Question about Maytag HYE3658AY Electric Dryer

1 Answer

Dryer will not turn on

I have replaced the thermal fuse and thermostat and still no luck. door switch is good. checked continuity on fuse, thermostat, door sensor, and connecting wires.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 135 Answers

Make sure you have power to the unit. Check the start switch as well. Hope this helps!

Posted on Jan 27, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Dryer turns but no heat


Hi Mike
Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Bud

Oct 10, 2013 | Kenmore 64852 Electric Dryer

1 Answer

Our electric Samsung dryer is not working. There is power to it but the drum does not turn.


Hi dominicbraga
Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,then you do not have to tape the wires together as described above.
But do not trust the ohm meter all the time, because sometimes it will give a false positive that the fuse is ok when in reality it is faulty.
DO THE FOLLOWING TEST:
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
This test of the thermal fuses,thermistor,thermostat, will show if the thermal fuse,thermostat,thermister is really faulty or not.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
DO THE FOLLOWING: Remove the wires and tape them together and try to start the dryer.If the dryer starts then replace the fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on air fluff/no heat, and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up

Sep 26, 2011 | Dryers

1 Answer

My dryer wont turn on


Hi isiahtanner...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,then you do not have to tape the wires together as described above.
But do not trust the ohm meter all the time, because sometimes it will give a false positive that the fuse is ok when in reality it is faulty.
DO THE FOLLOWING TEST:
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
This test of the thermal fuses,thermistor,thermostat, will show if the thermal fuse,thermostat,thermister is really faulty or not.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
DO THE FOLLOWING: Remove the wires and tape them together and try to start the dryer.If the dryer starts then replace the fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on air fluff/no heat, and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up

Sep 26, 2011 | Dryers

1 Answer

My kenmore 70 series dryer wont turn on


Hi gcdozier....

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up

Sep 13, 2011 | Kenmore Dryers

1 Answer

I have a roper dryer model # RED444OVQ that won't start, door switch and thermal fuse check out ok


Hi mntcape...

When you check your thermals/thermostats,thermistors,ect, pull the wires off and hook them together and then try starting the dryer after each one you do this way.
Be sure not to touch any exposed wires or let them ground against the frame of the dryer
I just tested a thermal fuse the other day, tested good...was faulty.
You have checked some of the things below...
****************************************************************************************************************
Here are a few more things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up

Sep 13, 2011 | Dryers

1 Answer

No heat . heating element looks good no coils broke. replaced thermal fuse and themostat .now what?


Hi mikedissnts...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me

Sep 08, 2011 | Amana Dryers

1 Answer

I have an amana electric dryer. Will not heat up. i checked thermostat for continuity it is good. i checked the two thermal fuses for continuity they are good. I even jumped a wire accross all three...


Hi pitsburg69...
you have probably already checked some of these...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
Please take time to rate me

Sep 04, 2011 | Amana Dryers

1 Answer

My dryers is turning but not heating up to dry clothes. I have checked the breaker box. Still no luck. There are no error codes. What might be the problem?


Hi poplargrove...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuseremove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me

Aug 30, 2011 | Whirlpool Cabrio 7.0 Cu. Ft. Super...

1 Answer

My electric dryer turns on inside turns but no heat.


Hi seanfallan...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuseremove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me

Aug 19, 2011 | Whirlpool Dryers

2 Answers

Heating element stays on when dryer is off.


I would advise to inspect the high limit thermostat. this device may be defective. this will cause the element to continue to operate when the unit is off as well. If the thermostat is operating correctly, replace the timer.

Aug 12, 2009 | Maytag PYE2300AY Electric Dryer

Not finding what you are looking for?
Maytag HYE3658AY Electric Dryer Logo

Related Topics:

95 people viewed this question

Ask a Question

Usually answered in minutes!

Top Maytag Dryers Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3053 Answers

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Are you a Maytag Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...