Question about Power Center Jumpstart 11-411

2 Answers

Lost manual, how do I read LED indicating lights

11/414 Motor Trend Power Center Jumpstart(TM) with air compressor. Has 3 LED indicators in a line across the front of the jump starter. Red, Yellow, Green. How do I know when the unit is fully charged? How do I use it to read battery condition?
Do I try to start car right away or let it sit connected to the jump starter for a few minutes?
How can I get another operating manual?
Thanks!

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer
  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Sergeant:

    An expert that has over 500 points.

  • Expert
  • 406 Answers

The lights across the jumper are to show charging condition of the internal battery when you push the test button a full charged battery will light them all up with a bright GREEN on the end..as far as using it..use it as soon as you attach it..this way all the reserve power is available instantly good luck

Posted on Sep 29, 2014

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Why does my new motor trend power house jump starter with air compressor not take a charge from the a.c. or d.c. charger?


Contact manufacturer. If still under warranty they should replace. Sounds like the internal battery is dead...there has to be a little "juice" left in the battery for the charger to have a complete circuit to charge...some of these units take 24 or more hours on an initial charge.
Hope this helps,Ron

Nov 30, 2014 | Power Center Jumpstart 11-411

1 Answer

How do you recharge a Motor Trend Jump starter and air compressor


Should have been a patch cord that connects directly to the unit and to 110 volt plug for charging the unit back up. There's a built in convertor that does the re-charge. Find that cord or purchase one from where you got the unit.

Jun 28, 2014 | Power Center Jumpstart 11-411

1 Answer

I bought at a garage sale a Motor Trend air comressor jump start battery for emergencies with my car, but need the 0wners manual, any suggestions?


take the air compressor battery jump start device to any auto parts stores that sales the same device they will give you idea and show you how it works.

Oct 07, 2011 | Power Center Jumpstart 11-411

1 Answer

My little brothers put a needle on the air compressor to pump up balls and now i have no idea how to get it off to pump up my bike.. help?


is it a lever or is it a screw on end on your compressor? if it is a lever just release it by pulling it up and remove the needle' if it is screwd use 2 pair of pliers

Jul 13, 2010 | Power Center Jumpstart 11-411

1 Answer

Tv desn't turn on,power light just flashes ten times and then stops and then again


Error Indication Information
Error No. Error Information ERROR DESCRIPTION LAMP LED OSD LAMP OFF
(Note 3) (Note 4)
POWER LED TEMP LED
Note:
1.When any of the above errors has occurred, the LED will flash as shown above every 5 seconds.
2.When two or more errors have occurred at the same time, the LED will light up or flash as shown above, and then
change to another every 5 seconds in turn.
3.Warning OSD appears when the Air Filter is clogged 90%, accumulated operation time of the Lamp reaches 5000 hours,
or accumulated operation time of the Air Filter reaches 400 hours.
4.LAMP OFF: The LED will flash right after the Lamp goes off.
5.IC2301 is mounted on LCD Main C.B.A. which is included in the Projection Unit.
6.IC6001 is mounted on TV Main C.B.A.
Clogged air filter
more than 90%
15)
16)
17)
18)
1)
2)
3)
4)
5)
6)
7)
11)
8)
9)
10)
12)
13)
14)
- flashes 5 times -
every 5 seconds
IC2301(pin82) detects the clogged air filter, then indicates the
error when the air filter is clogged 90%.
Front Fan stop or
Lamp Fan stop
flashes orange
once every
5 seconds
- -
IC2301(pin12) detects the Front FAN stop or Lamp
FAN stop, then indicates the error when the Front FAN
or Lamp FAN is stopped.
Lamp Cover open
Temperature Sensor
short or open
flashes orange
twice every
5 seconds
flashes orange
3 times every
5 seconds
flashes green for
140 seconds.
flashing red for
60 seconds.
light up red.
flashes once
every 5 seconds
flashes once
every 5 seconds
flashes red for
10 minutes
flashes once
every 5 seconds
-
-
-
-
Abnormal
Temperature
flashes twice
every 5 seconds
flashes twice
every 5 seconds
- -
Request for Lamp
Replacement - - lights up
Power Ballast Error
(abnormal
Lamp voltage)
- -
flashes 3 times
every 5 seconds
Power Ballast Error
(abnormal
temperature)
- -
flashes 4 times
every 5 seconds
Power Ballast Error
(other causes) - -
- -
Request for Filter
Cleaning -
Abnormal Voltage
on 16 V line of
LCD Main C.B.A.
-
flashes twice
every 5 seconds
flashes twice
every 5 seconds
Abnormal Voltage
on 14 V line of
LCD Main C.B.A.
-
flashes 3 times
every 5 seconds
flashes 3 times
every 5 seconds
Abnormal Voltage
on 7 V line of
LCD Main C.B.A.
-
flashes 4 times
every 5 seconds
flashes 4 times
every 5 seconds
IC2301(pin76) detects the Lamp Cover Unit condition
(open or close), then indicates the error when the
Lamp Cover Unit is open.
IC6001(pin85) detects the Duct FAN stop, then
indicates the error when the Duct FAN is stopped.
IC2301(pin74 and 75) detects open or short of the Temperature
Sensor (R2911) on Front Thermistor C.B.A., then indicates the
error when Temperature Sensor is open or shorted.
(The error is not detected for 1 minute after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Front FAN by the Temperature Sensor (R2911) on Front
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 43 C (109 F).
(The error is not detected for 1 minute after Lamp ON.)
IC6001(pin86 and 87) detects open or short of the
Temperature Sensor (R2901) on Lamp Thermistor C.B.A.,
then indicates the error when Temperature Sensor is open or
shorted.
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Lamp by the Temperature Sensor (R2901) on Lamp
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 60 C (140 F).
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin11) detects the error of LCD Power C.B.A.,
then indicates the error when the temperature fuse
(117 C)(243 F) in LCD Power C.B.A. is open.
IC2301(pin11) detects the error of LCD Power C.B.A. and Lamp,
then indicates the error when an inner malfunction of LCD Power
C.B.A. occurs, the Lamp voltage becomes more than 130V or
less than 30V, Lamp current becomes more than 5A, or the Lamp
is cracked.
IC2301(pin11) detects the error of the Lamp, then indicates the
error when the Lamp is short-circuit.
IC2301(pin48) detects +16V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +13V.
IC2301(pin47) detects +14V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +11V.
IC2301(pin45) detects +7V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +5.7V.
IC2301(pin44) detects +3.3V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +2.5V.
flashes 3 times
every 5 seconds
flashes 4 times
every 5 seconds
Abnormal Voltage
on 3.3 V line of
LCD Main C.B.A.
-
-
-
- flashes 5 times
every 5 seconds
Forced cooling
The failure of Lamp
light up
-
Temperature Sensor
short or open
-
-
Abnormal
Temperature
Duct Fan stop -
When accumulated operation time of the the Lamp reaches
5000 hours, OSD (replacing the Lamp) appears on the screen.
Note: The Lamp time is stored in EEPROM (IC2305).
When accumulated operation time of the Air Filter reaches 400
hours, OSD (cleaning the Air Filter) appears on the screen.
Note: The Filter time is stored in EEPROM (IC2305).
During forced cooling, this indication is indicated.
IC2301 (pin11) detects the failure of light up processing of
the Lamp, then the POWER LED is changed as follows.
1) POWER LED flashes green for 140 seconds (while turning on).
2) POWER LED flashes red for 60 seconds (while cooling).
3) POWER LED lights up red (standby).
Note: If the Lamp will not light after attempting turning on the
power 2 or 3 times, the Lamp, the LCD Power C.B.A. or the
LCD Main C.B.A. may be defective.
Error Symptom Problem Possible Solutio

May 30, 2010 | Panasonic Viera TH-50PX80U Plasma TV

1 Answer

I need to buy a power cord for the 11-410 Jumpstart w/ Compressor. How/where do I do that?


This item appears to have a DC input jack on the front. Bring it to your local Radioshack and they can get you a replacement adapter with the right plug and voltage.

Feb 26, 2010 | Power Center Jumpstart 11-411

Not finding what you are looking for?
Power Center Jumpstart 11-411 Logo

2,036 people viewed this question

Ask a Question

Usually answered in minutes!

Top TREND Vehicle Parts & Accessories Experts

Lawrence Oravetz

Level 3 Expert

8870 Answers

ray gallant

Level 3 Expert

41087 Answers

17 SOUTH INDUSTRIES
17 SOUTH INDUSTRIES

Level 2 Expert

166 Answers

Are you a TREND Vehicle Part and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...