2 Answers

Pressure setting of series 90 pumps

Hi, this is chandrakant from india. i am working for Schlumberger asia services ltd. as mechanic. we are user of sauer sundstrand pump . we have a problem with one series 90 pump, we want to set a pressure rating we are getting now 2000 psi and we wnt to increase it up to 3000 psi. is it possible ? pls guide me.
thanks

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Well, first you have to remember that your charge pressure is about 10% of the setting pressure, I mean if your main pressure is 2000 psi, then your charge pressure must be set at not lower then 200 psi in idle (650 rpm).
To increase pressure, take a 15/16 wrench and 5/16 allen wrench, on top of pump, at the side of charge filter block, you will see two multifunctional valves, one for port M1 and one for port M2 ( ports "A" and "B")
Remove hoses from such ports underneath the pump and plug them, then with engine in idle, with wrench 15/16 brake lose the top set screw nut of the multifunctional valve, slowly turn set screw with 5/16 allen wrench 1/2 a turn cw, this must increase your pressure about 500 psi, so from 2000 to 2500 psi, do this with both multifunctional valves.
Double check your pressure by stroking manually these pump.
You should increase your charge pressure also, remember 10% of your desired pressure.
main pressure 3000 psi
Charge pressure 300 psi
If you look your pump from behind, at your right hand,little above next to port M2, you will find another set screw with a big nut.
With a 1 1/4 wrench or 1 1//8 wrench, sorry cant remember the right size at this moment, brake lose such nut and turn 1/2 way in set scrwe with wrench 1/2 of an inch. this will increase your charge pressure

Posted on Apr 22, 2009

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 3 Answers

Yes 90 series pumps will run pretty close to 6000 psi. there are cross port reliefs built into the endcap of the pump and usually a POR valve as well. so the POR should be set at 3000, the cross ports in the pump should be set higher than this. There may also be a "transmission block" which is a seperate block with hot oil shuttle and cross port reliefs. Make sure these reliefs are also set higher than the POR valve in the pump. There may also be cross port reliefs in the motor. These too must be set higher than the POR valve in the pump. If you system overheats after increasing the pressure setting of the POR valve, you are probably loosing oil across one of the cross port relief valves.
Please visit http://hansonhydraulics.blogspot.com for more information. I** If am electric motor is being used to drive this pump, be sure you have sufficient horse power for this increased load. **

Posted on Mar 15, 2009

×

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Where can I buy Polaris ATV in Indore?


Polaris India has established its dealership across India. You can purchase Polaris ATV in Indore too, address is given below-

Mycar Indore Pvt.Ltd
15/1/8 & 15/1/15, Pipliya Kumar
Mangal Compound Near- Mittal Tol Kanta, Ring Road
Dewas Naka-Indore
Contact Person : Lokesh Sharma
Phone : 97550 95589
Mobile No : 97550 95599

Mar 08, 2014 | Polaris ATV

1 Answer

Where to buy Polaris ATVs in Kolkata?


Polaris India has established its dealership across India. You can purchase Polaris ATV in Kolkata too, address is given below-

Address: OSL Powersports Pvt Ltd (Showroom Address) G/4 kazi Nazrul Islam Sarani, Raghunathpur, VIP Road Opp: VIP Big Bazaar, Kolkata

Contact Person : Ms Sampa Roy
Phone : 033 6540 3969
Mobile No : 801 32 99999
Email: oslpolaris@oslgroup.co.i

Feb 28, 2014 | Polaris ATV

1 Answer

Grundfos pump


Louise, since there is several different types and models of Grundfos pumps it would be hard to answer your question. To possible point you in the right direction below are a few links to where you can find some PDF documentation about a popular Grundfos pump the MQ series and direct link to the manufactures "Service Support".

Service support
Grundfos MQ Series Pumps

Feb 07, 2014 | Fountains & Ponds

1 Answer

I have a pressure booster pump installed which turns on automatically when we open the tap and turns off by itself when we close the tap, but when power goes and comes back(common in india), the pump will...


Check to see if the output pipe has water in it when the pump swutches off the pump needs to be primed at all time what we normally find cases like this is the pump is higher than the supply or there is an air pocket on the output where the pressure sensor is

Dec 16, 2013 | Grundfos MQ3-35 3/4 HP Pressure Booster...

1 Answer

Makes lots of noise, started overnight, it was not gradual. Still works,maintains pressure and stars and stops, but very lot. Made sure all the air was out.Not vibrating or overheating.Sounds mechanical


Hi tim
Sounds to me like you have bad bearings in the motor...this will cause it to be noisy and run hot.
Replace your bearings in the motor and that should solve your problem
Please take time to rate me
Bud

Mar 16, 2013 | Grundfos MQ3-35 3/4 HP Pressure Booster...

1 Answer

Hi there, what should the tank pressure be , please? The custemor says that the pump keeps on hunting(stop/starts all the time)


set at what ever the cut out on the pressure regulator is set at- if set to cut off[out]at 50 will pressurize tank to 50 and stop pump- will come on when flow brings pressure down and what ever pressure on is set at --if short cycling -bad regulator -set wrong- air bladder bad in tank-motor overheating -binding [[[

Jun 11, 2010 | Grundfos MQ3-45 1 HP Pressure Booster...

2 Answers

Charge pressure drops to zero when hot and grouls.Where is the charge pressure set? Jack


What is the model number and brand of your pump? Your description is a classic statement when hydros (your pump and motor) are failing. You can try charge pressure adj to make it work better. Model number will tell me where to direct you.

Mar 18, 2010 | Danfoss Sundstrand-sauer-danfoss...

1 Answer

Should you have charge pump pressure when unit is engaged 25-2012model 12-xd-31981 ser. what should charge pump pressure be


Anytime the pump is running, there should be charge pump pressure present. When the pump is in nuetral, the hot oil shuttle will usually block flow, so the the charge pump builds up pressure untill the charge pump relief opens up, the pressure setting this occurs at depends on the what the OEM wanted. When the pump strokes up, there is a pressure differential between the two work ports, which shifts the hot oil shuttle spool, allowing oil to flow across the hot oil shuttle relief valve which will have a lower setting than the charge pump relief. So in Nuetral you will generally have a higher charge pump pressure and when on stroke, you will see charge pump pressure drop 50 to 100 psi.
Visit http://hansonhydraulics.blogspot.com any time for more information.

Mar 10, 2009 | Danfoss Sundstrand-sauer-danfoss...

Not finding what you are looking for?
Danfoss Sundstrand-sauer-danfoss Sundstrand Hydraulic Pump Logo

1,892 people viewed this question

Ask a Question

Usually answered in minutes!

Top Danfoss Fountains & Ponds Experts

yadayada
yadayada

Level 3 Expert

61017 Answers

Tom Chichester

Level 3 Expert

24581 Answers

MarK

Level 1 Expert

32 Answers

Are you a Danfoss Fountain and Pond Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...