Have a 5 10 15 30 leviton timer to bath fan. switch is now buzzing though had been fine. what's going on.

The Leviton LTB30 20 amp timer has a known design flaw. It has a 1 microfarad electrolytic capacitor installed against a screaming hot resistor. Cooks and dries out the cap even when not in use. 50% failure rate in my initial install of 4 units.
Pull it apart and replace the electrolytic with a ceramic cap and it will be fine. I have two of many that have already failed.
Poor design of voltage regulation and poor layout of cheap components that self destruct. Design is not half baked, it is fully baked, lol.
Can be fixed though, so not all bad...
0helpful
1answer

Leviton dimmer

Your product is not identified by number given.
Leviton posts manuals online by searching Leviton xxxx .pdf.
There is a CPT 602 lighting console
However no result shows online or at Leviton for a 602 dimmer
Contact Leviton:
http://www.leviton.com/OA_HTML/SectionDisplay.jsp?section=37579&minisite=10251
Add a comment and attach photo or video for possible identification

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Where can a get information how to install a automatically turn light swicht leviton model occupancy sensor m,odel

What's the problem? You can get instructions at leviton website but also suggest you read competing products manuals to build perspective. These are difficult to install in 3 way wiring situations. In 3-way they only seem to work well when wired to load not line side. In 3 way I suggest you wire in 2. There is a certain way of doing this. I just looked at instructions for Leviton's competition.
0helpful
1answer

I installed the PR180 switch in my garage with a 4ft dual t-8 flourescents bulbs. When the motion sensor timer turns the light off the flourescent bulbs stay slightly lit, as if it were on a dimmer...

There is nothing wrong with the switch or your wiring. The Leviton R01-PR180-1LI is not designed to work with flourescent lights. A lot of electronic controls will bleed through a small voltage when in the "OFF" state. It's just enough voltage to make the ballast in the flourescent light try to fire but not enough to let it fire the way it is supposed too.

What you need is a motion switch that is rated for flourescent lights, such as this :-( :
http://www.smarthome.com/2520W/Leviton-ODS10-IDW-Commercial-Grade-Wall-Mounted-Occupancy-Sensor-White/p.aspx
0helpful
1answer

I installed the motion sensor on a 3way switch. Connected the red lead to the common and the yellow w/red strip lead to a traveler and the black lead to the other traveler. No matter how i switch the...

Leviton manuals:
http://www.leviton.com/OA_HTML/ibeCCtpSctDspRte.jsp?section=17219&minisite=10022

A quick peek inside a sample Leviton manual confirms that your wires are connect correct - BUT...
http://waterheatertimer.org/pdf/Leviton-motion-Instructions.pdf

The remaining 3-way switch needs a jumper wire.
See if your instruction manual shows the same thing as image below.
Let's go through this.
The yellow wire connects to a traveler ... and that traveler connects to one of the brass screws on 3-way switch.
The black wire from Motion sensor also connects to a traveler wire ... BUT you have to identify which traveler wire and which brass screw that traveler wire connects to. And then, put a jumper wire (a short piece of wire) from that brass screw to the dark-colored screw.
I think that will do it.
Add a comment if your device is different.
geno_3245_100.jpg

Some of these electronic devices are reversed when two of their wires are connected together.
That's what the jumper wire is doing. So the 3-way switch is just connecting and disconnecting the black and yellow wires, and that action reverses the circuit in the motion device.
0helpful
1answer

I have installed (or tried to) three different Leviton PR 180s in my front hall. All operated the 23 watt fluorescent bulb in the fixture satisfactorily, but were not affected by the ambient light; that...

The Leviton PR180 is a motion detector, or occupancy detector.
It senses infrared heat from a person's body.

I am looking at the manual from Leviton.

Maybe this will help:
There is a small adjustment screw under the wallplate where you can adjust light sensitivity.
Use fingernail or small screwdriver.
Turn control towards the "-" sign and lights will turn on in 'less lighting conditions'

I will be here for a few more hours.
Add a comment and I will help further is needed
1helpful
1answer
0helpful
1answer

Leviton wireless switch fails to work all the time

50 feet is the maximum range for the switch, per manufacturers spec. Range is diminished somewhat for walls, doors, etc.

IIRC, there is a plug in transceiver available from Leviton, however, if the price of the booster for the main panel is included in the $100 installation, then I'd say that's a fair price. You may try to keep fresh batteries in the switch.
Not finding what you are looking for?

82 views

Ask a Question

Usually answered in minutes!

Top Leviton Hardware & Accessories Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66847 Answers

Steve Pack
Steve Pack

Level 3 Expert

7126 Answers

Are you a Leviton Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...