Question about Computers & Internet

Open Question

How do i fix S.30 error code on a vaillant ecotec 24

Hot water works fine but no heating. Shows S.30 and if I hold in + - heating will come on for about 10 mins then go off.

Posted by on

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

zeusfaber
  • 247 Answers

SOURCE: Vaillant Ecotec combi boiler -

David,

The fact that you're getting a little burst of domestic hot water suggests that the boiler is capable of circulating hot primary loop water through the heat exchanger, but doesn't necessarily do so when it needs to.

What seems to be lacking is a recognition that domestic hot water is now being drawn off, and that the boiler needs to fire up and divert the primary flow through the heat exchanger.

A good place to start might be the flow switch (usually in the bottom of the boiler, where the cold water supply comes in) or the electrical connections to it.

A.

Posted on Oct 07, 2008

  • 44 Answers

SOURCE: heating, but no hot water on a vaillant turbomax 28 combi

the problem is the diverter valve unit, source a corgi engineer to fit new one, cost for valve approx 80 quid +fitting

Kindly

Richie

Posted on Dec 16, 2008

  • 1 Answer

SOURCE: Vaillant boiler - heating OK, but no hot water.

Most likey problem is the diverter valve, not energising fully. This in turn will not move the little plastic lever arm that actuates the microswitch on the side, sending the signal to ignite.

You can buy a diaghram kit from most local plumb centres, you need to replace the diaghram and seals, don't forget the silicon grease to ensure the plunger doesnt stick. Kits less than a tenner.

You should have noticed before it stopped working completely the water had reduced in temperature before the weeks it failed.

To make sure it is a diverter valve fault, depress the microswitch if you can, when the hot water is flowing and hey presto the demand for hot water light should shine.

Posted on Apr 26, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Vaillant ecotec plus 824 problems


The Symbols should be there whenever the boiler is in use, it confirms the pump is running and the gas valve is open...i.e firing.
the pump overrun may come on after a firing to dissipate excess heat and is what it says, i.e the pump continues to run to keep the hot water moving to prevent the boiler from getting noisey. Sometimes you may see a radiator symbol which means the boiler is doing a 'heating' cycle as against hot water.

Nov 20, 2013 | Computers & Internet

1 Answer

My vaillant ecoTec plus shows F49 , new vrt 360


F.49 eBUS undervoltage Short circuit on eBUS, overload on eBUS or two power sources on eBUS with different polarity F.61 Gas-valve control defective Short circuit/earth (ground) leak F.49 eBUS undervoltage Short circuit on eBUS, overload on eBUS or two power sources on eBUS with different polarity F.61 Gas-valve control defective Short circuit/earth (ground) leak i pasted the answer below hope it worked

Aug 02, 2010 | Heating & Cooling

1 Answer

F22 error/ low pressure


F.22 Dry fire Too little water in the appliance, water pressure sensor defective,
cable to pump or water sensor defective, pump blocked or defective,
pump output too low

May 11, 2010 | Heating & Cooling

2 Answers

Lost my user manual for the vaillant boiler ecotec plus 824 R1


try to enter here all informations and you can find the manual: http://instructions-manuals.com/search.php?cmarque=VALLIANT%20&modele=ECOTEC%20PLUS%20824

Oct 27, 2009 | KDS Valiant 6380iPTD-01 Notebook

2 Answers

Vaillant boiler no heating or hot water


refere to manual check for override switch loss of pressure no problem re-pressurise and check for leak top of rad valve good place to start

Oct 10, 2009 | Water Heaters

1 Answer

Heating, but no hot water on a vaillant turbomax 28 combi


the problem is the diverter valve unit, source a corgi engineer to fit new one, cost for valve approx 80 quid +fitting

Kindly

Richie

Dec 15, 2008 | Water Heaters

1 Answer

Vaillant Ecotec combi boiler - radiators working but no hot water flow to taps


David,

The fact that you're getting a little burst of domestic hot water suggests that the boiler is capable of circulating hot primary loop water through the heat exchanger, but doesn't necessarily do so when it needs to.

What seems to be lacking is a recognition that domestic hot water is now being drawn off, and that the boiler needs to fire up and divert the primary flow through the heat exchanger.

A good place to start might be the flow switch (usually in the bottom of the boiler, where the cold water supply comes in) or the electrical connections to it.

A.

Oct 05, 2008 | Heating & Cooling

Not finding what you are looking for?
Computers & Internet Logo

Related Topics:

126 people viewed this question

Ask a Question

Usually answered in minutes!

Top Computers & Internet Experts

Doctor PC
Doctor PC

Level 3 Expert

7733 Answers

kakima

Level 3 Expert

102366 Answers

David Payne
David Payne

Level 3 Expert

14161 Answers

Are you a Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...