Question about Heating & Cooling

1 Answer

Euro Pro Steamer Model No : SC507H

When plugged in, led light doesn't turn on and doesn't heat up. Anyone know the common failure in the system? Remedy? Thanks

Posted by on

  • Anonymous Mar 17, 2009

    The light does not come on and it doesn't heat up !

  • VBtoons
    VBtoons Mar 18, 2009

    It seems internal, I wished there was a universal part that could replace the "overheat cut out" unit your mentioning. I don't even have enough info or schematics to understand how it works.

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 3 Answers

Sounds like ther is an overheat cut out that has tripped. it may be extrernal and need pressing to reset or may be internal and need relacing.

Posted on Feb 06, 2009

  • gazt23 Feb 06, 2009

    sounds like ther is an overheat cut out that has tripped. it may be extrernal and need pressing to reset or may be internal and need relacing.

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My Xenon high efficiency furnace has a red blinking led light that blinks 4 times and my furnace will not light. What could be the problem?


Gas furnace fault or error codes for common furnaces - Gray ...

www.grayfurnaceman.com/-ifc-failure-codes.html
Each color will also flash a specific number of times to signify a specific error. ... 4 redcolored flashes may be signaling that the "high-limit" switch might be open. ... 3 green colored flashes on your furnace has the same meaning as 2 green colored flashes. ....If a system problem occurs, a blinking LED shows a fault code.Missing: xenon

7 Tips and Tricks to repair your Furnace DIY - YouTube

? 13:25
https://www.youtube.com/watch?v=rAtcvPqUsBA
Dec 18, 2012 - Uploaded by JRESHOW .
Flash sequence codes 1 through 11 are as follows: LED will turn "on" ... 4 RED FLASHES: This indicates that the main limit switchhas opened ... This no-light condition occurred 3 times (2 retries) during .... My furnace trane xe80 is only flashing once my manual says something about flame being locked out ...Missing: xenon ‎efficiency

Nov 21, 2015 | Heating & Cooling

1 Answer

I have a Coleman Furnace Model G8T10016U4B11A, the red light flashes twice and I get no combustion blower. Can anyone suggest a solution? Is it a bad board?


Your combustion motor is the very first thing to cycle when theres a call for heat. Look at your access panel. There should be a LED status indicator chart. It will tell you what the flashing LED means and what your most likely problem is.

Mar 12, 2011 | Coleman Propane Forced Air Heater...

2 Answers

Hi i have a dyno glo pro heater model number RMC-KFA170TDGP it worked great last year this year its been nothing but a pain flames shoot out the front by times sounds like its getting to much air but the...


did you try cleaning the lens of the photocell, they git dirty from smoke ver time which regulates the flame or replace the nozzle, sounds like it could be getting plugged up? usually any heating store would have a nozzle for a couple bucks if you get the number off it. the nozzle is right where it comes out and they are common to plug up at times with wear

Jan 18, 2011 | All-Pro Kerosene Garage Shop Heaters - All...

1 Answer

PGB030075-1 Led light is blinking 4 quick blinks. blows out cold air. What does this mean?


4 blinks indicates a failure at the high limit switch. This switch is usually located on the heat exchanger face plate and has two wires going to it. Usually it fails because the furnace has over heated. The most common reasons are a plugged filter or coil that is limiting the airflow over the heat exchanger. Turn off the power to the furnace, replace the filter, clean any coils in the plenum and verify that all the vents in the home are open. Then turn the power back on and see if it is fixed. :)
If the above solution does not fix the problem, the limit switch itself may be bad from excessive heat. Replace it with a new one. Good Luck!

Dec 28, 2010 | Goodman GMS90703BXA Heater

1 Answer

My pro 100 does not light. Igniter heats up and


The photo eye shuts the unit down if the burner does not burn correctly on startup, ie.if the eye does not see light prior to tiiming out. I would say since it is shutting down, it is working OK. While you say there is plenty of fuel, you do not know if there is the correct ratio of air to fuel. The most common problem on these heaters is the mix. I have a tip at http://www.fixya.com/support/r4124129-yearly_maintenance_reddy_heaters which explains exactly what you need to do to correct this and where to get the parts to do it. Let me know if you need anymore help.

hardrocko

Thanks for using FixYa

Mar 01, 2010 | Desa International Reddy Heater® RHER70CT

1 Answer

Armstrong upflow,unit works intermittent problem,call for heat nothing happens,error code of 5 blinks then 6 blinks. i have no manuel, and the panels dont have the codes on them. anyone have access to the...


Armstrong

FAILURE CODES

LED Status Fault Description
Off
No Power to the System Control

Steady Flash (11 or more flashes with no pause)
Normal Operation (Standby or call for heat)

2 Flashes
Pressure Switch Closed When It Should Be Open

3 Flashes
Pressure Switch Stuck Open 30 Seconds or Longer After Call for Heat (System in 5-minute delay mode before next call for heat). On/off switch in "off" position during a call for heat will generate this code.

4 Flashes
Open Limit Switch or Limit Switch Circuit

5 Flashes
Flame Sense Signal Sensed Out of Proper Sequence

6 Flashes - pause - 1 Flash (see Note 1)*
Soft Lockout Type 1 (Failure to light within 4 trials for ignition)

6 Flashes - pause - 2 Flashes (see Notes 1 & 2)*
Soft Lockout Type 2 (Flame sense lost during run)

6 Flashes - pause - 3 Flashes (see Notes 1 & 2)*
Soft Lockout Type 3 (Pressure switch opened during run)

6 Flashes - pause - 4 Flashes (see Notes 1 & 2)*
Soft Lockout Type 4 (Limit or limit circuit opened during run)

6 Flashes - pause - 5 Flashes (see Note 1)*
Soft Lockout Type 5 (Flame has gone away after Error Code 5)

6 Flashes - pause - 7 Flashes (see Note 1)*
Soft Lockout Type 7 (Self-check failure)

10 Flashes* - SV9520H8034 only
Line Input Voltage Polarity Reversed

Dec 12, 2009 | Coleman Heating & Cooling

3 Answers

Reddy Heater will not ignite flame


Please answer the following questions. There are several folks on the board that can help but we need to know some vital information so we can get started. Answer these, if you can:
  1. Which Pro 110 do you have. We need the exact model number. Pro 110 is a series of heaters.
  2. Does the heater have a spark plug or a glowbar (HSI)?
  3. When the motor runs is it pumping fuel?
  4. When the motor runs is the spark plug firing (or glowbar glowing)?

Nov 13, 2008 | Reddy Heater-170,000 BTU Kerosene Deluxe

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

169 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2059 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Cris Sparks
Cris Sparks

Level 2 Expert

338 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides