Question about Konica Minolta Minolta 7130 Laser Printer Toner Cartridges

1 Answer

Replace pc What is this error that is occuring in the machine control panel?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Konica Minolta Master
  • 1,297 Answers

Replace your Photoconductor(OPC Drum),before replacing must be reset the drum counter.

Posted on Jan 30, 2013

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My ricoh aficio MP3351 machine has a error problem SC672, plz kindly tell me what i can do???


SC672 occured when controller-to-operation panel communication error at startup After powering on the machine, the communication circuit between the controller and the operation panel is not opened, or communication with controller is interrupted after a normal startup.

.Controller stalled
.Controller board installed
incorrectly
.Controller board defective
.Operation panel connector
loose or defective

Make sure that the MBU is seated correctly. If not, SC672 occurs look at the picture to see what im talking about.

mbu-mpgtdnp1q1icgjyji5ew5m4c-1-0.png

Sep 29, 2017 | Ricoh Office Equipment & Supplies

Tip

Kenmore Elite, Whirlpool Duet, Maytag Epic series Error Codes


The following are common error codes, with general definitions, associated with Whirlpool Duet series, Duet Sport series, Steam series, Kenmore Elite series and Maytag Epic series FRONT LOADING washing machines. The error codes pertaining to the washer you have, will be determined by the specific model number. All error codes are listed in the technical data sheet associated with the appliance.

F/H/F20 - NO WATER DETECT ERROR. No water detected entering the machine, or the pressure switch has not tripped after 6 minutes.

F01/F14 - EEPROM ERROR. Communication problem between the Central Control Unit (CCU) and Motor Control Unit (MCU), or inability to read the EEPROM data on the CCU.

F02/F21 - LONG DRAIN. Commonly associated with a drain pump failure or clog in the drainage system. Occurs when the drain time exceeds 8 minutes.

F03 - HEATER SHORT CIRCUIT TO GROUND. Occurs if there is a short circuit to ground detect on the heater.

F05/F24 - WATER TEMPERATURE SENSOR ERROR. Associated with NTC sensor out of range or heating circuit failure.

F06/F25 - DRIVE MOTOR TACHOMETER ERROR/STEAMER DEFECT. Occurs when the motor speed cannot be detected by either the MCU or the CCU. Or, for steam models, the steamer temperature has not reached the correct value.

F07/F15 - MOTOR CONTROL UNIT ERROR. An internal failure with the Motor Control Unit has been detected by the Central Control Unit.

F09/F27 - OVERFLOW CONDITION. Occurs when the Overflow Contact on the Pressure Switch is closed for more than 60 seconds. When an overflow condition is generated, the door remains locked and the drain pump will run constantly. Pressing PAUSE/CANCEL will clear the display, but often will not shut off the pump. UNPLUG washer to service.

F10/F31 - MOTOR CONTROL UNIT HEAT SINK TRIP. Occurs when the thermal protector on the MCU gets too hot.

F11/F28 - SERIAL COMMUNICATIONS ERROR/MOTOR CONTROL UNIT ERROR. Caused by either a communications problem between the Central Control Unit and Motor Control Unit, or Motor Control Unit internal failure.

F13/F30 - DISPENSER CIRCUIT ERROR. Occurs when the dispenser motor is not in the proper position.

Fdl/F22 - DOOR LOCK ERROR. Occurs when the door fails to latch after 6 attempts.

F23 - HEATER FAILURE. Occurs when the water temperature increase is less than 86 degrees F during the first 40 minutes.

F26 - DOOR SWITCH ERROR. Occurs when the door has not be opened for three consecutive cycles. Or, if the door switch remains open for more than 5 seconds while the door is locked.

Fdu/F29 - DOOR UNLOCK ERROR. Occurs when the door fails to unlock after 6 attempts.

F32 - PRESSURE SWITCH FAILURE. Occurs when no electrical supply from the CCU to the pressure switch is detected. Or, if the pressure switch contacts are worn out.

F33 - PUMP DRIVE SYSTEM ERROR. Occurs when the connection between the pump and the Central Control Unit (CCU) is lost.

F34 - UNLOAD. This failure is only for information purposes and is displayed in the error log history during diagnostics. Occurs when a load was detected in the drum during a clean cycle and the cycle had to be interrupted.

F35 - ANALOG PRESSURE SWITCH FAILURE. Occurs when there is a malfunction of the steamer component detected by the steamer electronic control board.

F42 - MOTOR CONTROL UNIT ERROR, REPETITIVE UNDERVOLTAGE. Occurs when 4 under voltage conditions are detected by the MCU during the wash cycle.

F61 - STEAMER COMMUNICATION FAILURE. Occurs when incorrect communication is detected between the CCU and steamer electronic board. Error should reset after running diagnostics.

F62 - STEAMER ELECTRONIC BOARD RELAY ERROR. Occurs when one of the steamer board relays (K1, K2, K3, K4) fails. Error should reset after running diagnostics.

F63 - TOTAL STEAMER FAILURE. Occurs when the steamer will no longer function and needs to be replaced.

F64 - STEAMER INLET VALVE FAILURE. Occurs when the steamer valve or flush valve becomes blocked. Error should reset after running diagnostics.

F65 - STEAMER TIMEOUT. Occurs when there is no communication between the CCU and Steamer Electronic Board. Error should reset after running diagnostics.

F70 - CENTRAL CONTROL UNIT (CCU) HEARTBEAT FAILURE. Occurs when no communication data is detected from the CCU to the front panel user interface.

F71 - USER INTERFACE HEARTBEAT FAILURE. Occurs in conjunction with F70 error due to no communications detected from the User Interface to the CCU.

F99 - NOT SUPPORTED. Mismatch of the User Interface and Central Control Unit (CCU). Or, corrupted EEPROM.

rL - WASH LOAD DETECTED INSIDE WASH TUB DURING CLEAN CYCLE. Detects any garments (by weight) that may be left inside the wash tub during a clean cycle. NOTE: Wash tub is to remain empty during a Clean Cycle.

Sd/SUD - SUDS LOCK ERROR. Occurs when too much detergent is used. Or, occurs in conjunction with F02/F21 error (Long Drain) due to obstructions in drain cycle.

The first step in troubleshooting any error code is to press PAUSE/CANCEL twice to clear, and verify your installation. Make sure the water inlet valves are turned on and connected correctly. If the error code remains, UNPLUG the washer for AT LEAST 30 minutes in an attempt to reset the Central Control Unit. In many cases a simple CCU reset will correct any momentary glitches or erroneous errors. If the error returns following a CCU reset, a legitimate error condition exists and must be corrected in order to return the appliance to normal operation. For more specific information and troubleshooting advice on how to remedy most problems, refer to the technical data sheet.

NOTE: EACH ONE OF THESE APPLIANCES COME WITH A TECHNICAL DATA SHEET INSIDE. THIS IS THE SAME SHEET AN APPLIANCE REPAIRMAN WILL REFERENCE ON A SERVICE CALL. REFER TO THE TECH SHEET FOR MORE DETAILED TROUBLESHOOTING INFORMATION.

The tech sheet contains troubleshooting data, wiring diagrams, diagnostics procedures, component illustrations and all error code definitions.



To access, you will need to remove the lower toe panel directly below the door. The access screws are located under the bottom front edge of the panel. You may have to prop the two front feet of the washer up for better access to the screws (a 2x4 works well for this). With the screws removed, the panel should drop down, and come off. If the tech sheet isn't directly behind the toe panel, it will be affixed to one of the interior cabinet walls.
It is recommended that the tech sheet be placed back inside the appliance when repairs are completed in order avoid losing and to keep this pertinent info for future use.

on Apr 20, 2011 | Washing Machines

1 Answer

Hi!Can you help me resolving error code 092-315 for xerox7225?


