My desa vent free propane heater's pilot light starts fine but when the thermostat kicks in it looks like the pilot flame gets sucked up into the heating flame. Once the heater shuts of the pilot light is out. Very frustrating in the greenhouse. Any idea? Thanks

Posted by on

  • musommers Feb 18, 2009

    I will try that, even though the heater is basically brand new, purchased in October. Can it get dirty that quickly? Thank you!

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 51 Answers

I would turn your has off. Then take apart your pilot gas line, and clean out where the gas come out. There is a very small hole there that will get dirty.

Posted on Feb 17, 2009

  • Kent Guidry
    Kent Guidry Feb 18, 2009

    No it should not get dirty that fast. I was unaware that the unit was new.

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The pilot light goes out when I turn the gas control know to on


Clean the flame sensor, thermocouple, or power pile located on the pilot with steel wool.

Nov 23, 2013 | Rinnai Desa Vent-Free Infrared Gas Heater:...

2 Answers

Pilot won't stay lit on mr heater vent-free propane heater


if it is direct vent chances are it has electronic pilot.. it does not have a standing pilo and match size upt. if in fact it did have a buning pilot there is a part called thermocoupling. it will look like a 1/8 in. copper wire coming out of the bottom of the gas valve and goes right to the pilot. anywhere from 10 in. to 20in.. unscreew nut at gas valve pull out from pilot area [ it just clips in at pilot] take it to any home center

Nov 25, 2012 | Kitchen Ranges

1 Answer

My husband and I recently purchased a house that has a Comfort Glow Vent-free Propane/LP gas compact fireplace 14,000 to 26,000 BTU/Hr with Thermostat. Model CGCFTP We need to light the pilot light and it...


Remove the small copper colores tubing going from the gas valve to the pilot assembly. Take it to a good hardware store that sells heaters and ask them for a new one.It is called a thermocouple.

Nov 18, 2009 | Desa International Heating & Cooling

1 Answer

I cant get the logs to light only the pilot light


Can you smell gas when the pilot goes out? If so, you may have too much pressure. If you just changed bottles and didn't do anything else, look at the flame sensor. It may be the problem. Good luck...Lee

Nov 12, 2009 | Blue Flame Charmglow 30K BTU Propane Vent...

1 Answer

Have Model CGP30TB Copmfort Glow propane heater. Pilot light won't stay lit. Flames also coming from what seem to be air vents just below flame on pilot light.


sounds like an obstruction in pilot assembly.try using canned compressed air to blow directly into pilot. this technique is successful about 70%. if not,pilot assembly must be removed and cleaned thorougly

Sep 10, 2009 | Desa International Comfort Glow Infrared...

1 Answer

My vent free Desa natural log will run for a short


it is likely you have dirty O2sensor, it is incorporated into pilot assembly.turn unit off,use compressed air in a can and blow into spot where pilot flames comes from.this will fix it in most cases.in a small % of time entire pilot assembly needs to be taken apart and cleaned

Jun 25, 2009 | Desa International Unvented Gas Space...

1 Answer

Wont run


check the flame detector it may be a millivolt generator or a flame rod feeding to an electronic circuit.

Nov 16, 2007 | Rinnai Desa Vent-Free Infrared Gas Heater:...

Not finding what you are looking for?
Ace Hardware ML250TPA Infra-Red Wall Mounted Panel Heater Logo

279 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ace Hardware Heating & Cooling Experts

paulcarew

Level 3 Expert

2364 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you an Ace Hardware Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...