Question about Xantrex Technology Trace Series Inverter / Charger 1500w

Open Question

I have a Iverter Trace DR 2424 Out of service, and i need the elecytronic diagram, o service manual. I would like to buy it. Thanks

Posted by on

  • Jerry Shannon May 11, 2010

    I can supply a manual it's 122 pages
    Repost if interested
    Thanks for using Fixya
    Jerry


  • Peter Mason May 13, 2012

    I would be much interested in that manual, could you please repost it?
    Thanks, Peter

×

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fault onroadpro 2500w inverter.The 110vac is going on100% but desapear imediately and hear only thefault noise


Did you ever find an answer to fix your problem?
I have the same type of problem, and feel bad as I am an electronics tech with years of experience. I know that it must be a bad IC, transistor, capacitor, diode, resistor, etc. However, with all the components in the 2500, it is almost impossible to trace it out without a "Service Manual" or a schematic diagram. To blindly go in to just start 'tracing' a circuit and not knowing the wiring is not good to do. It is also almost an impossible task to simply start removing parts to test on the bench, and then reinstall. Even IF all test good, there can be a fault on the board itself. For an answer you can do as I am doing, and that is to call the company that is listed as the company involved with customer service.

Customer support/contact, Truck and Automotive Accessories 1875 Zeager Road Elizabethtown, PA 17022 Sales & Customer Support Toll Free (866) 622-7979 support@das-roadpro.comwww.das-roadpro.com/roadpro

If you would need to hire a tech to find the problem he would have to be a good friend to volunteer his work or the cost would be as high as buying a pure sine wave inverter.

Take care, Dave. (DJnRF at yahoo)

Apr 11, 2014 | RoadPro Electronics - Others

1 Answer

I NEED A PARTS LIST AND DIAGRAM SO ICAN IDENTIFY PARTS NEEDED


Look on Boats.net. They have the exploded view of most Honda generators with the parts identified. They also sell the parts. They are a great resource and have been good to buy from. (I have no affiliation to them other than I sometimes buy parts from them)

Dec 31, 2013 | Honda Eu3000is Eu3000 Generator Service...

1 Answer

Where can I get PCB for my xantrex DR Series power inverter. PCB number is 39cx3yM. I'm in Tanzania.


Officially Xantrex has the position of Note: In order to protect our intellectual property, Xantrex does not release schematics, part lists or wiring diagrams to the public. Xantrex does not sell internal parts to the public. If you need an internal part replaced, your inverter will need to be serviced by an Authorized Service Center or at the Xantrex factory.

So your options are to ship it to an authorized Xantrex repair depot, or reapair it based on electrical knowledge in general

If you decide the latter approach, you have to see if there are any IC's or other semiconductors you can identify. If they are true sine wave inverters- the wave form genesis is what counts- you will have to locate the low frequency oscillator, if it will power up and you have an oscilliscope. you can see if the waveform genesis is a square wave originally, triangle wave or a sine wave. essentially move through the traces to see where the signal goes away. your failure point will be close.

If the original waveform is sine wave, applying class A, AB or B audio amplifier principles should allow you to effect repair.

If the original waveform was square wave or triangle wave- the wave form is shaped by an LC network. Depending on what sized Capacitors and inductors are inside of the cabinet will determine where the sinewave form was achieved. If they are physically small, the waveform was shaped off the Pulse Width modulation circuit, audio amplifier principles should apply in the circuit trace and troubleshooting with the scope.

if they are physically large- the waveform is shaped at the output device(s) Usually an IGBT or power darlington..

If you are working with a modified sine wave inverter, the principles and block diagram is similar to a Class D audio amplifier or a crude AM transmitter with none of the pass filters (oversimplification perhaps)

this ought to be either enough of a start or enough of an outline for you to determine how you want to proceed.

Dec 30, 2011 | Electronics - Others

1 Answer

I have a Xantrex 2400-12 two years old, installed off grid in a vacation home in Mexico, a service call is not an option. The inverter quit working, flashes "888" and shuts off. I have a trace...


First off I am not in this for the money. If your not satisfied with the information below simply reject the solution so that you can hear from other experts.

The 888 flashing is telling you that the inverter has lost DC power momentarily. This can be from broken strands in the battery cables or an internal wiring problem in the inverter. Check the battery cables for corrosion. Remove the terminals check for battery post corrosion and visually inspect each bable to terminal connection from the battery connector to the inverter DC Power connections.
Here is something to keep in mind. A DC power cable only needs one tiny strand of wire to indicate voltage on a meter. However, if there is any load on the AC side that tiny strand of wire that is giving you the proper DC reading may in fact drop well below 10.5 V DC and simply cause the unit to automatically shut off even with no load.

Explain your situation to Xantrex using the link below and they may be able to help you due to the fact that you do not have a local "post warranty service provider" in Mexico:

If your product requires troubleshooting or warranty service, contact your

dealer.

If you are unable to contact your dealer, or the dealer is unable to provide

service, contact Xantrex directly at:

Direct returns may be performed according to the Xantrex Return Material

Authorization Policy described in your product manual. For some products,

Xantrex maintains a network of regional Authorized Service Centers. Call

Xantrex or check our website to see if your product can be repaired at one of

these facilities.