Can you verify the error code? 092-315 does not appear in the error code site. See link below

How To Search for a Fault Code WC7220 / WC7225 Fault Code Page
To search on a fault code, enter one code at a time. The codes will be displayed on the Touch Screen.
Fault code format: A 3-digit number, followed by a 3-digit number. For example, 010-352.
Viewing Fault and Alert Messages on the Control Panel
When a fault or alert condition occurs, a message will be displayed on the Control Panel to inform you of the problem. Alert messages inform you about printer conditions, such as low supplies or open doors, that require your attention. Fault messages warn you about printer conditions that prevent the printer from printing or degrade printing performance. If more than one condition occurs, only one displays on the Control Panel.
To view a complete list of active fault and alert messages:
  1. Press the [Machine Status] button on the Control Panel.
  2. Select the [Active Messages] tab.
  3. Use the Down arrow and select [Faults], [Alerts], or [Faults & Alerts].
  4. To view details, select a fault or alert.
Viewing the Fault History on the Control Panel
When faults occur, they are logged in to a fault history file by date, time, and fault code. Use this list to identify trends and resolve problems.
To view the fault history:
  1. Press the [Machine Status] button on the Control Panel.
  2. Select the [Active Messages] tab.
  3. Select [Fault History]. The screen displays the number, date, time, and image count for each fault code.
The following table represents the system area as represented by the first 3-digits of the fault code:
Chain Description 303 Communications Error 305 Duplex Automatic Document Feeder (DADF) 310 Fusing 312, 313 Finisher 371 - 375 Paper Tray Feed 377 Sensor / Interlock Fault 391 Drum Cartridge / Waste Toner
http://www.support.xerox.com/support/workcentre-7220-7225/support/enus.html

Mar 07, 2016 | Xerox Office Equipment & Supplies

1 Answer

Error E 732 0001


E732-0001 Error Code: Reader Controller PCB is faulty

[ Case in the field ]
Description
E732-0001 can be displayed when a communication error occurs.
Cause
In the field, this symptom occurred because the Reader Controller PCB was faulty.
Field Remedy
1. Make sure that the connector between the host machine and the reader unit is securely fitted.
2. Make sure that the connectors on the Reader Controller PCB are securely fitted or there is no pinched cables.
3. Remove and insert the Main Controller PCB (Sub) from the Main Controller PCB (Main). If the symptom still recurs, go to the Step 4.
4. Replace the Reader Controller PCB with a new one.


E732-0001 Error Code: locks up during copying

E732-0001 can be displayed when a reader communication error occurs.
Cause
As a result of inspection, it was found that this symptom occurred because of poor soldering of J1302-34pin on the Main Controller PCB (Sub).
Field Remedy
1. Make sure that the connectors are securely fitted between J1302 on the Main Controller PCB (Sub) and J502 on the Reader Controller PCB and that
there is no pinched cable.
2. If no problem is found, replace the Main Controller PCB (Sub) with a new one.


E732-0001 Error Code: Because of poor contact of SDRAM

Description
E732-0001 indicates that a reader communication error has occurred.
Field Remedy
As a result of inspection, it was found that this symptom occurred because the SDRAM was not securely fitted on the Main Controller PCB. So, remove
and insert the SDRAM once again.

Sep 26, 2013 | Canon imageRUNNER C3200 Copier

3 Answers

My computor says it has been interrupted it does diagonostic says error 303


If you want to know what this is the error code is related to

Click start control panel administrative tools computer management then select event viewer this may vary depending on what operating system you have


extend the events there you will see errors in red you will no what exactly what the error was and at what time it occured

or click start type in event viewer press ENTER

you might be able work your way through the problem

Hope it helps.

Nov 29, 2012 | HP TouchSmart IQ770 PC Desktop

1 Answer

I have canon c2620n and when i turn it on give E 732-0001 i need help pleas


E732-0001 Error Code: Reader Controller PCB is faulty

[ Case in the field ]
Description
E732-0001 can be displayed when a communication error occurs.
Cause
In the field, this symptom occurred because the Reader Controller PCB was faulty.
Field Remedy
1. Make sure that the connector between the host machine and the reader unit is securely fitted.
2. Make sure that the connectors on the Reader Controller PCB are securely fitted or there is no pinched cables.
3. Remove and insert the Main Controller PCB (Sub) from the Main Controller PCB (Main). If the symptom still recurs, go to the Step 4.
4. Replace the Reader Controller PCB with a new one.


