Question about Goodman GDS80904BNA Open Flame Heater

Open Question

Goodman GMH950453BXAB Flame sensor - Goodman GDS80904BNA Open Flame Heater

Posted by Anonymous on

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya Repairman can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repair professionals here in the US.
click here to Talk to a Repairman (only for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
Therinnaiguy
  • 1420 Answers

SOURCE: flame sensor on a goodman heater

The flame sensor will be located either left or right of the burners and there will be only one wire leading to it. It is positioned so the flame hits it last. So if you watch your flame spread, it will be on the side last to see flame.

Posted on Nov 11, 2008

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Goodman furnace furnace starts,flames start and shuts off after 10 sec. Replaced flame sensor still have same problem


if flame sensor is new, the board may not be properly recieving currrent from flame sensor to keep burners on

Feb 05, 2014 | Goodman Heating & Cooling

1 Answer

I have a goodman propane furnace, model # GMPN080-4 that lights for about five seconds and then cuts off. It does this three times and then stops all together. Tried lightly sanding the flame sensor and it...


The goodman furnace will try and light three time before it faults out for safety reasons. Adjust the flame sensor so that it is closer to the flame or actually in the pilot flame. If the flame sensor is inside the pilot flame and still does not stay lit, your flame sensor is probably defective and should be replaced. You can get one at Ferguson's counter sales.

Dec 12, 2010 | Heating & Cooling

1 Answer

Goodman Dependable 92, ignitor and fan comes on for 3 seconds, furnance does not turn on. Goes through 3-4 cycles, then shuts down furnance. If it is the flame sensor, where can one buy parts?


Do the burners come on? If so then yes it probably is the flame sensor if not then there is another issue not the flame sensor. The flame sensor could just be dirty take the flame sensor out and clean it with a piece of emery cloth or lite sand paper and put it back in and this should get the burners to stay on.

Feb 05, 2010 | Goodman GMS90703BXA Heater

2 Answers

Goodman gmp075-3 gas furnace and the flame cycles for 4 sec


JUST SAND THE FLAME SENSOR LOCATED IN FRONT OF THE LAST GAS PORT.

Dec 02, 2009 | Goodman GMS90703BXA Heater

1 Answer

I have a Goodman GUPI100-5 pilot comes on but wont fire up.


Your flame sensor is measured in Millivolts not voltage. Is the flame spreading accross the burners at all? If it only ignites on one of the burners, you have debris blocking the flame spreader. Clean the burners and flame spreader bar. If you just as you say get a pilot, clean the flame rod.

Nov 24, 2008 | Goodman GMS90703BXA Heater

1 Answer

Flame sensor on a goodman heater


The flame sensor will be located either left or right of the burners and there will be only one wire leading to it. It is positioned so the flame hits it last. So if you watch your flame spread, it will be on the side last to see flame.

Nov 10, 2008 | Goodman GMS90703BXA Heater

1 Answer

Furance lights and goes out after ten seconds does this three times.bought a new flame sensor worked two days same thing again.goodman furnace


If it isnt the flame sensor make sure the furnace ground wire is hooked up.If the ground is bad it cant sense flame.

Oct 20, 2008 | Goodman Heating & Cooling

1 Answer

Goodman heating element does not light


The flame sensor is not sensing flame. Inspect the system as it is tying to start and see if the flames are traveling to all burners and hitting the sensor. If not, clean the burner flame rail (the trough the allows the flame to travel from one burner to the next) or if it is hitting the sensor, clean the sensor with steel wool and check all connections from the sensor to the control board.

Jan 20, 2008 | Goodman GMS90703BXA Heater

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

55 people viewed this question

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Paul Carew

Level 3 Expert

2887 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions