answer

I have an ariston 20/24 mffi combi pressure rises when switched to central heating but pressure ok when asking for hot water ? expansion vessel ?


over heat limit stat on central heating circuit ? if hot water is ok and hot to temp when run for 5 minutes the expansion vessel is doing its job.remember hot water is the maximum demand for any boiler ,,heating is secondry?once you establish hot water at maximum rate then the only real problem is on you demand for heating??

Dec 10, 2012 | Water Heaters

2 Answers

Water doesn't flow from the hot side. Was really cold last night. Is there a way to get it to flow?


Hi,
Yes... the water pipe is probably frozen... take a hair dryer and focus the heat on the piping...moving it back and forth along the piping to thaw it out...

heatman101

Feb 03, 2011 | Water Heaters

1 Answer

1992 Reliance electric water heater model 501 has two 4500 watt heating elements , there is no hot water.


Check the breaker and top thermostat and make sure they are not tripped. Move onto replacing elements if above is not the problem.
Turn water and power off to heater and attach a water hose to bottom of heater to drain down tank. May have to open hot side on a facuet to get it to drain.
Once drained remove elements with 1 1/2" found at local hardware stores. once elements removed and new ones in place. Turn water on and get the air out of the system. Once water is flowing from the hot side from all of facuet's in house.
Once all air is out now yaou are resady to turn power onto heater.

Oct 09, 2010 | RELIANCE ELECTRIC WATER HEATER

2 Answers

No hot water


in and out hooked up right?

May 17, 2009 | Eemax EX280T2T Series 3 Whole House...

3 Answers

Hot water problem


Someone has not sized the system correctly. The water heater will heat a certain GPM a certain temperature rise. Most of those "generalizations" from the manufacturers are referencing the lowest of all the flow requirements like 2 lavatories. The truth is, don't use other fixtures while showering or get a bigger system. Lots of information related to sizing the tankless system at http://www.mechanicalengineeronline.com/Mini_Sites/Tankless_Water_Heaters_Ebook/Tankless_Water_Heaters.htm Have a good one. PS:Properly sized On-Demand water heaters are actually really good. Be prepared for the day your water heater quits.

Mar 11, 2009 | Bosch & Tankless LP Hot Water Heater

Not finding what you are looking for?
Bosch 1600H-NG Natural Gas AquaStar AquaStar Natural Gas Tankless Water Heater... Logo

557 people viewed this question

Ask a Question

Usually answered in minutes!

Top Bosch Water Heaters Experts

Steven Foerst
Steven Foerst

Level 1 Expert

52 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21949 Answers

Raygin
Raygin

Level 2 Expert

322 Answers

Are you a Bosch Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...