Pilot wont stay lite

The pilot will light, but once i trun to on the pilot goes out. What do i do?????
cold in vegas please help!!!!!

Posted by on

  • Don Berry May 11, 2010

    Does it go out when you turn the knob on the gas valve to the "on" position or does it go out when you turn on the furnace with the thermostat? I would like to help:)

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 2,976 Answers

You either have a bad thermocouple or you need to reset the burner control.

Posted on Feb 05, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Raypak problem, Pilot is lit, can jump TH to TH to lite, goes out when jumper is removed.


check how many millivolts the pilot is generating. if pilot stay lit and burners wont fire u have a problem with one of the safties, lose wire connection, tstat control

May 28, 2013 | Raypak Pool & Spa

1 Answer

My mr heater wont stay light unless its above 3. It only stays on about 5 min then pilot goes out. It is gas heater. What's wrong with my heater?


Theres a thermostat inside, if its too cold and not warming up the thermostat enough it will shut off because it thinks there is a problem.

Feb 07, 2013 | Heating & Cooling

1 Answer

Teledyne laars xe pool and spa heater


look inside on panel directions if not turn to pilot setting hold down button light under where small silver line goes under while holding down button when lit keep holding for about a minute then turn to on should stay lit if wont stay lit need new pilot generator

Jun 09, 2012 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

My pilot light is weak and won't stay lite.


try cleaning the pilot light jet, usually gets dust etc inside it. clean it with a pin. but remember do not mess with gas appliances if you are not confident enough. as being cold will be the least of your worries lol

Feb 16, 2012 | Heating & Cooling

1 Answer

I light the piuolot button and when i let go of the pilot button the pilot goes out does not light burner wont stay lit


When you light the pilot lite you have to hold the button down until it gets the element hot enough to stay lit. If you hold down the button and lite the pilot and let it go right away it will go out. What to do is hold down the button and lite the pilot and continue to hold the buttn down for about 45 seconds to a minute then let it up very slowly and you will see if it is going to go out by the flame getting smaller as you let up on the button. If it does start to get smaller conitnue to hold it again for a few seconds and repeat the process of letting it up slowly. when the control element gets to the right temperature it will stay lit then turn your valve to "ON" and the fire will start up and continue to heat the water.

Mar 15, 2011 | RELIANCE ELECTRIC WATER HEATER

2 Answers

Why does pilot light turns on gas burner only to have it go out about 10 seconds later? 30 to 40 sec later repeats,without lighting. What is problem? once in awhile, it will light..not often. The burner...


Hello
Sounds like the thermocouple is going bad.The thermocouple is a thin tube that runs from the pilot lite to the gas valve.
What it does is it sences the heat from the pilot lite and keeps the gas valve open to allow the pilot to stay on.
This can be easily repaird by shutting off power and gas to your heater and removeing the thermocouple from the gas valve,then unclip or unscrew it from the pilot lite area.
Any plumbing supply store or home depot or lowes should have these.

Once you get a new one,install to gas valve and pilot lite area then turn on power and gas to heater and follow pilot lighting procedure,you may need to hold gas on for 60 seconds.

Here is a picture of the thermocouple so you know what to look for.


http://thermocatalytic.com/Thermocouple.JPG
http://homerepairgeek.com/wp-content/uploads/2010/12/furnace-thermocouple.jpg

Feb 10, 2011 | Honeywell Programmable Thermostat Heater

1 Answer

It wont lite, how do you lite the pilot, where is it located, do you have a manual i have a coleman presidental 3 furnace


There is a window directly above the gas control valve. Either a spring held latch or a screw off cover need to be removed to access the pilot. To light the pilot, turn the knob to pilot and hold down while lighting pilot. The pilot in straight back inside the hole about 10 inches. Use a long fireplace match or rig a wire to hold the match. Once the pilot lights, hold the control knob down for about 30 secs., if it stays lit after release, turn to "On" and operate normally.

Dec 13, 2009 | Tools & Hardware - Others

1 Answer

Pilots lites , holds ok for minutes,but once move


Hello KJGreen, It sounds, based on your description, as though the thermocouple is faulty and should be replaced. If the pilot light stays lit and you've left it on for several minutes before turning the knob on to light the log set, then that indicates that the thermocouple is bad.

The thermocouple is a safety device (heat sensor) designed to stop the flow of gas to the burner in the event the gas flame goes out and the pilot goes out. The sensor will only allow the gas valve to open once it has reached the preset temperature.

To confirm that the thermocouple is defective, I would light the pilot light and allow it to remain lit for up to 10 minutes before I attempted to turn on the log burner. If, after 10 minutes, the log burner still won't stay lit, then you know that the thermocouple needs to be replaced. Otherwise, the burner should light, since after 10 minutes, the sensor should be hot enough to signal the gas valve to open.

If you are going to have this replaced, please make sure you use only an approved supplier, since an incorrect replacement part could cause an unwelcome malfunction of the gas log burner. Safety should be primary when dealing with open flame burners.

Hope you find this Very Helpful and best regards!

Nov 23, 2009 | Vanguard International Infra Red - Large...

2 Answers

Laars Lite 2 LG - pilot light will not stay lit. As long as you hold down the pilot light once it is lit it stays lit but when I turn the nob to the "on" position (release the pilot light button) the flame...


It sounds like a thermocouple has gone bad. this is a very common problem with gas powered things ie; water heaters, furnaces, hot tubs. The telltale sign is when you release the pilot light button it won't stay lit. This is a safety feature and is relatively inexpensive and easy to repair.

Aug 08, 2009 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Gas furnace wont stay lite


I'm a little confused by your terminology. You are saying you have a pilot lite and electric heat strips? Are you possibly meaning burners? Is the heater running for 2 hours straight without shutting off? how cold is it there? Lastly what temperature do you have the thermostat set at and how close does it get to the temp. before it shuts off?

Dec 16, 2007 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

105 people viewed this question

Ask a Question

Usually answered in minutes!

Top Coleman Heating & Cooling Experts

Bill Long

Level 3 Expert

587 Answers

paulcarew

Level 3 Expert

2190 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Are you a Coleman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...