SOURCE: nuova simonelli appia 1 ....pump will not stop pumping so tank fu
Your level probe is on the right hand side plate of the boiler, normally with a red wire leading to it.
I would take the probe out (spanner reqd, obv. with no pressure in the boiler) and clean it with wire wool.Scale often causes the probes to malfunction.
Then make sure when you refit the probe, the part of the probe in the boiler faces down.
SOURCE: Need repair service in Denver, CO
Call Maric Beverage Systems they are very knowageable & the best service company in my opinion on Nuova Simonelli as well as all the others. 719-380-1610
SOURCE: mac cup V commercial Nuova Simonelli will not ****
First check the reset thermostat on the right side of the boiler below the level probe, make sure there is water in the boiler before resetting.
SOURCE: My Nuova Simonelli Mac digit pushes steam out of the group
The metering jet on the top of the boiler is blocked.
SOURCE: I'm getting no crema from my Nuova Simonelli Mac
Pressure pump is not working or can not produce 9 bar pressure.
Or the coffee is less tha 7 gr.
Or the coffee is grinded too thick.