Question about Sears Craftsman LiftMaster Chamberlain Garage Door Opener Wireless Keypad Model 976LM Security+

1 Answer

No eletrical power in unit after touched red and white terminal

Hello....I have an liftmaster model 1046. and i was just about to replace the gear inside but i was testing the motor to make sure by touching the red and white screws with a screw driver and and i guess i left it on too long and the 4th of july happen in front of my eyes... what did i do..??? now i have no electrical power in unit at all.. Is it a goner..???? Is their a fuse i can replace or do i have to replace the whole unit..??? Or is their a main cirucit board i can just replace... I replaced the gear inside before. but now i think i have a bigger problem now.. uh-oh... please help... thanks ^ - ^

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Sergeant:

    An expert that hasĀ over 500 points.

    Champion:

    An expert who has answered 200 questions.

  • Expert
  • 373 Answers

In my opinion I wolud get another one

Posted on Feb 06, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Wiring for model Number 139-53663srt2


White wire with red tracer from wall control goes to terminal #1.
Solid white wire from wall control and each door sensor go to terminal #2.
White wires with black tracer from door sensors go to terminal #3.


Oct 19, 2010 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Craftsman LiftMaster Chamberlain Garage Door Opener Wireless Keypad Model 976LM Security+: i'm reinstalling my garage door opener because the...


Terminal #1 - White wire with red tracer from wall control

Terminal #2 - Three solid white wires. One from wall control and one from each of the door sensors.

Terminal #3 - Two white wires with black tracer from the door sensors.

May 17, 2010 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Installing 41A5483-2b need wiring instructions


White wire with red trace to terminal #1. Three solid white wires to terminal #2 and two white wires with black trace to terminal #3.

Mar 27, 2010 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Trying find where the wired for button and sensors go on liftmaster door opener


The wire with the red stripe goes to terminal #1. There are 3 solid white wires that go to terminal #2 and the 2 wires with the black stripe go to terminal #3.

Nov 18, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

I need to no the right wiring way on the back of th eopener


White wire with red tracer goes to terminal #1. Three solid white wires go to terminal #2. Two white wires with black tracer go to terminal #3.

Oct 25, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

How do i conect the low volt wire ( the safty eye and the button wire)?


The terminals on the rear of the motor unit are both numbered and color coded. The white wire with the red stripe from the wall control goes to terminal 1. The solid white wire goes to terminal 2. The 2 white wires with the black stripe from the sensors go to terminal 3 and the 2 solid white wires go to terminal 2. You should end up with 1 wire on terminal 1, 3 wires on terminal 2 and 2 wires on terminal 3.

Sep 23, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Re: 1/2 hp liftmaster Just installed new circuit board Neither sensor light works and the power sources at the board are not hot If I put the meter on the # 1 terminal and either #1 or #2 I get 34...


Are you sure you connected the wiring to the new board correctly? Terminal #1 should have a white wire with red tracer. Terminal #2 should have 3 solid white wires and terminal #3 should have 2 white wires with black tracer.

Does the opener do anything at all?


Jun 28, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Wall mount not opening door. Looks like its not getting power.


You may have disturbed the wiring leading to the wall control. It connects to terminals 1 and 2 on the rear of the motor unit. The wires are color coded and must be connected correctly. The solid white wire goes to terminal 2 and the white wire with red tracing goes to terminal 1.

Jun 13, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Liftmaster 1/3 HP opener won't close


strange, was going to say eyes not aligned but you say they are. try over-riding by holding down wall pushbutton or jumping from red and white terminals. Did you increase down force. Are limit switch terminals moving, If it hits one, it should go back to other,

Feb 12, 2009 | Sears Craftsman LiftMaster Chamberlain...

1 Answer

Garage door opener unresponsive.


You need to reset the limit settings. There are three white screws on the bottom of the opener with the cover off. You will need to take the bottom off the gear and sprocket assembly. Turn the middle screw to where the wings are most of the way up and move the trolley to the up position. Put the bottom of the gear and sprocket back on and adjust the two other screws ti make door open and close completely

Jan 24, 2009 | Sears Craftsman LiftMaster Chamberlain...

Not finding what you are looking for?
Sears Craftsman LiftMaster Chamberlain Garage Door Opener Wireless Keypad Model 976LM Security+ Logo

54 people viewed this question

Ask a Question

Usually answered in minutes!