E732-0001 Error Code: locks up during copying

E732-0001 can be displayed when a reader communication error occurs.
Cause
As a result of inspection, it was found that this symptom occurred because of poor soldering of J1302-34pin on the Main Controller PCB (Sub).
Field Remedy
1. Make sure that the connectors are securely fitted between J1302 on the Main Controller PCB (Sub) and J502 on the Reader Controller PCB and that
there is no pinched cable.
2. If no problem is found, replace the Main Controller PCB (Sub) with a new one.


E732-0001 Error Code: Because of poor contact of SDRAM

Description
E732-0001 indicates that a reader communication error has occurred.
Field Remedy
As a result of inspection, it was found that this symptom occurred because the SDRAM was not securely fitted on the Main Controller PCB. So, remove
and insert the SDRAM once again.

Jan 31, 2011 | Canon imageRUNNER C3200 Copier

2 Answers

Printer not detected when plugged into USB port. Tried multiple PC's and cables with same result. I get an "I/O Card Not Ready" error when I print diagnostic. I also just noticed that my LCD display has...


First I would recommend unplugging the machine.
Then reseat the formatter assembly.

The "I/O card not ready" is the network card which is plugged-in to the formatter. That card is for networking purposes. it will display not ready if their is not a cat5 cable plugged into it. On the first page of the configureation you should see the last 3 error codes. usually located on the left hand side half way down. if you are see 49X.XX errors you probably need to replace the formatter.
96a8c19.gif


However the control panel blanking out could be several options:

First I would make sure it's not plugged into a surge protector. (HP recommends NOT to have any machine plugged into a surge protector),
Try a different outlet. if that fails that could revert back to either a bad control panel or the DC Controller. Below is a picture of the DC Controller
2805da6.gif

Oct 19, 2010 | HP LaserJet 3600n Printer

1 Answer

Shows f70 and the door won't open


First there is a way to open the locked door and get your clothes out. On this model of Kenmore front load washer you can manually release the door lock.Unplug the washer from power. Remove the front lower inspection panel (see the first image), and reach up to the bottom of the door lock and pull down on the small teardrop tab. This will unlock the door lock and allow you to get the clothes out.
The F70 error is a control failure that occurs when a signal from the main control to the interface (touch pad) is not detected.
This can be caused by a loose harness connection at the interface or main control. The image below will show how to remove the top so you can check for lose connections. Be sure to unplug the washer first.
The F70 is an internal control problem. It can be caused by a failed central control board or an interface problem. The way to determine which part is bad when the error occurs is as follows:
  • If the error occurs when the machine is running then the problem is the interface.
  • If the error occurs when the washer is not running the problem is the central control unit.
The control and the interface are available from the following link: Sears PartsDirect . Use your model number to order the correct part for your washer.

Aug 18, 2010 | Kenmore HE2 Plus Front Load Washer

2 Answers

E-000602-0003 error is occurring when machine powered on


the error E602 is Hard disk error and you can clear it in
Service Mode and Making Selections
1) Press the User Mode key ‘ ’ .
2) Press ‘2’ and ‘8’ on the keypad at the same time.
3) Press the User Mode key ‘ ’ on the control panel.
In response, the following Initial screen will appear:
To reset the error, execute the following in service mode:
COPIER>FUNCTION>CLEAR>ERR.

else you need to replace your machines hard disk

Jul 10, 2009 | Canon imageRUNNER 3300 All-In-One Laser...

1 Answer

Goggle Desk


can you uninstall your google desktop from add remove in control panel

Jan 19, 2009 | E-Machines eMachines Desktop PC

Not finding what you are looking for?
Konica Minolta Minolta 7130 Laser Printer Toner Cartridges Logo

19 people viewed this question

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman  J Weimar Jr
Norman J Weimar Jr

Level 3 Expert

6161 Answers

Adorjani Laszlo

Level 3 Expert

1297 Answers

Ben
Ben

Level 2 Expert

108 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...