What proof of purchase is required? In any warranty claim, dated proof of

purchase must accompany the product and the product must not have been

disassembled or modified without prior written authorization by Xantrex.

Proof of purchase may be in any one of the following forms:

• The dated purchase receipt from the original purchase of the product at

point of sale to the end user, or

• The dated dealer invoice or purchase receipt showing original equipment

manufacturer (OEM) status, or

• The dated invoice or purchase receipt showing the product exchanged

under warranty

Telephone: 1 360-925-5097

Fax: 1 360-925-5143
Web: www.xantrex.com/support
customerservice@xantrex.com

The owner's guide is here:
http://www.xantrex.com/documents/Power-Inverters/Xantrex-Inverters-Digital/XPower_200-400-800_Digital(975-0176-01-01_Rev-B).pdf

Thanks for choosing FixYa,
Kelly

Jan 16, 2011 | Xantrex Technology Trace Series Inverter /...

1 Answer

How to connect the inverterto acmains?


Hi,
Battery to invertor should be quiet clear. Attach the positive then the negative lead.

There needs to be a special socket in the wall. Buy a normal three pin socket. Go to the mains. Take the line coming in and connect it to the L ('Live') marked pin. It is left one. Now take the other pin and trace it back to where electricity was originally going. What you have done is basically placed a socket in the line. See diag below:
1f4b4dd.png

Now take a plug. see diag and connect so that it has live going into the invertor and invertor supply coming out.
18e08e7.png

So basically you have looped the supply thru the invertor.
Be sure to read the manual. Certain invertors may have other wiring.

Electricians are cheap. Get one. It will be worth it, in case you are unsure.

Cheers
TeaCii
LiveOnline

Apr 22, 2010 | Inverter 500 - 1000 Watt DC to AC - Safe...

2 Answers

I have a trace inverter DR 1512, I am having a problem with my system, which includes a 5000 watt gen, and solar power. When I am dry docked and have solar, system functions fine, when I lose solar and go...


the solar panel is just to charge your inverter,if it is charging and the inverter is on it will drain the current the solar panel is supplying to the batteries,this makes it look like it is not charging ,so i advice you to switch off you inverter when charging it,get another set of batteries connected to your solar panel then charge both, let them be separated so that the new one is not in use so that when solar is out you can switch to the other set of batteries

Nov 25, 2009 | Xantrex Technology Trace Series Inverter /...

1 Answer

My tram 2512 is stuck in waiting for AC mode, ac is clearly reaching the unit, both by shore power and genset. What could the problem be?


If you are referring to a Trace 2412 inverter, which series is it? An SW or a DR series? In either case, if it won't accept generator power, but the AC input indicator is flashing, the problem is most likely the generator output power is off frequency or voltage. Trace inverters will only connect when the AC input is within certain limits. I'd suggest checking the frequency and voltage output of the generator. If it won't connect to shore power, check the voltage from that source. Make the voltage checks at the inverter input terminals.

May 11, 2009 | Xantrex Technology Trace Series Inverter /...

2 Answers

Trace DR 2412 inverter won't run older front-loading washer


IF your washing machine is a conventional model with a common AC induction motor, waveform isn't the problem. Normal starting current for typical AC induction motors is usually 5 to 7 times the rated running current. Even though that current draw only lasts a fraction of a second, it's marginal for a 2.4 kw inverter's surge capacity. The trick of switching on other small loads (preferably resistive loads like incandescent bulbs) before starting the washer may help. Another area to check is your battery cables and connections The inverter pulls a huge amount of current to produce it's max surge output and even a little resistance in the battery circuit may cause the inverter to trip off. If you've got one of the fancy new electronic controlled washers with a D.C. motor, (so called energy saving or high efficiency models) then the waveform may be an issue and a pure sine wave might be needed.

Apr 01, 2009 | Xantrex Technology Trace Series Inverter /...

1 Answer

Trace inverter high AC voltage


Not to worry. First thing is you are probably not using a true RMS volt meter. You are reading an average voltage of peak. You have a sine wave inverter. The RV 2012 has a peak of 164 volts. I could go into much more tech detail but may confuse you. If you want to learn more her is a link from my dealer tech sheets. Also if you have checked voltage in a float state it will read high.
Hope this helps you
Thank you for using Fixya and please rate us.
Jerry

http://www.xantrex.com/web/id/325/DocServe.aspx

Mar 24, 2009 | Xantrex Technology Trace Series Inverter /...

Not finding what you are looking for?
Xantrex Technology Trace Series Inverter / Charger 1500w Logo

Related Topics:

599 people viewed this question

Ask a Question

Usually answered in minutes!

Top Xantrex Technology Electronics - Others Experts

Brad Brown

Level 3 Expert

13805 Answers

EE Eddie

Level 2 Expert

99 Answers

Jay Plesset

Level 3 Expert

2815 Answers

Are you a Xantrex Technology Electronics - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...